Combining Optical Coherence Tomography and Fundus Photography to Improve Glaucoma Screening

被引:6
|
作者
Watanabe, Tomoyuki [1 ]
Hiratsuka, Yoshimune [2 ]
Kita, Yoshiyuki [3 ]
Tamura, Hiroshi [4 ,5 ]
Kawasaki, Ryo [6 ]
Yokoyama, Tetsuji [7 ]
Kawashima, Motoko [8 ]
Nakano, Tadashi [1 ]
Yamada, Masakazu [3 ]
机构
[1] Jikei Univ, Dept Ophthalmol, Sch Med, Tokyo 1058461, Japan
[2] Juntendo Univ, Dept Ophthalmol, Sch Med, Tokyo 1138421, Japan
[3] Kyorin Univ, Dept Ophthalmol, Sch Med, Tokyo 1818611, Japan
[4] Kyoto Univ, Dept Ophthalmol & Visual Sci, Grad Sch Med, Kyoto 6068507, Japan
[5] Kyoto Univ, Ctr Innovat Res & Educ Data Sci, Inst Liberal Arts & Sci, Kyoto 6158510, Japan
[6] Osaka Univ Hosp, Artificial Intelligence Ctr Med Res & Applicat, Suita, Osaka 5650871, Japan
[7] Natl Inst Publ Hlth, Dept Hlth Promot, Wako, Saitama 3510197, Japan
[8] Keio Univ, Dept Ophthalmol, Sch Med, Tokyo 1608582, Japan
关键词
diagnostic accuracy; glaucoma; optical coherence tomography; ophthalmologist; screening; NERVE-FIBER LAYER; FREQUENCY-DOUBLING TECHNOLOGY; VISUAL-FIELD LOSS; MACULAR THICKNESS; DIAGNOSTIC-ACCURACY; PARKINSON DISEASE; PREVALENCE; PERFORMANCE; PROGRESSION; PERIMETRY;
D O I
10.3390/diagnostics12051100
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We aimed to evaluate the accuracy of glaucoma screening using fundus photography combined with optical coherence tomography and determine the agreement between ophthalmologists and ophthalmology residents. We used a comprehensive ophthalmologic examination dataset obtained from 503 cases (1006 eyes). Of the 1006 eyes, 132 had a confirmed glaucoma diagnosis. Overall, 24 doctors, comprising two groups (ophthalmologists and ophthalmology residents, 12 individuals/group), analyzed the data presented in three screening strategies as follows: (1) fundus photography alone, (2) fundus photography + optical coherence tomography, and (3) fundus photography + optical coherence tomography + comprehensive examination. We investigated the diagnostic accuracy (sensitivity and specificity). The respective sensitivity and specificity values for the diagnostic accuracy obtained by 24 doctors, 12 ophthalmologists, and 12 ophthalmology residents were as follows: (1) fundus photography: sensitivity, 55.4%, 55.4%, and 55.4%; specificity, 91.8%, 94.0%, and 89.6%; (2) fundus photography + OCT: sensitivity, 80.0%, 82.3%, and 77.8%; specificity, 91.7%, 92.9%, and 90.6%; and (3) fundus photography + OCT + comprehensive examination: sensitivity 78.4%, 79.8%, and 77.1%; specificity, 92.7%, 94.0%, and 91.3%. The diagnostic accuracy of glaucoma screening significantly increased with optical coherence tomography. Following its addition, ophthalmologists could more effectively improve the diagnostic accuracy than ophthalmology residents. Screening accuracy is improved when optical coherence tomography is added to fundus photography.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Value of Combining Optical Coherence Tomography with Fundus Photography in Screening Retinopathy in Patients with High Myopia
    Hao, Yingjuan
    Liu, Shiyang
    Yu, Zhimin
    [J]. JOURNAL OF HEALTHCARE ENGINEERING, 2022, 2022
  • [2] Value of Combining Optical Coherence Tomography with Fundus Photography in Screening Retinopathy in Patients with High Myopia
    Hao, Yingjuan
    Liu, Shiyang
    Yu, Zhimin
    [J]. JOURNAL OF HEALTHCARE ENGINEERING, 2022, 2022
  • [3] Value of Combining Optical Coherence Tomography with Fundus Photography in Screening Retinopathy in Patients with High Myopia
    Hao, Yingjuan
    Liu, Shiyang
    Yu, Zhimin
    [J]. Journal of Healthcare Engineering, 2022, 2022
  • [4] Optical Coherence Tomography vs. Fundus Photography for Diabetic Macular Edema Screening
    Rivera-De La Parra, David
    Jimenez-Corona, Aida
    Perez-Peralta, Liliana
    Guadarrama-Vallejo, Dalia C.
    Aguilar-Salinas, Carlos
    Hernandez-Jimenez, Sergio
    Graue-Hernandez, Enrique
    Almeda-Valdez, Paloma
    [J]. DIABETES, 2015, 64 : A173 - A173
  • [5] Combination of Enhanced Depth Imaging Optical Coherence Tomography and Fundus Images for Glaucoma Screening
    Zailiang Chen
    Xianxian Zheng
    Hailan Shen
    Ziyang Zeng
    Qing Liu
    Zhuo Li
    [J]. Journal of Medical Systems, 2019, 43
  • [6] Combination of Enhanced Depth Imaging Optical Coherence Tomography and Fundus Images for Glaucoma Screening
    Chen, Zailiang
    Zheng, Xianxian
    Shen, Hailan
    Zeng, Ziyang
    Liu, Qing
    Li, Zhuo
    [J]. JOURNAL OF MEDICAL SYSTEMS, 2019, 43 (06)
  • [7] Study of Diagnostic Accuracy: Fundus Photography vs. Optical Coherence Tomography
    Moriche Carretero, Manuel
    Parejo, Ana de los Reyes Sanchez
    Perez, Clara Martinez
    Amores, Remedios Revilla
    Gomez, Angel Perez
    Perez, Marc Biarnes
    [J]. APPLIED SCIENCES-BASEL, 2024, 14 (12):
  • [8] Comparison of optical coherence tomography and fundus photography for measuring the optic disc size
    Neubauer, AS
    Krieglstein, TR
    Chryssafis, C
    Thiel, M
    Kampik, A
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2006, 26 (01) : 13 - 18
  • [9] Assessment of patient specific information in the wild on fundus photography and optical coherence tomography
    Munk, Marion R.
    Kurmann, Thomas
    Marquez-Neila, Pablo
    Zinkernagel, Martin S.
    Wolf, Sebastian
    Sznitman, Raphael
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [10] Diabetic macular edema assessed with optical coherence tomography and stereo fundus photography
    Strom, C
    Sander, B
    Larsen, N
    Larsen, M
    Lund-Andersen, H
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 (01) : 241 - 245