Lanthanum-impregnated zeolite modified carbon paste electrode for determination of Cadmium (II)

被引:15
|
作者
Ismail, A. [1 ,3 ]
Kawde, A. [1 ]
Muraza, O. [2 ,3 ]
Sanhoob, M. A. [2 ,3 ]
Al-Setar, A. R. [1 ,3 ]
机构
[1] King Fahd Univ Petr & Minerals, Dept Chem, Dhahran 31261, Saudi Arabia
[2] King Fahd Univ Petr & Minerals, Dept Chem Engn, Dhahran 31261, Saudi Arabia
[3] King Fahd Univ Petr & Minerals, Ctr Res Excellence Nanotechnol, Dhahran 31261, Saudi Arabia
关键词
Mordenite; Electrochemical characterization; Square wave-anodic stripping voltammetry; Cadmium ion; ANODIC-STRIPPING VOLTAMMETRY; SELECTIVE POTENTIOMETRIC SENSOR; POLY(VINYL CHLORIDE) MATRIX; LARGE MORDENITE CRYSTALS; BISMUTH-FILM ELECTRODES; HEAVY-METALS; PVC MATRIX; ELECTROCHEMICAL-BEHAVIOR; NANOMOLAR CONCENTRATIONS; GRAPHITE ELECTRODE;
D O I
10.1016/j.micromeso.2015.12.023
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
We report the hydrothermal synthesis of mordenite zeolite in the absence of organic structuring directing agent (OSDA). The mordenite (MOR) zeolite with molar composition 6Na(2)O:Al2O3:30-SiO2:780H(2)O was characterized by XRD, SEM, EDX, and NMR. It was further impregnated with lanthanum and was used in the construction of zeolite modified carbon paste electrode by mixing with different amounts of graphite and paraffin oil to form a paste. The paste composite with the ratio 65:5:30 (graphite:zeolite:paraffin) displayed the best electrochemical behavior in the cyclic voltammetry of K4Fe(CN)6 and was hence used for the detection of Cd (II) ions. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:164 / 173
页数:10
相关论文
共 50 条
  • [1] DETERMINATION OF CADMIUM(II) WITH A CARBON PASTE ELECTRODE MODIFIED WITH AN ION-EXCHANGE RESIN
    HERNANDEZ, L
    MELGUIZO, JM
    BLANCO, MH
    HERNANDEZ, P
    [J]. ANALYST, 1989, 114 (03) : 397 - 399
  • [2] Voltammetric determination of cysteine using carbon paste electrode modified with Co(II)-Y zeolite
    Nezamzadeh-Ejhieh, Alireza
    Hashemi, Habibeh-Sadat
    [J]. TALANTA, 2012, 88 : 201 - 208
  • [3] Development of a carbon nanotubes paste electrode modified with crosslinked chitosan for cadmium(II) and mercury(II) determination
    Janegitz, Bruno C.
    Figueiredo-Filho, Luiz Carlos S.
    Marcolino-Junior, Luiz H.
    Souza, Silveria P. N.
    Pereira-Filho, Edenir R.
    Fatibello-Filho, Orlando
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 660 (01) : 209 - 216
  • [4] THE ZEOLITE-MODIFIED CARBON PASTE ELECTRODE
    ELMURR, N
    KERKENI, M
    SELLAMI, A
    BENTAARIT, Y
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 246 (02): : 461 - 465
  • [5] VOLTAMMETRIC DETERMINATION OF CADMIUM ON A CARBON PASTE ELECTRODE MODIFIED WITH A CHELATING RESIN
    AGRAZ, R
    SEVILLA, MT
    PINILLA, JM
    HERNANDEZ, L
    [J]. ELECTROANALYSIS, 1991, 3 (4-5) : 393 - 397
  • [6] Naphthazarin modified carbon paste electrode for determination of copper(II)
    Chaisuksant, Rasamee
    Pattanarat, Lertnapa
    Grudpan, Kate
    [J]. MICROCHIMICA ACTA, 2008, 162 (1-2) : 181 - 188
  • [7] Naphthazarin modified carbon paste electrode for determination of copper(II)
    Rasamee Chaisuksant
    Lertnapa Pattanarat
    Kate Grudpan
    [J]. Microchimica Acta, 2008, 162 : 181 - 188
  • [8] Determination of cadmium(II) using carbon paste electrode modified with a Cd-ion imprinted polymer
    Hamid Ashkenani
    Mohammad Ali Taher
    [J]. Microchimica Acta, 2012, 178 : 53 - 60
  • [9] Simultaneous removal of ammonium and phosphate by alkaline-activated and lanthanum-impregnated zeolite
    He, Yinhai
    Lin, Hai
    Dong, Yingbo
    Liu, Quanli
    Wang, Liang
    [J]. CHEMOSPHERE, 2016, 164 : 387 - 395
  • [10] Determination of cadmium(II) using carbon paste electrode modified with a Cd-ion imprinted polymer
    Ashkenani, Hamid
    Taher, Mohammad Ali
    [J]. MICROCHIMICA ACTA, 2012, 178 (1-2) : 53 - 60