Numerical simulation of fluid-structure interaction in bypassed DeBakey III aortic dissection

被引:16
|
作者
Qiao, Aike [1 ]
Yin, Wencong [1 ]
Chu, Bo [1 ]
机构
[1] Beijing Univ Technol, Coll Life Sci & Bioengn, Ctr Cardiovasc Med Engn, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
biomechanics; cardiovascular disease; cardiovascular implants and devices; haemodynamics; computer aided surgical planning; THORACIC AORTA; SURGICAL APPROACH; B DISSECTION; ROOT MOTION; BLOOD-FLOW; MANAGEMENT; TRANSPORT; ANEURYSMS; REPAIR; RISK;
D O I
10.1080/10255842.2014.881806
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
It was found that bypass graft alone could achieve great effects in treating aortic dissection. In order to investigate the mechanical mechanism and the haemodynamic validity of the bypassing treatment for DeBakey III aortic dissection, patient-specific models of DeBakey III aortic dissection treated with different bypassing strategies were constructed. One of the bypassing strategies is bypassing between ascending aorta and abdominal aorta, and the other is bypassing between left subclavian artery and abdominal aorta. Numerical simulations under physiological flow conditions based on fluid-structure interaction were performed using finite element method. The results show that blood flow velocity, pressure and vessel wall displacement of false lumen are all reduced after bypassing. This phenomenon indicates that bypassing is an effective surgery for the treatment of DeBakey III aortic dissection. The effectiveness to cure through lumen is better when bypassing between left subclavian artery and abdominal aorta, while the effectiveness to cure blind lumen is better when bypassing between ascending aorta and abdominal aorta.
引用
收藏
页码:1173 / 1180
页数:8
相关论文
共 50 条
  • [1] Numerical simulation of fluid-structure interaction by SPH
    Antoci, Carla
    Gallati, Mario
    Sibilla, Stefano
    [J]. COMPUTERS & STRUCTURES, 2007, 85 (11-14) : 879 - 890
  • [2] NUMERICAL SIMULATION OF RADOME WITH FLUID-STRUCTURE INTERACTION
    Kun-Mei, Xu
    Yong, Hu
    Ye, Tang
    [J]. ENGINEERING PLASTICITY AND ITS APPLICATIONS, 2010, : 66 - 70
  • [3] Numerical simulation of two-phase non-Newtonian blood flow with fluid-structure interaction in aortic dissection
    Qiao, Yonghui
    Zeng, Yujie
    Ding, Ying
    Fan, Jianren
    Luo, Kun
    Zhu, Ting
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2019, 22 (06) : 620 - 630
  • [4] Fluid-structure interaction simulation of aortic blood flow
    Crosetto, Paolo
    Reymond, Philippe
    Deparis, Simone
    Kontaxakis, Dimitrios
    Stergiopulos, Nikolaos
    Quarteroni, Alfio
    [J]. COMPUTERS & FLUIDS, 2011, 43 (01) : 46 - 57
  • [5] An approach to the simulation of fluid-structure interaction in the aortic valve
    Carmody, CJ
    Burriesci, G
    Howard, IC
    Patterson, EA
    [J]. JOURNAL OF BIOMECHANICS, 2006, 39 (01) : 158 - 169
  • [6] Fluid-structure interaction simulation of visceral perfusion and impact of different cannulation methods on aortic dissection
    Lee, Gyu-Han
    Heo, Woon
    Lee, Youngjin
    Kim, Tae-Hoon
    Huh, Hyungkyu
    Song, Suk-Won
    Ha, Hojin
    [J]. SCIENTIFIC REPORTS, 2023, 13 (01)
  • [7] Numerical simulation of fluid-structure interaction with SPH method
    Yang, Yu
    Shao, Jiaru
    [J]. JOURNAL OF ENGINEERING-JOE, 2020, 2020 (14): : 958 - 965
  • [8] A numerical simulation of fluid-structure interaction in internal flows
    Stella, F
    Giangi, M
    Paglia, F
    Casata, A
    Simone, D
    Gaudenzi, P
    [J]. NUMERICAL HEAT TRANSFER PART B-FUNDAMENTALS, 2005, 47 (05) : 403 - 418
  • [9] Numerical Simulation of Fluid-Structure Interaction in Undulated Cavity
    Tarek, Nehila
    Elhadj, Benachour
    Mohammed, Hasnat
    Khadidja, Asnoune
    [J]. INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2023, 41 (05) : 1205 - 1216