Ultra-short heart rate variability recording reliability: The effect of controlled paced breathing

被引:35
|
作者
Melo, Hiago M. [1 ,2 ,3 ]
Martins, Thiago C. [1 ]
Nascimento, Lucas M. [1 ]
Hoeller, Alexandre A. [3 ,4 ]
Walz, Roger [2 ,3 ,4 ]
Takase, Emilio [1 ]
机构
[1] Univ Fed Santa Catarina, Dept Psicol, LEC, Florianopolis, SC, Brazil
[2] Univ Fed Santa Catarina, Programa Posgrad Neurociencias, Florianopolis, SC, Brazil
[3] Univ Fed Santa Catarina, Programa Posgrad Ciencias Med, Florianopolis, SC, Brazil
[4] Univ Fed Santa Catarina, Dept Clin Med, Ctr Neurociencias Aplicadas CeNAp, Florianopolis, SC, Brazil
关键词
autonomic nervous system; cardiac autonomic regulation; controlled paced breathing; heart rate variability; rMSSD; ultra-short-term recording; POINCARE PLOT; INDEXES; OBESITY; STRESS; IMPACT; MODEL; HRV;
D O I
10.1111/anec.12565
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundRecent studies have reported that Heart Rate Variability (HRV) indices remain reliable even during recordings shorter than 5min, suggesting the ultra-short recording method as a valuable tool for autonomic assessment. However, the minimum time-epoch to obtain a reliable record for all HRV domains (time, frequency, and Poincare geometric measures), as well as the effect of respiratory rate on the reliability of these indices remains unknown. MethodsTwenty volunteers had their HRV recorded in a seated position during spontaneous and controlled respiratory rhythms. HRV intervals with 1, 2, and 3min were correlated with the gold standard period (6-min duration) and the mean values of all indices were compared in the two respiratory rhythm conditions. ResultsrMSSD and SD1 were more reliable for recordings with ultra-short duration at all time intervals (r values from 0.764 to 0.950, p<0.05) for spontaneous breathing condition, whereas the other indices require longer recording time to obtain reliable values. The controlled breathing rhythm evokes stronger r values for time domain indices (r values from 0.83 to 0.99, p<0.05 for rMSSD), but impairs the mean values replicability of domains across most time intervals. Although the use of standardized breathing increases the correlations coefficients, all HRV indices showed an increase in mean values (t values from 3.79 to 14.94, p<0.001) except the RR and HF that presented a decrease (t=4.14 and 5.96, p<0.0001). ConclusionOur results indicate that proper ultra-short-term recording method can provide a quick and reliable source of cardiac autonomic nervous system assessment.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Reliability of Ultra-Short ECG Indices for Heart Rate Variability
    Nussinovitch, Udi
    Elishkevitz, Keren Politi
    Katz, Keren
    Nussinovitch, Moshe
    Segev, Shlomo
    Volovitz, Benjamin
    Nussinovitch, Naomi
    [J]. ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2011, 16 (02) : 117 - 122
  • [2] Accuracy of ultra-short heart rate variability measures
    Thong, T
    Li, KH
    McNames, J
    Aboy, M
    Goldstein, B
    [J]. PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 2424 - 2427
  • [3] The Effect of High-Altitude Acclimatisation on Ultra-Short Heart Rate Variability
    Boos, Christopher John
    Mellor, Adrian
    Woods, David Richard
    O'Hara, John Paul
    [J]. FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [4] Evaluating reliability of ultra-short ECG indices of heart rate variability in diabetes mellitus patients
    Nussinovitch, Udi
    Cohen, Ohad
    Kaminer, Keren
    Ilani, Jacob
    Nussinovitch, Naomi
    [J]. JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2012, 26 (05) : 450 - 453
  • [5] Investigation of Lagged Poincare Plot reliability in ultra-short synthetic and experimental Heart Rate Variability series
    Nardelli, M.
    Greco, A.
    Bolea, J.
    Valenza, G.
    Scilingo, E. P.
    Bailon, R.
    [J]. 2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 2329 - 2332
  • [6] Possible Caveats of Ultra-short Heart Rate Variability Reliability: Insights from Recurrence Quantification Analysis
    Melo, Hiago Murilo
    Melo, Mariana Cardoso
    Walz, Roger
    Takase, Emilio
    Faber, Jean
    [J]. XXVII BRAZILIAN CONGRESS ON BIOMEDICAL ENGINEERING, CBEB 2020, 2022, : 2067 - 2075
  • [7] The effects of paced breathing on heart rate variability parameters
    Dimitriev, D.
    Saperova, E.
    Ivanova, A.
    [J]. ACTA PHYSIOLOGICA, 2017, 221 : 116 - 116
  • [8] The effect of paced breathing at the resonance frequency on nonlinear features of heart rate variability
    Ivanova, Alevtina
    Dimitriev, Dmitry
    Saperova, Elena
    [J]. FASEB JOURNAL, 2018, 32 (01):
  • [9] Ultra-short heart rate variability reliability for cardiac autonomic tone assessment in mesial temporal lobe epilepsy
    Melo, Hiago Murilo
    Brum Marques, Jefferson Luiz
    Fialho, Guilherme Loureiro
    Wolf, Peter
    D'Avila, Andre
    Lin, Katia
    Walz, Roger
    [J]. EPILEPSY RESEARCH, 2021, 174
  • [10] ULTRA-SHORT HEART RATE VARIABILITY AS A PREDICTOR OF ARRHYTHMIC EVENTS IN ISCHEMIC CARDIOMYOPATHY
    Rasaratnam, I.
    Krahn, A.
    Leong-Sit, P.
    Gula, L.
    Skanes, A.
    Yee, R.
    Klein, G.
    White, J. A.
    [J]. CANADIAN JOURNAL OF CARDIOLOGY, 2011, 27 (05) : S314 - S315