Modeling of the impact of ionic strength on the electroosmotic flow in capillary electrophoresis with uniform and discontinuous buffer systems

被引:81
|
作者
Thormann, W
Zhang, CX
Caslavska, J
Gebauer, P
Mosher, RA
机构
[1] Univ Bern, Dept Clin Pharmacol, CH-3010 Bern, Switzerland
[2] Acad Sci Czech Republ, Inst Analyt Chem, CZ-61142 Brno, Czech Republic
[3] RAM Software Solut, Tucson, AZ 85745 USA
关键词
D O I
10.1021/ac970513x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new dynamic computer model permitting the combined simulation of the temporal behavior of electroosmosis and electrophoresis under constant voltage or current conditions and in a capillary which exhibits a pH-dependent surface charge has been constructed and applied to the description of capillary zone electrophoresis, isotachophoresis, and isoelectric focusing with electroosmotic zone displacement. Electroosmosis is calculated via use of a normalized wall titration curve (mobility vs pH), Two approaches employed for normalization of the experimentally determined wall titration data are discussed, one that considers the electroosmotic mobility to be inversely proportional to the square root of the ionic strength (method based on the Gouy-Chapman theory with the counterion layer thickness being equal to the Debye-Huckel length) and one that assumes the double-layer thickness to be the sum of a compact layer of fixed charges and the Debye-Huckel thickness and the existence of a wall adsorption equilibrium of the buffer cation other than the proton (method described by Salomon, K.; et al. J. Chromatogr, 1991, 559, 69), The first approach is Shown to overestimate the magnitude of electroosmosis, whereas, with the more complex dependence between the electroosmotic mobility and ionic strength, qualitative agreement between experimental and simulation data is obtained, Using one set of electroosmosis input data, the new model is shown to provide detailed insight into the dynamics of electroosmosis in typical discontinuous buffer systems employed in capillary zone electrophoresis (in which the sample matrix provides the discontinuity), in capillary isotachophoresis, and in capillary isoelectric focusing.
引用
收藏
页码:549 / 562
页数:14
相关论文
共 50 条
  • [1] Buffer capacity, ionic strength and heat dissipation in capillary electrophoresis
    Reijenga, JC
    Verheggen, TPEM
    Martens, JHPA
    Everaerts, FM
    JOURNAL OF CHROMATOGRAPHY A, 1996, 744 (1-2) : 147 - 153
  • [2] Characteristics of the electroosmotic flow of electrolyte systems for nonaqueous capillary electrophoresis
    Grob, M
    Steiner, F
    ELECTROPHORESIS, 2002, 23 (12) : 1853 - 1861
  • [3] MANIPULATION OF ELECTROOSMOTIC FLOW IN CAPILLARY ELECTROPHORESIS
    YAO, XW
    WU, D
    REGNIER, FE
    JOURNAL OF CHROMATOGRAPHY, 1993, 636 (01): : 21 - 29
  • [4] RADIAL PH DISTRIBUTION DURING CAPILLARY ELECTROPHORESIS WITH ELECTROOSMOTIC FLOW - ANALYSIS WITH HIGH IONIC-STRENGTH BUFFERS
    VINTHER, A
    SOEBERG, H
    JOURNAL OF CHROMATOGRAPHY, 1992, 589 (1-2): : 315 - 319
  • [5] Electroosmotic flow modulation in capillary electrophoresis by organic cations from ionic liquids
    Mendes, Acacio
    Branco, Luis C.
    Morais, Cristiana
    Simplicio, Ana Luisa
    ELECTROPHORESIS, 2012, 33 (07) : 1182 - 1190
  • [6] CONTROLLING ELECTROOSMOTIC FLOW IN CAPILLARY ZONE ELECTROPHORESIS
    COHEN, N
    GRUSHKA, E
    JOURNAL OF CHROMATOGRAPHY A, 1994, 678 (01) : 167 - 175
  • [7] Measurement of electroosmotic flow in capillary and microchip electrophoresis
    Wang, Wei
    Zhou, Fang
    Zhao, Liang
    Zhang, Jian-Rong
    Zhu, Jun-Jie
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1170 (1-2) : 1 - 8
  • [8] Characterization of electroosmotic flow in argentation capillary electrophoresis
    Fu, CG
    Wang, LX
    Liu, DJ
    CHROMATOGRAPHIA, 2000, 51 (9-10) : 591 - 594
  • [9] Determination of electroosmotic flow in nonaqueous capillary electrophoresis
    Geiser, L
    Mirgaldi, M
    Veuthey, JL
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1068 (01) : 75 - 81
  • [10] Characterization of electroosmotic flow in argentation capillary electrophoresis
    C. G. Fu
    L. X. Wang
    D. J. Liu
    Chromatographia, 2000, 51 : 591 - 594