Prediction of building indoor temperature response in variable air volume systems

被引:11
|
作者
Ghofrani, Ali [1 ]
Nazemi, Seyyed Danial [1 ]
Jafari, Mohsen A. [1 ]
机构
[1] Rutgers State Univ, Dept Ind & Syst Engn, Piscataway, NJ 08854 USA
关键词
HVAC; thermal modelling; indoor temperature; temperature prediction; neural networks; VAV systems; NEURAL-NETWORK; ENERGY; MODELS; SIMULATION; HUMIDITY;
D O I
10.1080/19401493.2019.1688393
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A major challenge to devise smart HVAC control is to ensure that the control system considers the non-linearities in building hygrothermal relationships. In this paper, we propose hybrid data-driven approaches to capture these non-linearities and accurately predict building zone-level average temperature response to cooling in Variable Air Volume (VAV) systems. The proposed methodologies are based on the heat transfer analysis of a zone and done via neural network and multivariate linear regression models. Damper position is introduced as a categorical variable to alleviate the non-linearity in predictive indoor temperature models. The room temperature response to different damper positions from minimum airflow to maximum airflow is elaborated. Also, the impact of asset degradation on the response model is presented. The proposed model can enhance the control and optimization of building space cooling, and, be used to optimize building's participation in demand response and load shifting.
引用
收藏
页码:34 / 47
页数:14
相关论文
共 50 条
  • [1] Exergy analysis of variable air volume systems for an office building
    Wei, Zhentao
    Zmeureanu, Radu
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (02) : 387 - 392
  • [2] Prediction of Indoor Temperature in an Institutional Building
    Afroz, Zakia
    Shafiullah, G. M.
    Urmee, Tania
    Higgins, Gary
    [J]. PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY, 2017, 142 : 1860 - 1866
  • [3] Prediction of Indoor Air Temperature Using Weather Data and Simple Building Descriptors
    Aguilera, Jose Joaquin
    Andersen, Rune Korsholm
    Toftum, Jorn
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (22)
  • [4] A thermal environmental model for indoor air temperature prediction and energy consumption in pig building
    Xie, Qiuju
    Ni, Ji-Qin
    Bao, Jun
    Su, Zhongbin
    [J]. BUILDING AND ENVIRONMENT, 2019, 161
  • [5] Model and program for the prediction of the indoor air temperature and indoor air relative humidity
    Haeupl, P.
    Bishara, A.
    Hansel, F.
    [J]. CONTRIBUTIONS TO BUILDING PHYSICS, 2013, : 619 - 625
  • [6] Model and program for the prediction of the indoor air temperature and indoor air relative humidity
    Bishara, Ayman
    Haeupl, Peter
    Hansel, Frank
    [J]. JOURNAL OF BUILDING PHYSICS, 2014, 38 (02) : 103 - 120
  • [7] CONTROL OF VARIABLE AIR VOLUME SYSTEMS
    JANISSE, NJ
    [J]. ASHRAE JOURNAL, 1969, 11 (06): : 70 - &
  • [8] A COMPARISON STUDY FOR ACTIVE CHILLED BEAM AND VARIABLE AIR VOLUME SYSTEMS FOR AN OFFICE BUILDING
    Yau, Y. H.
    Tam, J. H.
    [J]. CLEANER ENERGY FOR CLEANER CITIES, 2018, 152 : 378 - 383
  • [9] Optimized supply-air temperature (SAT) in variable-air-volume (VAV) systems
    Ke, YP
    Mumma, SA
    [J]. ENERGY, 1997, 22 (06) : 601 - 614
  • [10] INFLUENCE OF THE BUILDING ENERGY EFFICIENCY ON INDOOR AIR TEMPERATURE
    Lazovic, Ivan M.
    Turanjanin, Valentina M.
    Vucicevic, Biljana S.
    Jovanovic, Marina P.
    Jovanovic, Rastko D.
    [J]. THERMAL SCIENCE, 2022, 26 (4B): : 3605 - 3618