Imaging features of hepatic angiomyolipomas on real-time contrast-enhanced ultrasound

被引:31
|
作者
Wang, Z. [1 ]
Xu, H-X [1 ]
Xie, X-Y [1 ]
Xie, X-H [1 ]
Kuang, M. [2 ]
Xu, Z-F [1 ]
Liu, G-J [1 ]
Chen, L-D [1 ]
Lin, M-X [1 ]
Lu, M-D [2 ]
机构
[1] Sun Yat Sen Univ, Inst Diagnost & Intervent Ultrasound, Affiliated Hosp 1, Dept Med Ultrason, Guangzhou 510080, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, Inst Diagnost & Intervent Ultrasound, Affiliated Hosp 1, Dept Hepatobiliary Surg, Guangzhou 510080, Guangdong, Peoples R China
来源
BRITISH JOURNAL OF RADIOLOGY | 2010年 / 83卷 / 989期
关键词
FOCAL LIVER-LESIONS; CT FINDINGS; SONOGRAPHY; GUIDELINES;
D O I
10.1259/bjr/81174247
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to evaluate the imaging features of hepatic angiomyolipoma (AML) on contrast-enhanced ultrasound (CEUS). The imaging features of 12 pathologically proven hepatic AML lesions in 10 patients who had undergone baseline ultrasound (BUS) and CEUS examinations were evaluated retrospectively. The enhancement extent, pattern and dynamic change, along with the enhancement process, on CEUS were analysed. The diagnostic results of BUS and CEUS before pathological examination were also recorded. The results showed that 75% (9/12) of the AML lesions exhibited mixed echogenicity on BUS and most showed remarkable hyperechogenicity in combination with a hypoechoic or anechoic portion. Arterial flow signals were detected in 75% (9/12) of the lesions on colour Doppler imaging. On CEUS, 66.7% (n=8) of the 12 lesions exhibited hyperenhancement in the arterial phase, slight hyperenhancement (n=2) or isoenhancement (n=6) in the portal phase, and slight hyperenhancement (n=1) or isoenhancement (n=7) in the late phase. Three (25%) lesions exhibited hyperenhancement in the arterial phase and hypoenhancement in both portal and late phases. One (8.3%) lesion exhibited hypoenhancement throughout the CEUS process. Before pathological examination with BUS, only 3 (25%) lesions were correctly diagnosed as hepatic AML. Conversely, on CEUS, correct diagnoses were made for 66.8% (8/12) of hepatic AMLs. Therefore, arterial hyperenhancement and subsequent sustained enhancement on CEUS were found in the majority of hepatic AMLs. The combination of BUS and CEUS leads to the correct diagnosis in the majority of hepatic AMLs, and is higher than the success rate achieved by BUS alone.
引用
收藏
页码:411 / 418
页数:8
相关论文
共 50 条
  • [1] Real-time contrast-enhanced ultrasonography of resected and immunohistochemically proven hepatic angiomyolipomas
    Li, Rui
    Zhang, Xiaohang
    Hua, Xing
    Cai, Ping
    Zhong, Hua
    Guo, Yanli
    Ding, Shiyi
    Yan, XiaoChu
    [J]. ABDOMINAL IMAGING, 2010, 35 (06): : 676 - 682
  • [2] Real-time contrast-enhanced ultrasonography of resected and immunohistochemically proven hepatic angiomyolipomas
    Rui Li
    Xiaohang Zhang
    Xing Hua
    Ping Cai
    Hua Zhong
    Yanli Guo
    Shiyi Ding
    XiaoChu Yan
    [J]. Abdominal Imaging, 2010, 35 : 676 - 682
  • [3] Real-time contrast-enhanced ultrasound imaging of infected focal liver lesions
    Liu, Guang-Jian
    Lu, Ming-De
    Xie, Xiao-Yan
    Xu, Hui-Xiong
    Xu, Zuo-Feng
    Zheng, Yan-Ling
    Liang, Jin-Yu
    Wang, Wei
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2008, 27 (04) : 657 - 666
  • [4] Diagnostic Features of Real-Time Contrast-Enhanced Ultrasound in Focal Nodular Hyperplasia of the Liver
    Piscaglia, F.
    Venturi, A.
    Mancini, M.
    Giangregorio, F.
    Vidili, G.
    Magnolfi, F.
    Mirarchi, M.
    Fornari, F.
    Bolondi, L.
    [J]. ULTRASCHALL IN DER MEDIZIN, 2010, 31 (03): : 276 - 282
  • [5] Real-time contrast-enhanced ultrasound imaging using pulse inversion spectral deconvolution
    Khairalseed, Mawia
    Hoyt, Kenneth
    [J]. 2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 2291 - 2294
  • [6] Real-time contrast-enhanced ultrasound imaging of focal liver lesions in fatty liver
    Liu, Guang-Jian
    Wang, Wei
    Xie, Xiao-Yan
    Xu, Hui-Xiong
    Xu, Zuo-Feng
    Zheng, Yan-Ling
    Liang, Jin-Yu
    Moriyasu, Fuminori
    Lu, Ming-De
    [J]. CLINICAL IMAGING, 2010, 34 (03) : 211 - 221
  • [7] Quantification of cerebral perfusion with "real-time" contrast-enhanced ultrasound
    Rim, SJ
    Leong-Poi, H
    Lindner, JR
    Couture, D
    Ellegala, D
    Mason, H
    Durieux, M
    Kassel, NF
    Kaul, S
    [J]. CIRCULATION, 2001, 104 (21) : 2582 - 2587
  • [8] Real-time excitation-enhanced ultrasound contrast imaging
    Forsberg, F
    Shi, WT
    Knauer, MK
    Hall, AL
    Vecchio, C
    Bernardi, R
    [J]. ULTRASONIC IMAGING, 2005, 27 (02) : 65 - 74
  • [9] Imaging features of ultrasound and contrast-enhanced ultrasound in primary hepatic carcinosarcoma: three cases report
    Liu, Chun-Rui
    Wei, Shu-Ping
    Wu, Min
    Kong, Wen-Tao
    [J]. MEDICAL ULTRASONOGRAPHY, 2019, 21 (04) : 487 - 490
  • [10] Real-time monitoring of contrast-enhanced ultrasound for radio frequency ablation
    Liu, Jiangwei
    Liu, Yan
    Huang, Jianzhao
    Huang, Lei
    Zhao, Pengwei
    [J]. OPEN MEDICINE, 2017, 12 (01): : 474 - 480