Assessment of carbonate-phosphoric acid analytical technique performed using GasBench II in continuous flow isotope ratio mass spectrometry

被引:79
|
作者
Paul, Debajyoti [1 ]
Skrzypek, Grzegorz [1 ]
机构
[1] Univ Texas, Dept Earth & Environm Sci, San Antonio, TX 78249 USA
关键词
stable isotope; carbonate; GasBench; continuous flow; phosphoric acid;
D O I
10.1016/j.ijms.2006.11.006
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
The commonly used online automated analytical method (in particular Thermo GasBench 11) to determine stable carbon and oxygen isotope ratio composition of calcium carbonate in continuous flow isotope ratio mass spectrometry is evaluated. We have analyzed the isotopic composition of three in-house calcium carbonate standards as unknown samples for assessment of speed, accuracy and precision of isotopic measurements. Isotopic analyses Of CO2 extracted from carbonate-phosphoric acid reaction were performed, where temperature of reaction and the time allowed for the reaction was varied in the range 25.-90 degrees C and 3-101 min (and 12 h), respectively. Our results suggest that for isotopic analyses, carbonate-acid reaction may be conducted at any temperature in the range 50-90 degrees C for an hour; 50-70 degrees C seems to be a more restricted range. The results are reproduced accurately if the raw isotopic values are normalized against international standards also analyzed under the same experimental conditions as that of the samples. For isotopically homogeneous calcium carbonate samples, isotopic analyses may also be performed after 15 min of carbonate-acid reaction at 70 degrees C, which is significantly less time than what is routinely used. Care must be taken to ensure complete dissolution of carbonate sample as incomplete reaction or partial dissolution of isotopically heterogeneous grains would result in respective isotopic variability Of CO2 gas produced during carbonate-acid reaction. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:180 / 186
页数:7
相关论文
共 50 条
  • [1] An online method combining a Gasbench II with continuous flow isotope ratio mass spectrometry to determine the content and isotopic compositions of minor amounts of carbonate in silicate rocks
    Zha, Xiang-Ping
    Zhao, Yan-Yan
    Zheng, Yong-Fei
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (15) : 2217 - 2226
  • [2] An online method to determine chlorine stable isotope composition by continuous flow isotope ratio mass spectrometry (CF-IRMS) coupled with a Gasbench II
    Yun-de Liu
    Ai-guo Zhou
    Yi-qun Gan
    Cun-fu Liu
    Ting-ting Yu
    Xiao-qian Li
    Journal of Central South University, 2013, 20 : 193 - 198
  • [3] An online method to determine chlorine stable isotope composition by continuous flow isotope ratio mass spectrometry (CF-IRMS) coupled with a Gasbench II
    Liu Yun-de
    Zhou Ai-guo
    Gan Yi-qun
    Liu Cun-fu
    Yu Ting-ting
    Li Xiao-qian
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2013, 20 (01) : 193 - 198
  • [4] Continuous flow isotope ratio mass spectrometry of carbon dioxide trapped as strontium carbonate
    Harris, D
    Porter, LK
    Paul, EA
    COMMUNICATIONS IN SOIL SCIENCE AND PLANT ANALYSIS, 1997, 28 (9-10) : 747 - 757
  • [5] Long-term performance of the Gasbench isotope ratio mass spectrometry system for the stable isotope analysis of carbonate microsamples
    Spoetl, Christoph
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (11) : 1683 - 1685
  • [6] An online method to determine chlorine stable isotope composition by continuous flow isotope ratio mass spectrometry (CF-IRMS) coupled with a Gasbench Ⅱ
    刘运德
    周爱国
    甘义群
    刘存富
    余婷婷
    李小倩
    JournalofCentralSouthUniversity, 2013, 20 (01) : 193 - 198
  • [7] Oxygen isotope analysis of silicates using continuous flow isotope ratio mass spectrometry
    Kingston, A. W.
    Weis, D.
    Francois, R.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2008, 72 (12) : A474 - A474
  • [8] An analytical system for stable isotope analysis on carbon monoxide using continuous-flow isotope-ratio mass spectrometry
    Pathirana, S. L.
    van der Veen, C.
    Popa, M. E.
    Roeckmann, T.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2015, 8 (12) : 5315 - 5324
  • [9] Determination of carbon, hydrogen and oxygen isotopic compositions in pore waters using continuous flow isotope ratio mass spectrometer coupled with GasBench II
    Lai, M. -Y.
    Yang, T.
    Jiang, S. -Y.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2006, 70 (18) : A340 - A340