Performance evaluation and thermal analysis of heat pipe flue gas waste heat utilization system

被引:6
|
作者
Wang Yongjia [1 ]
Chen Ying [2 ]
Wang Kai [1 ]
Li Xuefei [1 ]
机构
[1] Huadian Elect Power Res Inst Co Ltd, 3377 Second Ring South Rd, Jinan 250000, Peoples R China
[2] CNOOC Petrochem Engn Co Ltd, 9999 Jingshi Rd, Jinan 250000, Peoples R China
关键词
Waste heat utilization; Energy saving; Heat pipe; Condensate;
D O I
10.1016/j.egyr.2022.03.100
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A heat pipe flue gas waste heat utilization system is installed in front of the inlet of the electrostatic precipitator of a boiler to heat the condensate of the steam turbine. In order to understand the performance characteristics of the system, the performance evaluation of flue gas waste heat utilization and transformation is carried out. When the load is 310 MW similar to 325 MW, the average flue gas temperature drop of the heat pipe heat exchanger is 26.3 degrees C. The average flue gas temperature deviation at the outlet of the heat exchanger on the left and right sides of the boiler is 10.9 degrees C, which reduces the flue gas temperature deviation on both sides by 8.1 degrees C compared with that before transformation. When the average flow of condensation is 202 t/h, the average temperature rise of condensation is 47.4 degrees C. Converted to 330 MW load, the flue gas side resistance of heat exchanger is about 151 Pa. By increasing the condensate temperature, the system can reduce the coal consumption of power supply by 1.3 g/(kW h). (C) 2022 The Author(s). Published by Elsevier Ltd.
引用
收藏
页码:210 / 217
页数:8
相关论文
共 50 条
  • [1] Simulation Analysis of Flue Gas Waste Heat Utilization Retrofit Based on ORC System
    Yan, Liqing
    Liu, Jiang
    Ying, Guangwei
    Zhang, Ning
    [J]. Energy Engineering: Journal of the Association of Energy Engineering, 2023, 120 (08): : 1919 - 1938
  • [2] Thermal performance analysis of heat pipe heat exchanger for effective waste heat recovery
    Geum, Gyohoon
    Kang, Sukkyung
    Cho, Sehyeon
    Kong, Daeyoung
    Lee, Seungjae
    Seo, JinHyeuk
    Shin, Dong Hwan
    Lee, Seong Hyuk
    Lee, Jungho
    Lee, Hyoungsoon
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 151
  • [3] Airside thermal-hydraulic performance evaluation of flue gas coolers for waste heat recovery
    Feng, Zhangwei
    Su, Binjie
    Xin, Chengyun
    Zhou, Tuo
    Hao, Yong
    Fu, Tairan
    [J]. APPLIED THERMAL ENGINEERING, 2023, 228
  • [4] Application of Exergy Analysis in Flue Gas Condensation Waste Heat Recovery System Evaluation
    Zhang, Le
    Zhai, Huixing
    He, Jiayuan
    Yang, Fan
    Wang, Suilin
    [J]. ENERGIES, 2022, 15 (20)
  • [5] PERFORMANCE OF A HEAT-PIPE BASED WASTE-HEAT RECOVERY AND UTILIZATION SYSTEM FOR A GAS-TURBINE ENGINE
    AKYURT, M
    NAJJAR, YSH
    HABEEBULLAH, MB
    [J]. JOURNAL OF THE INSTITUTE OF ENERGY, 1995, 68 (475): : 80 - 84
  • [6] Performance Analysis of an Absorption Heat Pump System for Waste Heat and Moisture Cascade Recovery from Flue Gas
    Li, Zongjin
    Xue, Shaoxin
    Hu, Dongzi
    Teng, Da
    Zhang, Shiping
    Shen, Guoqing
    [J]. ACS OMEGA, 2022, 7 (28): : 24596 - 24605
  • [7] Analysis of heat pump flue gas waste heat recovery and nitrogen reduction system
    Qunli, Zhang
    Yushi, Wang
    Hongbao, Zhai
    Yingjie, Guo
    Qiuyue, Zhang
    Haotian, Huang
    [J]. Huagong Jinzhan/Chemical Industry and Engineering Progress, 2023, 42 (12): : 6600 - 6608
  • [8] Application of Gravity Heat Pipe for Recovering Waste Heat from Boiler Flue Gas
    Ma, H. B.
    Zhang, P.
    Fan, S. L.
    [J]. INTERNATIONAL CONFERENCE ON COMPUTER SCIENCE AND ENVIRONMENTAL ENGINEERING (CSEE 2015), 2015, : 251 - 255
  • [9] Design of Temperature Monitoring System for Gas Fired Boiler Flue Gas Waste Heat Utilization
    Feng, Dongmei
    Dai, Dongbing
    Li, Siteng
    Liu, Zhengguang
    [J]. 2023 35TH CHINESE CONTROL AND DECISION CONFERENCE, CCDC, 2023, : 1988 - 1992
  • [10] Modeling and simulation of combined gas turbine engine and heat pipe system for waste heat recovery and utilization
    Lamfon, NJ
    Najjar, YSH
    Akyurt, M
    [J]. ENERGY CONVERSION AND MANAGEMENT, 1998, 39 (1-2) : 81 - 86