Two-phase scintigraphy with technetium 99m-sestamibi in patients with hyperparathyroidism due to chronic renal failure

被引:15
|
作者
Muros, Maria A.
Soto, Juan Bravo
Ruiz, Jose M. Lopez
Rodriguez-Portillo, Mariano
Navarro, Angel Ramirez
Guardia, Maria Bellon
Peran, Fernando
Llamas-Elvira, Jose M.
机构
[1] Hosp Virgen Nieves, Serv Med Nucl, Dept Nucl Med, Granada 18014, Spain
[2] Hosp Virgen Nieves, Dept Nephrol, Granada, Spain
[3] Hosp Reina Sofia, Dept Clin Pathol, Cordoba, Spain
[4] Hosp Virgen Nieves, Dept Lab Med, Granada, Spain
来源
AMERICAN JOURNAL OF SURGERY | 2007年 / 193卷 / 04期
关键词
parathyroid gland hyperplasia; renal hyperparathyroidism; sestamibi scintigraphy;
D O I
10.1016/j.amjsurg.2006.08.078
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The objective of the current study was to study different functional and anatomic features of the hyperplastic gland and clinical and biochemical characteristics of renal hyperparathyroidism (HPT) patients and their relationship with the scintigraphic detection of parathyroid glands. Methods: A retrospective study was performed of 40 patients with chronic renal failure (CRF) who underwent cervical surgery for HPT. Weight, histology, and localization of hyperplastic glands were recorded. Parathyroid cell proliferation was assessed by percentage of S-phase cells. Double-phase scintigraphy with technetium 99m-sestamibi and serum parathyroid intact hormone (PTHi), creatinine, calcium, and phosphate levels were performed. Results: Detection of hyperplastic parathyroid glands by Tc-99m-sestamibi scintigraphy was associated with the weight and inferior localization of the glands. The functionality of the glands as reflected in serum PTHi and phosphorus levels was associated with the number of glands detected. Conclusion: Double-phase Tc-99m-sestainibi scintigraphy is of limited usefulness in patients with renal HPT. Detection of hyperplastic parathyroid glands in patients with CRF depends on the weight and inferior localization of the glands. Serum PTHi, phosphorus and creatine levels are associated with the number of glands detected by means of Tc-99m-sestamibi scintigraphy. (c) 2007 Excerpta Medica Inc. All rights reserved.
引用
收藏
页码:438 / 442
页数:5
相关论文
共 50 条
  • [1] Evaluation of single isotope technetium 99M-Sestamibi in localization efficiency for hyperparathyroidism
    Martin, D
    Rosen, IB
    Ichise, M
    AMERICAN JOURNAL OF SURGERY, 1996, 172 (06): : 633 - 636
  • [2] Single radionuclide scintigraphy with (99m)technetium-sestamibi and ultrasonography in hyperparathyroidism
    Bonjer, HJ
    Bruining, HA
    Valkema, R
    Lameris, JS
    deHerder, WW
    vanderHarst, E
    Pols, HAP
    EUROPEAN JOURNAL OF SURGERY, 1997, 163 (01) : 27 - 32
  • [3] The Effectiveness of Radioguided Parathyroidectomy in Patients With Negative Technetium Tc 99m-Sestamibi Scans
    Chen, Herbert
    Sippel, Rebecca S.
    Schaefer, Sarah
    ARCHIVES OF SURGERY, 2009, 144 (07) : 643 - 647
  • [4] Role of ultrasonography in the management of patients with primary hyperparathyroidism: Retrospective comparison with technetium-99m sestamibi scintigraphy
    Vitetta G.M.
    Neri P.
    Chiecchio A.
    Carriero A.
    Cirillo S.
    Mussetto A.B.
    Codegone A.
    Journal of Ultrasound, 2014, 17 (1) : 1 - 12
  • [5] Efficacy of preoperative diagnostic imaging localization of technetium 99m sestamibi scintigraphy in hyperparathyroidism
    Caixas, A
    Berna, L
    Hernandez, A
    Tebar, FJ
    Madariaga, P
    Vegazo, O
    Bittini, AL
    Moreno, B
    Faure, E
    Abos, D
    Piera, J
    Rodriguez, JM
    Farrerons, J
    PuigDomingo, M
    SURGERY, 1997, 121 (05) : 535 - 541
  • [6] Predicting the effect of intravenous calcitriol on parathyroid gland activity using double-phase technetium Tc 99m-sestamibi scintigraphy
    Torregrosa, JV
    Fuster, D
    Ybarra, J
    Ortín, J
    Moreno, A
    Valveny, N
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2004, 44 (03) : 476 - 480
  • [7] The Effectiveness of Radioguided Parathyroidectomy in Patients With Negative Technetium Tc 99m-Sestamibi Scans DISCUSSION
    Holt, Shelby
    Dr Chen
    ARCHIVES OF SURGERY, 2009, 144 (07) : 647 - 648
  • [8] Early-phase technetium-99m sestamibi scintigraphy can improve preoperative localization in primary hyperparathyroidism
    Burke, Jocelyn F.
    Naraharisetty, Kalpana
    Schneider, David F.
    Sippel, Rebecca S.
    Chen, Herbert
    AMERICAN JOURNAL OF SURGERY, 2013, 205 (03): : 269 - 273
  • [9] Technetium-99m sestamibi scintigraphy and helical CT together in patients with primary hyperparathyroidism: a prospective clinical study
    Lumachi, F
    Tregnaghi, A
    Zucchetta, P
    Marzola, MC
    Cecchin, D
    Marchesi, P
    Fallo, F
    Bui, F
    BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (914): : 100 - 103
  • [10] Technetium-99m sestamibi scintigraphy in monitoring patients with multiple myeloma
    Pinto, AM
    Califano, C
    Di Gennaro, F
    De Renzo, A
    Catalano, L
    Pace, L
    HAEMATOLOGICA, 2000, 85 (09) : 1000 - 1001