Resistance to electrochemical corrosion under conditions of sterilisation of guide wires used in endourological treatment

被引:0
|
作者
Przondziono, Joanna [1 ]
Walke, Witold [2 ]
机构
[1] Silesian Tech Univ, Krasinskiego 8, PL-40019 Katowice, Poland
[2] Silesian Tech Univ, PL-41800 Zabrze, Poland
关键词
endourology; X10CrNi18-8; steel; steam sterilisation; potentiodynamic tests; SURFACE;
D O I
10.4028/www.scientific.net/SSP.212.163
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The influence of surface modification and steam sterilisation process on the corrosion characteristics of wires made of X10CrNi18-8 steel used for production of guide wires in endourological treatment was analysed in the study. Corrosion tests were made in artificial urine solution with application of electrochemical testing system VoltaLab PGP201. Resistance to pitting corrosion was evaluated on the ground of registered anodic polarisation curves by means of potentiodynamic method. The tests comprised wires with surface that was ground, electrochemically polished and chemically passivated. Steam sterilisation was performed in autoclave Basic Plus by Mocom. The tests proved that surface modification improved corrosion characteristics of the wire to a great extent. The best corrosion resistance in artificial urine was observed in wire whose surface was successively ground, polished and chemically passivated. It was also proved that chemical passivation process has a favourable impact on corrosion resistance improvement under sterilisation conditions.
引用
收藏
页码:163 / +
页数:2
相关论文
共 50 条
  • [1] IMPACT OF STERILISATION AND STRAIN HARDENING IN DRAWING PROCESS ON RESISTANCE TO ELECTROCHEMICAL CORROSION OF WIRES INTENDED IN CARDIOLOGY
    Przondziono, J.
    Hadasik, E.
    Walke, W.
    Mendala, J.
    ARCHIVES OF METALLURGY AND MATERIALS, 2016, 61 (01) : 249 - 252
  • [2] Influence of hardening and surface modification of endourological wires on corrosion resistance
    Walke, Witold
    Przondziono, Joanna
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2012, 14 (03) : 93 - 99
  • [3] A COMPARATIVE STUDY OF THE CORROSION OF WIRE USED IN UROLOGICAL TREATMENT UNDER STERILISATION
    Walke, W.
    Przondziono, J.
    METALURGIJA, 2012, 51 (02): : 237 - 240
  • [4] IMPACT OF STRAIN IN DRAWING PROCESS AND SURFACE MODIFICATION ON RESISTANCE TO ELECTROCHEMICAL CORROSION OF WIRES USED IN DENTISTRY
    Przondziono, J.
    Hadasik, E.
    Walke, W.
    Szala, J.
    ARCHIVES OF METALLURGY AND MATERIALS, 2015, 60 (03) : 1865 - 1869
  • [5] Forecasting of Corrosion Properties of Steel Wires for Production of Guide Wires for Cardiological Treatment
    Przondziono, J.
    Walke, W.
    Hadasik, E.
    Mlynarski, R.
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2013, 2013
  • [6] The effect of strain hardening on resistance to electrochemical corrosion of wires for orthopaedics
    Przondziono, J.
    Walke, W.
    Hadasik, E.
    Szymszal, J.
    TECHNOLOGIES AND PROPERTIES OF MODERN UTILISED MATERIALS (TPMUM 2012), 2012, 35
  • [7] Corrosion fatigue and electrochemical behaviour of steel wires used in bridge cables
    Liu, Zhongxiang
    Guo, Tong
    Yu, Xiaming
    Huang, Xuelin
    Correia, Jose
    FATIGUE & FRACTURE OF ENGINEERING MATERIALS & STRUCTURES, 2021, 44 (01) : 63 - 73
  • [8] Corrosion of orthodontic wires according to heat treatment conditions
    Oh, KT
    Hwang, CJ
    Park, YS
    Kim, KN
    MATERIALS TRANSACTIONS, 2002, 43 (12) : 3078 - 3082
  • [9] Enhanced corrosion resistance of hard steel wires produced by electrochemical cold drawing
    Zhao, Dong
    Ye, Feng
    Unigovski, Yaakov B.
    Gutman, Emmanuel M.
    Shneck, Roni
    JOURNAL OF METALS MATERIALS AND MINERALS, 2019, 29 (03): : 10 - 16
  • [10] Corrosion resistance of premodeled wires made of stainless steel used for heart electrotherapy leaders
    Przondziono, J.
    Walke, W.
    Mlynarski, R.
    Szatka, W.
    TECHNOLOGIES AND PROPERTIES OF MODERN UTILISED MATERIALS (TPMUM 2012), 2012, 35