Data-driven approach for automatic detection of aortic valve opening: B point detection from impedance cardiogram

被引:3
|
作者
Sheikh, Shafa-at Ali [1 ,2 ]
Gurel, Nil Z. [3 ,4 ]
Gupta, Shishir [5 ]
Chukwu, Ikenna V. [5 ]
Levantsevych, Oleksiy [5 ]
Alkhalaf, Mhmtjamil [5 ]
Soudan, Majd [5 ]
Abdulbaki, Rami [5 ]
Haffar, Ammer [5 ]
Vaccarino, Viola [5 ]
Inan, Omer T. [2 ]
Shah, Amit J. [5 ,6 ,7 ]
Clifford, Gari D. [1 ,8 ,9 ]
Bahrami Rad, Ali [1 ]
机构
[1] Emory Univ, Dept Biomed Informat, Atlanta, GA 30322 USA
[2] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
[3] Univ Calif Los Angeles, David Geffen Sch Med, Neurocardiol Res Ctr Excellence, Los Angeles, CA 90095 USA
[4] Univ Calif Los Angeles, David Geffen Sch Med, Cardiac Arrhythmia Ctr, Los Angeles, CA 90095 USA
[5] Emory Univ, Rollins Sch Publ Hlth, Dept Epidemiol, Atlanta, GA USA
[6] Emory Univ, Sch Med, Dept Med, Div Cardiol, Atlanta, GA USA
[7] Atlanta Vet Affairs Hlth Care Syst, Atlanta, GA USA
[8] Georgia Inst Technol, Dept Biomed Engn, Atlanta, GA 30332 USA
[9] Emory Univ, Atlanta, GA 30322 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
aortic valve opening; B point detection; impedance cardiogram; machine learning based automated algorithm; pre-ejection period; CARDIOVASCULAR REACTIVITY; PREEJECTION PERIOD; STRESS; WAVE;
D O I
10.1111/psyp.14128
中图分类号
B84 [心理学];
学科分类号
04 ; 0402 ;
摘要
Pre-ejection period (PEP), an indicator of sympathetic nervous system activity, is useful in psychophysiology and cardiovascular studies. Accurate PEP measurement is challenging and relies on robust identification of the timing of aortic valve opening, marked as the B point on impedance cardiogram (ICG) signals. The ICG sensitivity to noise and its waveform's morphological variability makes automated B point detection difficult, requiring inefficient and cumbersome expert visual annotation. In this article, we propose a machine learning-based automated algorithm to detect the aortic valve opening for PEP measurement, which is robust against noise and ICG morphological variations. We analyzed over 60 hr of synchronized ECG and ICG records from 189 subjects. A total of 3657 averaged beats were formed using our recently developed ICG noise removal algorithm. Features such as the averaged ICG waveform, its first and second derivatives, as well as high-level morphological and critical hemodynamic parameters were extracted and fed into the regression algorithms to estimate the B point location. The morphological features were extracted from our proposed "variable" physiologically valid search-window related to diverse B point shapes. A subject-wise nested cross-validation procedure was performed for parameter tuning and model assessment. After examining multiple regression models, Adaboost was selected, which demonstrated superior performance and higher robustness to five state-of-the-art algorithms that were evaluated in terms of low mean absolute error of 3.5 ms, low median absolute error of 0.0 ms, high correlation with experts' estimates (Pearson coefficient = 0.9), and low standard deviation of errors of 9.2 ms. For reproducibility, an open-source toolbox is provided.
引用
收藏
页数:25
相关论文
共 50 条
  • [1] Mathematical detection of aortic valve opening (B point) in impedance cardiography: A comparison of three popular algorithms
    Rodriguez Arbol, Javier
    Perakakis, Pandelis
    Garrido, Alba
    Luis Mata, Jose
    Carmen Fernandez-Santaella, M.
    Vila, Jaime
    [J]. PSYCHOPHYSIOLOGY, 2017, 54 (03) : 350 - 357
  • [2] Automatic meter error detection with a data-driven approach
    Chu, Ruimin
    Chik, Li
    Chan, Jeffrey
    Gutzmann, Kurt
    Li, Xiaodong
    [J]. ENGINEERING APPLICATIONS OF ARTIFICIAL INTELLIGENCE, 2023, 123
  • [3] STABILITY OF CARDIAC IMPEDANCE MEASURES - AORTIC OPENING (B-POINT) DETECTION AND SCORING
    DEBSKI, TT
    ZHANG, YX
    JENNINGS, JR
    KAMARCK, TW
    [J]. BIOLOGICAL PSYCHOLOGY, 1993, 36 (1-2) : 63 - 74
  • [4] Data-driven approach for automatic telephony threat analysis and campaign detection
    Bordjiba, Houssem Eddine
    Karbab, ElMouatez Billah
    Debbabi, Mourad
    [J]. DIGITAL INVESTIGATION, 2018, 24 : S131 - S141
  • [5] A new algorithm for improved detection of aortic valve opening by impedance cardiography
    DeMarzo, AP
    Lang, RM
    [J]. COMPUTERS IN CARDIOLOGY 1996, 1996, : 373 - 376
  • [6] An innovative data-driven probabilistic approach for damage detection in Electromechanical Impedance Technique
    Singh, Shishir K.
    Malinowski, Pawel H.
    [J]. COMPOSITE STRUCTURES, 2022, 295
  • [7] Automatic Detection of Aortic Valve Opening Using Seismocardiography in Healthy Individuals
    Choudhary, Tilendra
    Sharma, L. N.
    Bhuyan, M. K.
    [J]. IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2019, 23 (03) : 1032 - 1040
  • [8] Automatic detection of wakefulness and rest intervals in actigraphic signals: A data-driven approach
    Martin-Martinez, D.
    Casaseca-de-la-Higuera, P.
    Andres-de-Llano, J. M.
    Garmendia-Leiza, J. R.
    Alberola-Lopez, S.
    Alberola-Lopez, C.
    [J]. MEDICAL ENGINEERING & PHYSICS, 2014, 36 (12) : 1585 - 1592
  • [9] Toward a better noninvasive assessment of preejection period: A novel automatic algorithm for B-point detection and correction on thoracic impedance cardiogram
    Forouzanfar, Mohamad
    Baker, Fiona C.
    de Zambotti, Massimiliano
    McCall, Corey
    Giovangrandi, Laurent
    Kovacs, Gregory T. A.
    [J]. PSYCHOPHYSIOLOGY, 2018, 55 (08)
  • [10] Detection of opening and closing of the aortic valve using impedance cardiography and its validation by echocardiography
    Bagal, Uttam R.
    Pandey, Prem C.
    Naidu, S. M. M.
    Hardas, S. P.
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (01):