Impact of Wildfire Smoke Events on Indoor Air Quality and Evaluation of a Low-cost Filtration Method

被引:20
|
作者
Mae, Nathaniel W. [1 ]
Dixon, Clara [1 ]
Jaffe, Daniel A. [1 ,2 ]
机构
[1] Univ Washington Bothell, Bothell, WA 98011 USA
[2] Univ Washington, Seattle, WA 98195 USA
关键词
PM2.5; Indoor air pollution; Filtration; Biomass burning; Laser particle counter; WILDLAND FIRE SMOKE; HEALTH IMPACTS; PARTICLES; POLLUTION; INTERVENTIONS; ULTRAFINE; CLEANER; EXPOSURE; REMOVAL; AEROSOL;
D O I
10.4209/aaqr.210046
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Increased wildland fire activity is producing extreme fine particulate matter (PM2.5) concentrations impacting millions of people every year, especially in the western United States (US). Recommendations for limiting exposure to PM2.5 and associated adverse health outcomes focus on staying inside, closing windows and doors, and increasing filtration; however, relatively little is known about indoor air quality (IAQ) during major smoke events. Indoor and outdoor hourly PM2.5 (mu g m(-3)) measurements from the publicly available PurpleAir sensor (PAS) network were analyzed for 42 sites (26 residential, 6 school, 10 commercial) across the western US during a September 2020 period of heavy wildfire smoke influence. The fraction of ambient PM2.5 that penetrates indoors and remains airborne (F-in), as well as the ratio (I/O) and correlation coefficient (R-2) of indoor to outdoor PM2.5 concentrations, were lower in residential compared to commercial and school buildings. Interventions to improve IAQ were highly influential in PM2.5 infiltration in residential case studies, with multiple, continuously run filter units associated with lower F-in, I/O, and R-2. A low-cost PM2.5 filtration method consisting of a Minimum Efficiency Rating Value-13 (MERV-13) filter attached to a box fan is evaluated as an alternative for improving IAQ during wildland fire smoke events. The MERV-13 fan filter unit proved highly effective at reducing indoor PM2.5 and particles 0.3-1.0 mu m measured by PAS and a particle counter, respectively, when recirculating air in a single room. Low-cost filtration methods can have significant benefit for filtering submicron smoke particles and may reduce exposure to PM2.5 during wildfire smoke events.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Field Evaluation of Low-Cost Particulate Matter Sensors for Measuring Wildfire Smoke
    Holder, Amara L.
    Mebust, Anna K.
    Maghran, Lauren A.
    McGown, Michael R.
    Stewart, Kathleen E.
    Vallano, Dena M.
    Elleman, Robert A.
    Baker, Kirk R.
    [J]. SENSORS, 2020, 20 (17) : 1 - 17
  • [2] Indoor air quality and wildfire smoke impacts in the Pacific Northwest
    Kirk, W. Max
    Fuchs, Madeline
    Huangfu, Yibo
    Lima, Nathan
    O'Keeffe, Patrick
    Lin, Beiyu
    Jobson, Tom
    Pressley, Shelley
    Walden, Von
    Cook, Diane
    Lamb, Brian K.
    [J]. SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2018, 24 (02) : 149 - 159
  • [3] Development of a low-cost air sensor package and indoor air quality monitoring in a California middle school: Detection of a distant wildfire
    Kaduwela, Ajith P.
    Kaduwela, Amal P.
    Jrade, Ely
    Brusseau, Matthew
    Morris, Sean
    Morris, Jennifer
    Risk, Valerie
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2019, 69 (09) : 1015 - 1022
  • [4] Selection and evaluation of commercial low-cost devices for indoor air quality monitoring in schools
    Sá, J.P.
    Chojer, H.
    Branco, P.T.B.S.
    Forstmaier, A.
    Alvim-Ferraz, M.C.M.
    Martins, F.G.
    Sousa, S.I.V.
    [J]. Journal of Building Engineering, 2024, 98
  • [5] Evaluation of a low-cost multi-channel monitor for indoor air quality through a novel, low-cost, and reproducible platform
    Baldelli A.
    [J]. 1600, Elsevier Ltd (17):
  • [6] Evaluation of sensor-based low-cost devices for Indoor Air Quality (IAQ) measurement
    Schuldt, T.
    Schmidt, F.
    [J]. GEFAHRSTOFFE REINHALTUNG DER LUFT, 2019, 79 (1-2): : 7 - 12
  • [7] Wildfire Impact on Indoor and Outdoor PAH Air Quality
    Ghetu, Christine C.
    Rohlman, Diana
    Smith, Brian W.
    Scott, Richard P.
    Adams, Kaley A.
    Hoffman, Peter D.
    Anderson, Kim A.
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2022, 56 (14) : 10042 - 10052
  • [8] Review of low-cost sensors for indoor air quality: Features and applications
    Rodenas Garcia, Milagros
    Spinazze, Andrea
    Branco, Pedro T. B. S.
    Borghi, Francesca
    Villena, Guillermo
    Cattaneo, Andrea
    Di Gilio, Alessia
    Mihucz, Victor G.
    Gomez Alvarez, Elena
    Lopes, Sergio Ivan
    Bergmans, Benjamin
    Orlowski, Cezary
    Karatzas, Kostas
    Marques, Goncalo
    Saffell, John
    Sousa, Sofia I. V.
    [J]. APPLIED SPECTROSCOPY REVIEWS, 2022, 57 (9-10) : 747 - 779
  • [9] School and childcare facility air quality decision-makers' perspectives on using low-cost sensors for wildfire smoke response
    Stampfer, Orly
    Farquhar, Stephanie
    Seto, Edmund
    Karr, Catherine J.
    [J]. BMC PUBLIC HEALTH, 2023, 23 (01)
  • [10] School and childcare facility air quality decision-makers’ perspectives on using low-cost sensors for wildfire smoke response
    Orly Stampfer
    Stephanie Farquhar
    Edmund Seto
    Catherine J. Karr
    [J]. BMC Public Health, 23