Characterization of the room temperature payload prototype for the cryogenic interferometric gravitational wave detector KAGRA

被引:5
|
作者
Pena Arellano, Fabian Erasmo [1 ]
Sekiguchi, Takanori [2 ]
Fujii, Yoshinori [1 ]
Takahashi, Ryutaro [1 ]
Barton, Mark [1 ]
Hirata, Naoatsu [1 ]
Shoda, Ayaka [1 ]
van Heijningen, Joris [3 ]
Flaminio, Raffaele [1 ]
DeSalvo, Riccardo [4 ,5 ]
Okutumi, Koki [6 ]
Akutsu, Tomotada [1 ]
Aso, Yoichi [1 ]
Ishizaki, Hideharu [1 ]
Ohishi, Naoko [1 ]
Yamamoto, Kazuhiro [2 ]
Uchiyama, Takashi [2 ]
Miyakawa, Osamu [2 ]
Kamiizumi, Masahiro [2 ]
Takamori, Akiteru [7 ]
Majorana, Ettore [8 ]
Agatsuma, Kazuhiro [3 ]
Hennes, Eric [3 ]
van den Brand, Jo [3 ]
Bertolini, Alessandro [3 ]
机构
[1] Natl Astron Observ Japan, 2-21-1 Osawa, Mitaka, Tokyo 1818588, Japan
[2] Inst Cosm Ray Res, 5-1-5 Kashiwanoha, Kashiwa, Chiba 2778582, Japan
[3] Natl Inst Subat Phys, Nikhef Sci Pk 105, NL-1098 XG Amsterdam, Netherlands
[4] Univ Sannio Benevento, Waves Grp, I-82100 Benevento, Italy
[5] Calif State Univ Los Angeles, 5151 State Univ Dr, Los Angeles, CA 90032 USA
[6] Grad Univ Adv Studies, SOKENDAI, Hayama, Kanagawa 2400193, Japan
[7] Univ Tokyo, Earthquake Res Inst, Bunkyo Ku, 1-1-1 Yayoi, Tokyo 1130032, Japan
[8] INFN, Ple Moro 2, I-00185 Rome, Italy
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2016年 / 87卷 / 03期
关键词
D O I
10.1063/1.4942909
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
KAGRA is a cryogenic interferometric gravitational wave detector currently under construction in the Kamioka mine in Japan. Besides the cryogenic test masses, KAGRA will also rely on room temperature optics which will hang at the bottom of vibration isolation chains. The payload of each chain comprises an optic, a system to align it, and an active feedback system to damp the resonant motion of the suspension itself. This article describes the performance of a payload prototype that was assembled and tested in vacuum at the TAMA300 site at the NAOJ in Mitaka, Tokyo. We describe the mechanical components of the payload prototype and their functionality. A description of the active components of the feedback system and their capabilities is also given. The performance of the active system is illustrated by measuring the quality factors of some of the resonances of the suspension. Finally, the alignment capabilities offered by the payload are reported. (C) 2016 AIP Publishing LLC.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Progress on the cryogenic system for the KAGRA cryogenic interferometric gravitational wave telescope
    Sakakibara, Yusuke
    Akutsu, Tomotada
    Chen, Dan
    Khalaidovski, Aleksandr
    Kimura, Nobuhiro
    Koike, Shigeaki
    Kume, Tatsuya
    Kuroda, Kazuaki
    Suzuki, Toshikazu
    Tokoku, Chihiro
    Yamamoto, Kazuhiro
    [J]. CLASSICAL AND QUANTUM GRAVITY, 2014, 31 (22)
  • [2] KAGRA: 2.5 generation interferometric gravitational wave detector
    Akutsu, T.
    Ando, M.
    Arai, K.
    Arai, Y.
    Araki, S.
    Araya, A.
    Aritomi, N.
    Asada, H.
    Aso, Y.
    Atsuta, S.
    Awai, K.
    Bae, S.
    Baiotti, L.
    Barton, M. A.
    Cannon, K.
    Capocasa, E.
    Chen, C-S.
    Chiu, T-W.
    Cho, K.
    Chu, Y-K.
    Craig, K.
    Creus, W.
    Doi, K.
    Eda, K.
    Enomoto, Y.
    Flaminio, R.
    Fujii, Y.
    Fujimoto, M. -K.
    Fukunaga, M.
    Fukushima, M.
    Furuhata, T.
    Haino, S.
    Hasegawa, K.
    Hashino, K.
    Hayama, K.
    Hirobayashi, S.
    Hirose, E.
    Hsieh, B. H.
    Huang, C-Z.
    Ikenoue, B.
    Inoue, Y.
    Ioka, K.
    Itoh, Y.
    Izumi, K.
    Kaji, T.
    Kajita, T.
    Kakizaki, M.
    Kamiizumi, M.
    Kanbara, S.
    Kanda, N.
    [J]. NATURE ASTRONOMY, 2019, 3 (01) : 35 - 40
  • [3] KAGRA: 2.5 generation interferometric gravitational wave detector
    [J]. Nature Astronomy, 2019, 3 : 35 - 40
  • [4] Status of a cryogenic mirror suspension for KAGRA gravitational wave detector
    Ushiba, Takafumi
    [J]. 15TH MARCEL GROSSMANN MEETING, PT A, 2022, : 1606 - 1611
  • [5] Status of the cryogenic payload system for the KAGRA detector
    Kumar, R.
    Chen, D.
    Hagiwara, A.
    Kajita, T.
    Miyamoto, T.
    Suzuki, T.
    Sakakibara, Y.
    Tanaka, H.
    Yamamoto, K.
    Tomaru, T.
    [J]. 11TH EDOARDO AMALDI CONFERENCE ON GRAVITATIONAL WAVES (AMALDI 11), 2016, 716
  • [6] Prospects for improving the sensitivity of the cryogenic gravitational wave detector KAGRA
    Michimura, Yuta
    Komori, Kentaro
    Enomoto, Yutaro
    Nagano, Koji
    Nishizawa, Atsushi
    Hirose, Eiichi
    Leonardi, Matteo
    Capocasa, Eleonora
    Aritomi, Naoki
    Zhao, Yuhang
    Flaminio, Raffaele
    Ushiba, Takafumi
    Yamada, Tomohiro
    Wei, Li-Wei
    Takeda, Hiroki
    Tanioka, Satoshi
    Ando, Masaki
    Yamamoto, Kazuhiro
    Hayama, Kazuhiro
    Haino, Sadakazu
    Somiya, Kentaro
    [J]. PHYSICAL REVIEW D, 2020, 102 (02)
  • [8] Cryogenic contamination speed for cryogenic laser interferometric gravitational wave detector
    Miyoki, S
    Tomaru, T
    Ishitsuka, H
    Ohashi, M
    Kuroda, K
    Tatsumi, D
    Uchiyama, T
    Suzuki, T
    Sato, N
    Haruyama, T
    Yamamoto, A
    Shintomi, T
    [J]. CRYOGENICS, 2001, 41 (5-6) : 415 - 420
  • [9] Sapphire mirror for the KAGRA gravitational wave detector
    Hirose, Eiichi
    Bajuk, Dan
    Billingsley, GariLynn
    Kajita, Takaaki
    Kestner, Bob
    Mio, Norikatsu
    Ohashi, Masatake
    Reichman, Bill
    Yamamoto, Hiroaki
    Zhang, Liyuan
    [J]. PHYSICAL REVIEW D, 2014, 89 (06):
  • [10] Interferometer design of the KAGRA gravitational wave detector
    Aso, Yoichi
    Michimura, Yuta
    Somiya, Kentaro
    Ando, Masaki
    Miyakawa, Osamu
    Sekiguchi, Takanori
    Tatsumi, Daisuke
    Yamamoto, Hiroaki
    [J]. PHYSICAL REVIEW D, 2013, 88 (04):