Radiation Dose to the Lens Using Different Temporal Bone CT Scanning Protocols

被引:30
|
作者
Niu, Y. [1 ]
Wang, Z. [1 ]
Liu, Y. [1 ]
Liu, Z. [1 ]
Yao, V. [2 ]
机构
[1] Capital Med Univ, Dept Radiol, Beijing Tongren Hosp, Beijing 100730, Peoples R China
[2] Philips Healthcare, Beijing, Peoples R China
关键词
HIGH-RESOLUTION CT; COMPUTED-TOMOGRAPHY; PETROUS BONE;
D O I
10.3174/ajnr.A1807
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Temporal bone CT is performed frequently in clinical practice. At the same time, the eye lens are exposed to ionizing radiation without any useful diagnostic information delivered. Our aim was to investigate the radiation dose to the lens of the eye by using temporal bone CT scanning with different protocols. MATERIALS AND METHODS: Direct axial and coronal CT by using a conventional sequential scanning mode (140 kV, 220 mAs/section, 1.25-mm thickness, 1.25-mm increment, 16 x 0.625 mm collimation, the glabellomeatal line as a scanning baseline), a routine helical scanning mode (140 kV, 220 mAs/section, 0.315 pitch, 0.67-mm thickness, 0.33-mm increment, 16 X 0.625 collimation, the orbitomeatal line as a scanning baseline), and a modified helical scanning mode (acanthiomeatal line as a scanning baseline; other parameters, same as above) was performed on an exsomatized cadaveric head. CTDl(vol) and DLP were recorded for each scanning mode, and effective doses were calculated. Organ doses for the lens were measured with TLDs. RESULTS: When the sequential scanning mode was used, the gross effective dose was 1.21 mSv and the organ dose to the lens was 50.96 and 1.73 mGy, respectively, for direct axial and coronal imaging. The effective dose was 0.803 mSv in routine helical scanning, while the lens dose was 40.17 mGy. With the modified helical scanning mode, the effective dose was as same as that for the routine helical scanning, but the lens dose was reduced significantly to 10.33 mGy. CONCLUSIONS: The effective doses resulting from sequential axial and coronal scanning were 1.51 times higher than the dose from helical scanning, and the lens dose was 1.31 times higher. With the modified helical scanning mode, thinner section images could be used to reformat axial, coronal, and sagittal images with a further 74.3% reduction in lens dose beyond that achieved with the conventional helical protocol.
引用
收藏
页码:226 / 229
页数:4
相关论文
共 50 条
  • [1] Evaluation Of Coronary CT Scans Radiation Dose And Image Quality Using Different Scanning Protocols On a 256-slice CT Scanner
    Fareed, Ahmed M.
    Gaux, Jean Claude
    Pernes, Jean Marc
    Oraby, Mohamed
    Nasr, Gamila
    Maklady, Fathy
    Dupouy, Patrick
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (13) : B89 - B89
  • [2] Radiation dose to the lens from coronal CT scanning of the sinuses
    ZammitMaempel, I
    CLINICAL RADIOLOGY, 1996, 51 (02) : 151 - 151
  • [3] ALADA Dose Optimization in the Computed Tomography of the Temporal Bone: The Diagnostic Potential of Different Low-Dose CT Protocols
    Kofler, Barbara
    Jenetten, Laura
    Runge, Annette
    Degenhart, Gerald
    Fischer, Natalie
    Hoermann, Romed
    Steurer, Michael
    Widmann, Gerlig
    DIAGNOSTICS, 2021, 11 (10)
  • [4] RADIATION-DOSE TO THE LENS FROM CORONAL CT SCANNING OF THE SINUSES
    MACLENNAN, AC
    CLINICAL RADIOLOGY, 1995, 50 (04) : 265 - 267
  • [5] Radiation dose to the eye lens from coronal CT scanning of the sinuses
    Spencer, DH
    CLINICAL RADIOLOGY, 1996, 51 (09) : 666 - 666
  • [6] Comparison of two different GSI scanning protocols in head and neck CT angiography: Image quality and radiation dose
    Zhang, Tianle
    Zhao, Sai
    Liu, Yiwen
    Liu, Zhichao
    Ma, Zepeng
    Zuo, Ziwei
    Zhao, Yongxia
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2022, 30 (04) : 689 - 696
  • [7] Dose optimisation in paediatric CT examination: Assessment on current scanning protocols associated with radiation dose
    Abdulkadir, Muhammad Kabir
    Rahim, Nur Atikah Yusra Mat
    Mazlan, Nur Syazwani
    Daud, Norfataha Mohd
    Shuaib, Ibrahim Lutfi
    Osman, Noor Diyana
    RADIATION PHYSICS AND CHEMISTRY, 2020, 171
  • [8] Reduction in Lens Dose in Temporal Bone Computed Tomography by Modification of Scanning Plane
    Lee, T. F.
    Chu, C. Y.
    Sung, H. T.
    Leung, S. T.
    Leung, K. W.
    Kan, W. K.
    HONG KONG JOURNAL OF RADIOLOGY, 2016, 19 (02): : 91 - 95
  • [9] A Survey of Pediatric CT Protocols and Radiation Doses in South Korean Hospitals to Optimize the Radiation Dose for Pediatric CT Scanning
    Hwang, Jae-Yeon
    Do, Kyung-Hyun
    Yang, Dong Hyun
    Cho, Young Ah
    Yoon, Hye-Kyung
    Lee, Jin Seong
    Koo, Hyun Jung
    MEDICINE, 2015, 94 (50)
  • [10] Dose from kV cone beam CT to lens, breast and gonads for children using different standard protocols
    Assenholt, M. S.
    Hansen, R.
    Hansen, J.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S746 - S747