Experimental study on the influence of Peltier effect on the output performance of thermoelectric generator and deviation of maximum power point
被引:38
|
作者:
Wang, Jun
论文数: 0引用数: 0
h-index: 0
机构:
Jiangsu Univ, Sch Automot & Traff Engn, Zhenjiang 212013, Jiangsu, Peoples R ChinaJiangsu Univ, Sch Automot & Traff Engn, Zhenjiang 212013, Jiangsu, Peoples R China
Wang, Jun
[1
]
Cao, Peiguo
论文数: 0引用数: 0
h-index: 0
机构:
Jiangsu Univ, Sch Automot & Traff Engn, Zhenjiang 212013, Jiangsu, Peoples R ChinaJiangsu Univ, Sch Automot & Traff Engn, Zhenjiang 212013, Jiangsu, Peoples R China
Cao, Peiguo
[1
]
Li, Xingjun
论文数: 0引用数: 0
h-index: 0
机构:
Jiangsu Univ, Sch Automot & Traff Engn, Zhenjiang 212013, Jiangsu, Peoples R ChinaJiangsu Univ, Sch Automot & Traff Engn, Zhenjiang 212013, Jiangsu, Peoples R China
Li, Xingjun
[1
]
Song, Xiangxiang
论文数: 0引用数: 0
h-index: 0
机构:
Jiangsu Univ, Sch Automot & Traff Engn, Zhenjiang 212013, Jiangsu, Peoples R ChinaJiangsu Univ, Sch Automot & Traff Engn, Zhenjiang 212013, Jiangsu, Peoples R China
Song, Xiangxiang
[1
]
Zhao, Chuang
论文数: 0引用数: 0
h-index: 0
机构:
Kailong High Technol Co Ltd, Wuxi 214000, Jiangsu, Peoples R ChinaJiangsu Univ, Sch Automot & Traff Engn, Zhenjiang 212013, Jiangsu, Peoples R China
Zhao, Chuang
[2
]
Zhu, Lei
论文数: 0引用数: 0
h-index: 0
机构:
Kailong High Technol Co Ltd, Wuxi 214000, Jiangsu, Peoples R ChinaJiangsu Univ, Sch Automot & Traff Engn, Zhenjiang 212013, Jiangsu, Peoples R China
Zhu, Lei
[2
]
机构:
[1] Jiangsu Univ, Sch Automot & Traff Engn, Zhenjiang 212013, Jiangsu, Peoples R China
[2] Kailong High Technol Co Ltd, Wuxi 214000, Jiangsu, Peoples R China
Energy conversion;
Thermoelectric generator;
Peltier effect;
Maximum power point;
WASTE HEAT;
OPTIMIZATION;
DESIGN;
COOLER;
TRACKER;
SYSTEM;
MODEL;
SIZE;
D O I:
10.1016/j.enconman.2019.112074
中图分类号:
O414.1 [热力学];
学科分类号:
摘要:
Thermoelectric generator technology can convert heat into electricity based on Seebeck effect, but the Peltier effect cannot be neglected in the thermoelectric conversion process. In order to explore the influence of Peltier effect on the output performance of thermoelectric generator under the fixed heat transfer boundary conditions, an experimental system is set up. In the experiment, the hot side of the thermoelectric generator is heated by a thermostatic heater which can keep the heating temperature constant, and the cold side is cooled through the convective heat transfer with water. The effect of cooling water flow rate on the open-circuit voltage is first analyzed and the optimum cooling water flow rate is confirmed. Furthermore, the influence of Peltier effect on the cold side temperature and output performance of thermoelectric generator is investigated. The result shows that Peltier effect results in the less actual output power than the theoretical value and makes the maximum power point deviate from the point where the load resistance equals the internal resistance. Besides, as hot side temperature advances from 67 degrees C to 185 degrees C, the ratio of load resistance to internal resistance increases from 1.2 to 1.307 in the case of maximum output power.