UK safety-engineered device use: changes since the 2013 sharps regulations

被引:5
|
作者
Grimmond, T. [1 ]
机构
[1] Grimmond & Associates, Microbiol Consultants, Hamilton 3210, New Zealand
来源
OCCUPATIONAL MEDICINE-OXFORD | 2019年 / 69卷 / 05期
关键词
Activation; healthcare; needlestick; occupational; regulations; safety-engineered devices; sharps injury; NEEDLESTICK INJURIES; HEALTH-CARE; PREVENTION; HOSPITALS; IMPACT; RATES;
D O I
10.1093/occmed/kqz087
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background The 2013 UK sharps safety regulations require healthcare facilities to use safety-engineered devices (SEDs) to protect staff. The recent increase in UK-reported occupational exposures could indicate increased reporting or increased exposures from suboptimal SED use. Aims To ascertain SED use through examination of sharps container contents in a sample of UK hospitals. Methods Reusable sharps containers (RSCs) were selected from seven UK hospitals in 2013 and seven different hospitals in 2016. At licensed processing facilities, the operator, wearing protective apparel, decanted RSCs, separated hollow-bore needles (HBNs) from other sharps and enumerated HBNs into capped/uncapped non-SEDs, activated/non-activated/tampered SEDs, and blunt draw-up SEDs. Probability, risk ratios (RRs) and 95% confidence limits (95% CLs) were calculated using WinPepi v2.78. Results In 2013 and 2016, respectively, 2545 HBNs were categorized from 22 RSCs versus 2959 HBNs from 33 RSCs; 70% of HBNs were SEDs versus 93% (P < 0.001; RR 1.33; CL 1.30-1.37); 32% of activatable HBNs were not activated versus 22% (<0.001; 0.67; 0.60-0.76); 41% of HBNs were discarded 'sharp' versus 20% (<0.001; 0.48; 0.44-0.52); 25% of HBNs were uncapped needles versus 6% (<0.001; 0.22; 0.19-0.26); 5% of HBNs were capped needles versus 1% (P > 0.05); and 1% of SEDs were tampered with in both years (P > 0.05). Hospital practices varied widely. Conclusions SED use and activation have increased significantly since 2013. Of concern is that in 2016, 22% of SEDs were non-activated and 20% of sharps were discarded 'sharp'. Increased training in SED handling, assiduous adherence to safe sharps work practices and a higher level of individual safety-ownership are indicated.
引用
收藏
页码:352 / 358
页数:7
相关论文
共 24 条
  • [1] UK safety-engineered device use: changes since the 2013 sharps regulations (vol 69, pg 352, 2019)
    Grimmond, T.
    [J]. OCCUPATIONAL MEDICINE-OXFORD, 2019, 69 (8-9): : 641 - 641
  • [2] USE OF SAFETY-ENGINEERED SCALPELS TO REDUCE SHARPS INJURY IN THE OR: WHAT IS THE EVIDENCE?
    DeGirolamo, K.
    Courtemanche, D.
    Hill, W.
    Kennedy, A.
    Skarsgard, E.
    [J]. JOURNAL OF INVESTIGATIVE MEDICINE, 2012, 60 (01) : 245 - 245
  • [3] SYSTEMATIC REVIEW OF THE VALUE OF SAFETY-ENGINEERED DEVICES IN REDUCING NEEDLESTICK AND SHARPS INJURIES
    Shang, Y.
    Ren, X.
    [J]. VALUE IN HEALTH, 2016, 19 (07) : A704 - A705
  • [4] ECONOMIC ANALYSIS OF THE PREVENTION OF MEDICAL SHARPS INJURIES WITH SAFETY-ENGINEERED DEVICES: A SYSTEMATIC REVIEW
    Barnett, G. S.
    Maclaine, G. D. H.
    [J]. VALUE IN HEALTH, 2013, 16 (07) : A455 - A455
  • [5] Chinks in the armor: Percutaneous injuries from hollow bore safety-engineered sharps devices
    Black, Lisa
    [J]. AMERICAN JOURNAL OF INFECTION CONTROL, 2013, 41 (05) : 427 - 432
  • [6] Safety-Engineered Devices in 2012: The Critical Healthcare Workers in Device Selection
    Jagger, Janine
    Perry, Jane
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2013, 34 (06): : 615 - 618
  • [7] DID SAFETY-ENGINEERED DEVICE IMPLEMENTATION CONTRIBUTETO REDUCING THE RISK OF NEEDLESTICK AND SHARPS INJURIES? RETROSPECTIVE INVESTIGATION OF 20 YEARS OF OBSERVATION IN A SPECIALISTTERTIARY REFERRAL HOSPITAL
    Szczypta, Anna
    Rozanska, Anna
    Siewierska, Malgorzata
    Drozdz, Kamil
    Szura, Miroslaw
    Talaga-Cwiertnia, Katarzyna
    [J]. INTERNATIONAL JOURNAL OF OCCUPATIONAL MEDICINE AND ENVIRONMENTAL HEALTH, 2024, 37 (02) : 234 - 243
  • [8] Safety-engineered device implementation: Does it introduce bias in percutaneous injury reporting?
    Sohn, S
    Eagan, J
    Sepkowitz, KA
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2004, 25 (07): : 543 - 547
  • [9] Investigation of a safety-engineered device to prevent needlestick injury: why has not StatLock stuck?
    Griswold, Sharon
    Bonaroti, Alisha
    Rieder, Christopher J.
    Erbayri, John
    Parsons, Jessica
    Nocera, Romy
    Hamilton, Richard
    [J]. BMJ OPEN, 2013, 3 (04):
  • [10] Impact of a single safety-engineered device on the occurrence of percutaneous injuries in a general hospital in Brazil
    Menezes, Jacqueline A.
    Bandeira, Carolina S.
    Quintana, Marcel
    Stat, Julio C. A. de Lima e Silva
    Calvet, Guilherme A.
    Brasil, Patricia
    [J]. AMERICAN JOURNAL OF INFECTION CONTROL, 2014, 42 (02) : 174 - 177