摘要
The paper considers alternative engineering approaches to energy efficient cooling and heating systems. Traditional HVAC design considers systems to be continuous flow. With the robust control technologies available, we may need to think batch flow concepts to meet required part load operation efficiency and ventilation requirements. The need for greater cooling capacity is a significant problem for the office facilities designed in the 1960's. And having high internal computer system heat loads.
引用
收藏
页码:169 / 172
页数:4
相关论文
共 50 条
  • [1] Displacement ventilation and Variable Air Volume (VAV) system in a historical museum
    Schellen, Henk
    van Aarle, Marcel
    Neuhaus, Edgar
    Pernot, Cor
    RESEARCH ON BUILDING PHYSICS, 2010, : 519 - 526
  • [2] Vav2 is required for cell spreading
    Marignani, PA
    Carpenter, CL
    JOURNAL OF CELL BIOLOGY, 2001, 154 (01): : 177 - 186
  • [3] Regulation of Vav2 exchange protein by EGF
    Buday, L
    Bauer, P
    Tamás, P
    Downward, J
    FASEB JOURNAL, 2001, 15 (05): : A906 - A906
  • [4] Association of VAV2 and VAV3 polymorphisms with cardiovascular risk factors
    Perretta-Tejedor, Nuria
    Fernandez-Mateos, Javier
    Garcia-Ortiz, Luis
    Gomez-Marcos, Manuel A.
    Recio-Rodriguez, Jose I.
    Agudo-Conde, Cristina
    Rodriguez-Sanchez, Emiliano
    Morales, Ana I.
    Lopez-Hernandez, Francisco J.
    Lopez-Novoa, Jose M.
    Gonzalez-Sarmiento, Rogelio
    Martinez-Salgado, Carlos
    SCIENTIFIC REPORTS, 2017, 7
  • [5] Association of VAV2 and VAV3 polymorphisms with cardiovascular risk factors
    Nuria Perretta-Tejedor
    Javier Fernández-Mateos
    Luis García-Ortiz
    Manuel A. Gómez-Marcos
    José I. Recio-Rodríguez
    Cristina Agudo-Conde
    Emiliano Rodriguez-Sánchez
    Ana I. Morales
    Francisco J. López-Hernández
    José M. López-Novoa
    Rogelio González-Sarmiento
    Carlos Martínez-Salgado
    Scientific Reports, 7
  • [6] Optimized supply-air temperature (SAT) in variable-air-volume (VAV) systems
    Ke, YP
    Mumma, SA
    ENERGY, 1997, 22 (06) : 601 - 614
  • [7] PROVIDING CONSTANT VENTILATION IN VARIABLE AIR VOLUME SYSTEMS
    COHEN, T
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1994, 36 (05): : 38 - 40
  • [8] Comparative energy analysis of a constant air volume (CAV) system and a variable air volume (VAV) system for a software laboratory
    Refrigeration and Air Conditioning Division, Department of Mechanical Engineering, Anna University, Chennai, India
    不详
    Int. J. Vent., 2006, 2 (229-237):
  • [9] Controlling minimum ventilation volume in VAV systems
    Kettler, John P.
    ASHRAE Journal, 1998, 40 (05): : 45 - 48
  • [10] Isolation and characterization of murine vav2, a member of the vav family of proto-oncogenes
    Schuebel, KE
    Bustelo, XR
    Nielsen, DA
    Song, BJ
    Barbacid, M
    Goldman, D
    Lee, IJ
    ONCOGENE, 1996, 13 (02) : 363 - 371