Determination of neotame in beverages, cakes and preserved fruits by column-switching high-performance liquid chromatography

被引:17
|
作者
Yang, Dajing [1 ,2 ]
Chen, Bo [1 ]
机构
[1] Hunan Normal Univ, Minist Educ, Key Lab Chem Biol & Tradit Chinese Med Res, Changsha 410081, Hunan, Peoples R China
[2] Chinese Ctr Dis Control & Prevent, Natl Inst Nutr & Food Safety, Beijing 100021, Peoples R China
关键词
chromatographic analysis; sweeteners; beverages; dried fruit; snack products; LIGHT-SCATTERING DETECTION; 9 INTENSE SWEETENERS; FOODSTUFFS;
D O I
10.1080/19440049.2010.487875
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A column-switching HPLC method for the determination of neotame in beverages, cakes and preserved fruits was developed. After pre-treatment using a Waters Oasis HLB cartridge, the sample solution was separated on two C18 columns using a column-switching technique with a six-port valve. UV detection was performed at 210 nm. The effects of eluent composition and eluate volume on the retention and elution of neotame on SPE cartridge were investigated. The method is simple, rapid, sensitive and has good reproducibility. RSD was lower than 5% (n = 5). The calibration curve of neotame was in the range 5-100 mu g/ml with good linearity (r2 = 0.999). Because neotame was concentrated 10 times from an original sample to a sample solution by solid-phase extraction (SPE), the limit of quantification (LOQ) of the method was 0.5 mg/kg. The recovery yields of neotame spiked in foods was 92% with a coefficient of variation 3.2%. The proposed column-switching HPLC method can be successfully used to determine neotame in routine inspection work.
引用
收藏
页码:1221 / 1225
页数:5
相关论文
共 50 条
  • [1] Direct Determination of Benzamides in Serum by Column-Switching High-Performance Liquid Chromatography
    Ryoko Chiba
    Ayako Ogasawara
    Teppei Kubo
    Hiroyuki Yamazaki
    Masuo Umino
    Yoichi Ishizuka
    Analytical Sciences, 2003, 19 : 785 - 789
  • [3] Direct determination of benzamides in serum by column-switching high-performance liquid chromatography
    Chiba, R
    Ogasawara, A
    Kubo, T
    Yamazaki, H
    Umino, M
    Ishizuka, Y
    ANALYTICAL SCIENCES, 2003, 19 (05) : 785 - 789
  • [4] DETERMINATION OF OXYTETRACYCLINE IN FISH PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND COLUMN-SWITCHING
    EIVINDVIK, K
    RASMUSSEN, KE
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1989, 12 (15): : 3061 - 3071
  • [5] DETERMINATION OF BROMPERIDOL IN SERUM BY AUTOMATED COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HIKIDA, K
    INOUE, Y
    MIYAZAKI, T
    KOJIMA, N
    OHKURA, Y
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 495 : 227 - 234
  • [6] Automated determination of reboxetine by high-performance liquid chromatography with column-switching and ultraviolet detection
    Härtter, S
    Weigmann, H
    Hiemke, C
    JOURNAL OF CHROMATOGRAPHY B, 2000, 740 (01): : 135 - 140
  • [7] DETERMINATION OF RETINOIDS IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND AUTOMATED COLUMN-SWITCHING
    WYSS, R
    METHODS IN ENZYMOLOGY, 1990, 189 : 146 - 155
  • [8] DETERMINATION OF OXIRACETAM IN PLASMA AND URINE BY COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    LECAILLON, JB
    SOUPPART, C
    LEDUIGOU, F
    DUBOIS, JP
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 497 : 223 - 230
  • [9] DETERMINATION OF CEFODIZIME IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH COLUMN-SWITCHING
    BOMPADRE, S
    FERRANTE, L
    LEONE, L
    DEMARTINIS, M
    GINALDI, L
    QUAGLINO, D
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1995, 18 (14): : 2895 - 2909
  • [10] Simple determination of azasetron in rat plasma by column-switching high-performance liquid chromatography
    Um, So Young
    Chae, Song Wha
    Park, Hyun Joo
    Chung, Myeon Woo
    Choi, Sun Ok
    Lee, Hwa Jeong
    JOURNAL OF SEPARATION SCIENCE, 2010, 33 (23-24) : 3638 - 3643