Arthroscopic suture bridge rotator cuff repair: functional outcome, repair integrity, and preoperative factors related to postoperative outcome

被引:14
|
作者
Rimmke, Nathan [1 ]
Maerz, Tristan [2 ]
Cooper, Ross [2 ]
Yadavalli, Sailaja [3 ]
Anderson, Kyle [1 ]
机构
[1] Beaumont Hlth Syst, Dept Orthopaed Surg, Royal Oak, MI 48073 USA
[2] Beaumont Hlth Syst, Orthopaed Res Labs, 3811 W 13 Mile Rd, Royal Oak, MI 48073 USA
[3] Beaumont Hlth Syst, Dept Diagnost Radiol, Royal Oak, MI 48073 USA
来源
PHYSICIAN AND SPORTSMEDICINE | 2016年 / 44卷 / 02期
关键词
Arthroscopic rotator cuff repair; suture bridge; functional outcomes; retear rate; repair integrity; DOUBLE-ROW; SINGLE-ROW; STRUCTURAL OUTCOMES; TEARS; MANAGEMENT; FIXATION; MINIMUM;
D O I
10.1080/00913847.2016.1168271
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objectives: To assess the retear rate, retear size and location, the clinical impact of a retear, and preoperative patient factors related to postoperative outcome after arthroscopic suture bridge rotator cuff repair.Methods: Fifty six patients with an isolated, full-thickness supraspinatus tendon tear who underwent arthroscopic suture bridge rotator cuff repair were retrospectively identified. Patients were evaluated and rotator cuff integrity was assessed using ultrasonography. Visual analog score (VAS), the American Shoulder and Elbow Surgeon (ASES) score, shoulder range of motion and strength were used for clinical evaluation. Retears were assessed for size and location on ultrasonography.Results: Forty two patients (75%) aged a mean 59.78.6years (range 41-79years) were available for follow-up at a mean 13.5 months. Postoperative evaluation indicated significant improvements in ASES score (49.7618.2 to 86.57 +/- 13.4, P<0.001), VAS pain score (4.69 +/- 2.17 to 0.63 +/- 1.29, P<0.001), forward elevation range of motion (144.1 degrees +/- 29.9 to 159.69 degrees +/- 13.9, P=0.002), and internal rotation ROM (44.13 degrees +/- 12.0 to 52.09 degrees +/- 12.0, P=0.003). The retear rate was 14.28% (6/42). Patients with retears were not older (P=0.526) but had a larger preoperative tear size (3.25cm +/- 0.5 vs 2.05cm +/- 0.48, P<0.001). Preoperative tear size was significantly associated with a postoperative retear (P<0.001). The duration of preoperative symptoms was significantly associated with pain (P=0.029), pain improvement (P=0.013), internal rotation ROM (P=0.002), and internal rotation strength (P=0.004).Conclusions: Arthroscopic suture bridge repair provides good clinical results with a low retear rate. The duration of preoperative symptoms was associated with postoperative outcome, indicating that delaying surgery may result in inferior outcomes.Level of Evidence: IV, Case Series
引用
收藏
页码:126 / 132
页数:7
相关论文
共 50 条
  • [1] The arthroscopic triple-row modified suture bridge technique for rotator cuff repair: functional outcome and repair integrity
    Buckup, Johannes
    Smolen, Daniel
    Hess, Florian
    Sternberg, Christoph
    Leuzinger, Jan
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (02) : 308 - 315
  • [2] Repair Integrity and Functional Outcome After Arthroscopic Rotator Cuff Repair Double-Row Versus Suture-Bridge Technique
    Kim, Kyung Cheon
    Shin, Hyun Dae
    Lee, Woo Yong
    Han, Sun Cheol
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2012, 40 (02): : 294 - 299
  • [3] Functional outcome of arthroscopic rotator cuff repair
    Sallai Imre
    Kovari Eszter
    Koteczki Adam
    Kovacs Balazs
    Magyar Peter
    Futacsi Balazs
    Antal Imre
    Skaliczki Gabor
    [J]. ORVOSI HETILAP, 2014, 155 (16) : 620 - 626
  • [4] Revision Arthroscopic Rotator Cuff Repair: Repair Integrity and Clinical Outcome
    Keener, Jay D.
    Wei, Anthony S.
    Kim, H. Mike
    Paxton, Edward S.
    Teefey, Sharlene A.
    Galatz, Leesa M.
    Yamaguchi, Ken
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (03): : 590 - 598
  • [5] Revision Arthroscopic Rotator Cuff Repair: Repair Integrity and Clinical Outcome
    Kowalsky, Marc S.
    Keener, Jay D.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A : 62 - 74
  • [6] Comparison of Repair Integrity and Functional Outcomes for 3 Arthroscopic Suture Bridge Rotator Cuff Repair Techniques
    Kim, Kyung Cheon
    Shin, Hyun Dae
    Cha, Soo Min
    Lee, Woo Yong
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2013, 41 (02): : 271 - 277
  • [7] Arthroscopic Rotator Cuff Repair Using a Suture Bridge Technique Is the Repair Integrity Actually Maintained?
    Cho, Nam Su
    Lee, Bong Gun
    Rhee, Yong Girl
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2011, 39 (10): : 2108 - 2116
  • [8] Repair integrity and functional outcome after arthroscopic double-row rotator cuff repair - A prospective outcome study
    Sugaya, Hiroyuki
    Maeda, Kazuhiko
    Matsuki, Keisuke
    Moriishi, Joji
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (05): : 953 - 960
  • [9] Repair Tension During Arthroscopic Rotator Cuff Repair is Correlated With Preoperative Tendon Retraction and Postoperative Rotator Cuff Integrity
    Takeda, Yoshitsugu
    Fujii, Koji
    Suzue, Naoto
    Miyatake, Katsutoshi
    Kawasaki, Yoshiteru
    Yokoyama, Kenji
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2021, 37 (09): : 2735 - 2742
  • [10] Preoperative hyaluronic acid injection modulates postoperative functional outcome in patients undergoing arthroscopic rotator cuff repair
    Nakamura, Yosuke
    Gotoh, Masafumi
    Mitsui, Yasuhiro
    Nakamura, Hidehiro
    Ohzono, Hiroki
    Okawa, Takahiro
    Shiba, Naoto
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)