Towards the clinical implementation of intensity-modulated proton therapy for thoracic indications with moderate motion: Robust optimised plan evaluation by means of patient and machine specific information

被引:25
|
作者
Ribeiro, Cassia O. [1 ]
Visser, Sabine [1 ]
Korevaar, Erik W. [1 ]
Sijtsema, Nanna M. [1 ]
Anakotta, R. Melissa [1 ]
Dieters, Margriet [1 ]
Both, Stefan [1 ]
Langendijk, Johannes A. [1 ]
Wijsman, Robin [1 ]
Muijs, Christina T. [1 ]
Meijers, Arturs [1 ]
Knopf, Antje [1 ,2 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Radiat Oncol, Groningen, Netherlands
[2] Carl von Ossietzky Univ Oldenburg, Div Med Radiat Phys, Oldenburg, Germany
关键词
Intensity-modulated proton therapy; Lung cancer; Oesophageal cancer; 3D robust optimisation; 4D robust optimisation; 4D robustness evaluation; LUNG-CANCER; TREATMENT UNCERTAINTIES; MEDIASTINAL LYMPHOMA; ESOPHAGEAL TUMORS; RADIATION-THERAPY; INTER-FRACTION; BEAM; 4D; RADIOTHERAPY; STAGE;
D O I
10.1016/j.radonc.2021.01.014
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Compared to volumetric modulated arc therapy (VMAT), clinical benefits are anticipated when treating thoracic tumours with intensity-modulated proton therapy (IMPT). However, the current concern of plan robustness as a result of motion hampers its wide clinical implementation. To define an optimal protocol to treat lung and oesophageal cancers, we present a comprehensive evaluation of IMPT planning strategies, based on patient 4DCTs and machine log files. Materials and methods: For ten lung and ten oesophageal cancer patients, a planning 4DCT and weekly repeated 4DCTs were collected. For these twenty patients, the CTV volume and motion were assessed based on the 4DCTs. In addition to clinical VMAT plans, layered rescanned 3D and 4D robust optimised IMPT plans (IMPT_3D and IMPT_4D respectively) were generated, and approved clinically, for all patients. The IMPT plans were then delivered in dry runs at our proton facility to obtain log files, and subsequently evaluated through our 4D robustness evaluation method (4DREM). With this method, for each evaluated plan, fourteen 4D accumulated scenario doses were obtained, representing 14 possible fractionated treatment courses. Results: From VMAT to IMPT_3D, nominal D-mean(lungs-GTV) decreased 2.75 +/- 0.56 Gy(RBE) and 3.76 +/- 0.92 Gy(RBE) over all lung and oesophageal cancer patients, respectively. A more pronounced reduction was verified for D-mean(heart): 5.38 +/- 7.36 Gy(RBE) (lung cases) and 9.51 +/- 2.25 Gy(RBE) (oesophagus cases). Target coverage robustness of IMPT_3D was sufficient for 18/20 patients. Averaged dose in critical structures over all 4DREM scenarios changed only slightly for both IMPT_3D and IMPT_4D. Relative to IMPT_3D, no gain in IMPT_4D was observed. Conclusion: The dosimetric superiority of IMPT over VMAT has been established. For most thoracic tumours, our IMPT_3D planning protocol showed to be robust and clinically suitable. Nevertheless, accurate patient positioning and adapting to anatomical variations over the course of treatment remain compulsory. (C) 2021 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:210 / 218
页数:9
相关论文
共 5 条
  • [1] Patient-specific quality assurance and plan dose errors on breast intensity-modulated proton therapy
    Liu, Chunbo
    Zheng, Dandan
    Bradley, Julie A.
    Vega, Raymond B. Mailhot
    Li, Zuofeng
    Mendenhall, Nancy P.
    Liang, Xiaoying
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 77 : 84 - 91
  • [2] Towards the Clinical Implementation of Pencil Beam Scanned Proton Therapy (PBS-PT) for Thoracic Indications: A Comprehensive 4D Robustness Evaluation Based on Patient and Machine Specific Information
    Ribeiro, C. O.
    Visser, S.
    Meijers, A.
    Korevaar, E. W.
    Wijsman, R.
    Muijs, C.
    Both, S.
    Langendijk, J. A.
    Knopf, A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E754 - E755
  • [3] Systematic Evaluations of a Flat-Panel Imager for Intensity-Modulated Proton Therapy (IMPT) Plan Patient-Specific QA
    Su, Z.
    Rossomme, S.
    Hsi, W.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E855 - E856
  • [4] Evaluation of dosimetric advantages of using patient-specific aperture system with intensity-modulated proton therapy for the shallow depth tumor
    Yasui, Keisuke
    Toshito, Toshiyuki
    Omachi, Chihiro
    Hayashi, Kensuke
    Tanaka, Kenichiro
    Asai, Kumiko
    Shimomura, Akira
    Muramatsu, Rie
    Hayashi, Naoki
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (01): : 132 - 137
  • [5] Patient-specific bolus for range shifter air gap reduction in intensity-modulated proton therapy of head-and-neck cancer studied with Monte Carlo based plan optimization
    Michiels, Steven
    Barragan, Ana Maria
    Souris, Kevin
    Poels, Kenneth
    Crijns, Wouter
    Lee, John A.
    Sterpin, Edmond
    Nuyts, Sandra
    Haustermans, Karin
    Depuydt, Tom
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 128 (01) : 161 - 166