Dynamic Stray Current Evaluations on Cut-and-Cover Sections of DC Metro Systems

被引:63
|
作者
Charalambous, Charalambos A. [1 ,3 ]
Aylott, Pete [2 ,4 ]
机构
[1] Univ Cyprus, Dept Elect & Comp Engn, CY-1687 Nicosia, Cyprus
[2] Intertek, Manchester M1 7DP, Lancs, England
[3] Univ Manchester, Sch Elect & Elect Engn, Elect Energy & Power Syst Grp, Manchester M13 9PL, Lancs, England
[4] CAPCIS Ltd, Manchester, Lancs, England
关键词
Cut-and-cover systems; DC transit systems; dynamic modeling; stray current design and control; TRANSIT SYSTEMS;
D O I
10.1109/TVT.2014.2304522
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The tunneling construction in underground DC Metro Systems is mainly based on the bored tunnel method and the cut-and-cover method. Therefore, the stray current assessments and mitigation actions should be tailored according to which method of tunnel construction is used. This paper presents a topologically accurate model for assessing the dynamic stray current picture in cut-and-cover sections of DC metro systems. The dynamic stray current evaluation can provide an indication to the extent of the corrosion problem in the supporting and third-party infrastructures of the system. In this paper, the dynamic evaluations are based on a combination of various ideal and realistic train operation scenarios.
引用
收藏
页码:3530 / 3538
页数:9
相关论文
共 50 条
  • [1] A Multiple Section Model of Stray Current of DC Metro Systems
    Lin, Sheng
    Wang, Aimin
    Liu, Mingjie
    Lin, Xiaohong
    Zhou, Qi
    Zhao, Liping
    IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (03) : 1582 - 1593
  • [2] Shifting technique for a box culvert structure in a cut-and-cover metro tunnel
    Liu, Z. (liuzhenggen@gmail.com), 1600, China Railway Southwest Research Institute Co. Ltd., No.97 Gunan Street, West Hi-Tech Zone, Chengdu, 611731, China (50):
  • [3] Deformations during cut-and-cover construction of MUNI Metro Turnback project
    Koutsoftas, DC
    Frobenius, P
    Wu, CL
    Meyersohn, D
    Kulesza, R
    JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 2000, 126 (04) : 344 - 359
  • [4] Stray Current Simulation Model of the Long Line of DC Metro Systems
    Wang, Aimin
    Lin, Sheng
    Li, Junyi
    He, Zhengyou
    Gaodianya Jishu/High Voltage Engineering, 2020, 46 (04): : 1379 - 1386
  • [5] Evaluation Model of DC Current Distribution in AC Power Systems Caused by Stray Current of DC Metro Systems
    Wang, Aimin
    Lin, Sheng
    Hu, Ziheng
    Li, Junyi
    Wang, Feng
    Wu, Guoxing
    He, Zhengyou
    IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (01) : 114 - 123
  • [6] Design of cut-and-cover tunnels and stations: current practice
    Williams, R
    Sainsbury, E
    Shanmuganathan, S
    Chalmers, G
    (RE)CLAIMING THE UNDERGROUND SPACE, VOLS 1 AND 2, PROCEEDINGS, 2003, : 337 - 342
  • [7] Slurry shield tunnelling: Cut-and-cover and caisson sections in the centre of Berlin
    Windelschmidt, B
    Tiedemann, J
    EIGHTH INTERNATIONAL CONGRESS INTERNATIONAL ASSOCIATION FOR ENGINEERING GEOLOGY AND THE ENVIRONMENT, PROCEEDINGS, VOLS 1-5, 1998, : 3709 - 3714
  • [8] A Uniform Model for Stray Current of Long-Line DC Metro Systems
    Zhou, Qi
    Lin, Sheng
    Lin, Xiaohong
    Wang, Aimin
    IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2022, 8 (02) : 2915 - 2927
  • [9] Investigation of the long-term settlement of a cut-and-cover metro tunnel in a soft deposit
    Di, Honggui
    Zhou, Shunhua
    Xiao, Junhua
    Gong, Quanmei
    Luo, Zhe
    ENGINEERING GEOLOGY, 2016, 204 : 33 - 40
  • [10] A Holistic Stray Current Assessment of Bored Tunnel Sections of DC Transit Systems
    Charalambous, Charalambos A.
    Cotton, Ian
    Aylott, Pete
    Kokkinos, Nikolaos D.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (02) : 1048 - 1056