The Accuracy Heart Dosimetric Study of Left-breast Cancer Radio-therapy using Deformable Image Registration

被引:4
|
作者
Bai, Xue [1 ,2 ,3 ,4 ]
Wang, Shengye [1 ,5 ,6 ]
Wang, Binbing [1 ,2 ,3 ]
Zhang, Jie [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, Inst Canc & Basic Med ICBM, Beijing, Peoples R China
[2] Univ Chinese Acad Sci, Canc Hosp, Dept Radiat Phys, Beijing, Peoples R China
[3] Zhejiang Canc Hosp, Dept Radiat Phys, Hangzhou 310022, Zhejiang, Peoples R China
[4] Sichuan Univ, Inst Nucl Sci & Technol, Key Lab Radiat Phys & Technol, Chengdu 610064, Sichuan, Peoples R China
[5] Univ Chinese Acad Sci, Canc Hosp, Dept Radiat Oncol, Beijing, Peoples R China
[6] Zhejiang Canc Hosp, Dept Radiat Oncol, Hangzhou 310022, Zhejiang, Peoples R China
关键词
Dose accumulation; Deformable image registration; Breast cancer; Radiation therapy;
D O I
10.1145/3383783.3383803
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The radiation injury of heart is an obviously risk in left-breast cancer radiotherapy. In this study, the uncertainty of intra-fraction and inter-fraction for heart dose was investigated using the 4DCT, CBCT and deformable image registration (DIR) to understand the exact dose. The secondary objective of this study was to evaluate the impact of DIR uncertainty on dose accumulation. 4DCT and CBCT images were scanned for ten left-breast cancer patients before and during 3D-CRT treatment. An anatomically constrained hybrid DIR method and a biomechanical model based DIR method were applied to dose accumulation. Dose scenarios included plan dose (no motion), 4D dose (intra-fraction motion) and accumulated dose (inter-fraction motion). The doses to the heart were assessed. the differences among plan heart dose, 4D heart dose and accumulated dose of the investigated parameters D-mean, D-max, V-10, V-20, V-30 and V-40 were ranged -3.8 similar to 7.1%, -0.6 similar to 0.5%, -1.3 similar to 0.8%, -0.8 similar to 1.7%, -0.8 similar to 1.7% and -0.5 similar to 2.2% respectively. The uncertainty between the two DIR methods were ranged -1.3 similar to 0.2% for all the investigated parameters of heart. There was minimal uncertainty of cardiac dose in DIR algorithms, meanwhile the intra-fraction variation was lager, and the interfraction variation was the largest uncertainty.
引用
收藏
页码:73 / 77
页数:5
相关论文
共 50 条
  • [1] Daily image matching of surgical clips improves breast cancer radio-therapy treatment accuracy
    Owen, G.
    Khanduri, S.
    Pettit, L.
    CLINICAL ONCOLOGY, 2016, 28 : S3 - S4
  • [2] Improving Dose Accuracy in Cancer Radiation Therapy Using Deformable Image Registration
    Amy Liu
    Yadin David
    Fred Hosea
    Richard Wu
    中国医疗设备, 2016, 31 (11) : 9 - 13+22
  • [3] Dosimetric Study of the Deformable Image Registration based Lung Cancer Adaptive Radiotherapy
    Wang, Linjing
    Zhang, Shuxu
    Yuan, Kehong
    Zhou, Lu
    Wang, Ruihao
    2015 8TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI), 2015, : 402 - 406
  • [4] A Dosimetric Study of Volumetric Modulated Arc Radiotherapy for Left-breast Cancer after Breast-conserving Surgery
    Sun, T.
    Yin, Y.
    Lin, X.
    Liu, T.
    Lu, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S842 - S843
  • [5] Accuracy Evaluation of Dose Warping Using Deformable Image Registration in Carbon Ion Therapy
    Miyasaka, Yuya
    Souda, Hikaru
    Chai, Hongbo
    Ishizawa, Miyu
    Sato, Hiraku
    Iwai, Takeo
    INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2025, 15
  • [6] Radiotherapy dose distribution prediction for breast cancer using deformable image registration
    Xue Bai
    Binbing Wang
    Shengye Wang
    Zhangwen Wu
    Chengjun Gou
    Qing Hou
    BioMedical Engineering OnLine, 19
  • [7] Radiotherapy dose distribution prediction for breast cancer using deformable image registration
    Bai, Xue
    Wang, Binbing
    Wang, Shengye
    Wu, Zhangwen
    Gou, Chengjun
    Hou, Qing
    BIOMEDICAL ENGINEERING ONLINE, 2020, 19 (01)
  • [8] Improving Deformable Image Registration Accuracy using a Hybrid Similarity Metric for Adaptive Radiation Therapy
    Shah, Keyur
    Shackleford, James A.
    Kandasamy, Nagarajan
    Sharp, Gregory C.
    MEDICAL IMAGING 2021: IMAGE PROCESSING, 2021, 11596
  • [9] A reference dataset for deformable image registration spatial accuracy evaluation using the COPDgene study archive
    Castillo, Richard
    Castillo, Edward
    Fuentes, David
    Ahmad, Moiz
    Wood, Abbie M.
    Ludwig, Michelle S.
    Guerrero, Thomas
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (09): : 2861 - 2877
  • [10] Is There a Threshold Limit in the Accuracy of Deformable Image Registration (DIR)? A Validation Study Using Deformable Bladder Phantom with Implanted Markers
    Varadhan, R.
    Hui, S.
    Overbeck, C.
    MEDICAL PHYSICS, 2014, 41 (06) : 174 - 175