Glucose biosensor based on multi-walled carbon nanotube modified glassy carbon electrode

被引:59
|
作者
Dai, YQ [1 ]
Shiu, KK [1 ]
机构
[1] Hong Kong Baptist Univ, Dept Chem, Kowloon, Hong Kong, Peoples R China
关键词
multi-walled carbon nanotubes; glassy carbon; glucose oxidase; poly(phenylenediamine); amperometric biosensor;
D O I
10.1002/elan.200303016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric glucose biosensor based on multi-walled carbon nanotube (MWCNT) modified glassy carbon electrode has been developed. MWCNT-modified glassy carbon electrode was obtained by casting the electrode surface with multi-walled carbon nanotube materials. Glucose oxidase was co-immobilized on the MWCNT-modified glassy carbon surface by electrochemical deposition of poly (o-phenylenediamine) film. Enhanced catalytic electro-reduction behavior of oxygen at MWCNT-modified electrode surface was observed at a potential of -0.40 V (vs. Ag \ AgCl) in neutral medium. The steady-state amperometric response to glucose was determined at a selected potential of -0.30 V by means of the reduction of dissolved oxygen consumed by the enzymatic reaction. Common interferents such as ascorbic acid, 4-acetamidophenol, and uric acid did not interfere in the glucose determination. The linear range for glucose determination extended to 2.0 mM and the detection limit was estimated to be about 0.03 mM.
引用
收藏
页码:1697 / 1703
页数:7
相关论文
共 50 条
  • [1] Multi-walled carbon nanotube modified glassy carbon electrode as curcumin sensor
    Mustafa Cittan
    Esra Altuntaş
    Ali Çelik
    [J]. Monatshefte für Chemie - Chemical Monthly, 2020, 151 : 881 - 888
  • [2] Multi-walled carbon nanotube modified glassy carbon electrode as curcumin sensor
    Cittan, Mustafa
    Altuntas, Esra
    Celik, Ali
    [J]. MONATSHEFTE FUR CHEMIE, 2020, 151 (06): : 881 - 888
  • [3] Determination of Eriodictyol by a Modified Multi-Walled Carbon Nanotube Glassy Carbon Electrode
    Cai, Wan-Ling
    Liu, Ling
    Liao, Xue-Qing
    Tao, Kai-Li
    Feng, Fang
    Yang, Gong-Jun
    [J]. ANALYTICAL LETTERS, 2016, 49 (10) : 1502 - 1512
  • [4] Glucose Biosensor Based on a Glassy Carbon Electrode Modified with Multi-Walled Carbon Nanotubes-Chitosan for the Determination of Beef Freshness
    Uwimbabazi, Eric
    Mukasekuru, Marie Rose
    Sun, Xiulan
    [J]. FOOD ANALYTICAL METHODS, 2017, 10 (08) : 2667 - 2676
  • [5] Glucose Biosensor Based on a Glassy Carbon Electrode Modified with Multi-Walled Carbon Nanotubes-Chitosan for the Determination of Beef Freshness
    Eric Uwimbabazi
    Marie Rose Mukasekuru
    Xiulan Sun
    [J]. Food Analytical Methods, 2017, 10 : 2667 - 2676
  • [6] Voltammetric determination of resorcinol on the surface of a glassy carbon electrode modified with multi-walled carbon nanotube
    Ghoreishi, Sayed Mehdi
    Behpour, Mohsem
    Hajisadeghian, Elahe
    Golestaneh, Mahshid
    [J]. ARABIAN JOURNAL OF CHEMISTRY, 2016, 9 : S1563 - S1568
  • [7] Adsorptive detection of ethoxyquin on multi-walled carbon nanotube modified.glassy carbon electrode
    Devi, Kalyana Sundaram Shalini
    Kumar, Annamalai Senthil
    [J]. JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2015, 92 (04) : 435 - 438
  • [8] Electroreduction of oxygen by myoglobin on multi-walled carbon nanotube-modified glassy carbon electrode
    Zhang, L
    Zhao, GC
    Wei, XW
    Yang, ZS
    [J]. CHEMISTRY LETTERS, 2004, 33 (02) : 86 - 87
  • [9] Multi-Walled Carbon Nanotube Modified Glassy Carbon Electrode as a Sensor for the Determination of Raloxifene Hydrochloride
    Kalanur, Shankara S.
    Seetharamappa, J.
    [J]. SENSOR LETTERS, 2011, 9 (04) : 1403 - 1409
  • [10] ELECTROCHEMICAL DETERMINATION OF ACETAMINOPHEN AT THE SURFACE OF A GLASSY CARBON ELECTRODE MODIFIED WITH MULTI-WALLED CARBON NANOTUBE
    Ghoreishi, Sayed Mehdi
    Behpour, Mohsen
    Hajisadeghian, Elahe
    Golestaneh, Mahshid
    [J]. JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2013, 58 (01): : 1513 - 1516