Fatigue behaviour of a PET-Geogrid under cyclic loading

被引:9
|
作者
Zanzinger, Helmut [1 ]
Hangen, Hartmut [2 ]
Alexiew, Dimiter [2 ]
机构
[1] SKZ TeConA GmbH, D-97076 Wurzburg, Germany
[2] HUESKER Synthet GmbH, D-48712 Gescher, Germany
关键词
Geogrid; Cyclic loading; Stress-cycle-diagram; Damage-line;
D O I
10.1016/j.geotexmem.2009.09.011
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
The lines of 'damage-begin' and 'specimen-break' for dynamic loading of a geogrid were determined in a series of laboratory testing. The cyclic load ratio was set to R = 0.5, loading frequency f = 10 Hz and f = 3 Hz. The test results show clearly that the chosen procedure for the determination and analysis of the beginning of damage and break is reproducible and allow for safe extrapolation for lower load levels. Furthermore the method chosen enables explicit decrease of the required testing time. The assumption of linear damage accumulation was examined in two-step-trials. The number of load cycles to 'break' evaluated in 'one-step-tests' compared with those of 'two-step-loading' are practically the same. The existence of 'damage-lines' for the examined geogrid under a dynamic pulsating load of 10 Hz and 3 Hz and a R-value of 0.5 could be verified. Damage of the specimens occurs only for load-cycles lying between the 'damage-line' and the 'stress-cycle-diagram' ('Woehler-curve'). When it comes to dimensioning against 'damage-beginning' or 'break', higher loading frequencies present the critical case. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:251 / 261
页数:11
相关论文
共 50 条
  • [1] Behaviour of Geogrid-Encased Group of Stone Columns Under Monotonic and Cyclic Loading
    Shahu, J. T.
    Kumar, Suresh
    Bhowmik, Riya
    [J]. INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2024, 22 (08) : 1387 - 1406
  • [2] Behaviour of Soft Clayey Soil Improved by Fly Ash and Geogrid under Cyclic Loading
    Karim, Hussein H.
    Samueel, Zeena W.
    Jassem, Adel H.
    [J]. CIVIL ENGINEERING JOURNAL-TEHRAN, 2020, 6 (02): : 225 - 237
  • [3] Behaviour evaluation of a gravelly soil-geogrid interface under normal cyclic loading
    Liu, F. Y.
    Zhu, C.
    Yuan, G. H.
    Wang, J.
    Gao, Z. Y.
    Ni, J. F.
    [J]. GEOSYNTHETICS INTERNATIONAL, 2021, 28 (05) : 508 - 520
  • [4] Tensile behaviour of an HDPE geogrid under cyclic loading: experimental results and empirical modelling
    Cardile, G.
    Moraci, N.
    Pisano, M.
    [J]. GEOSYNTHETICS INTERNATIONAL, 2017, 24 (01) : 95 - 112
  • [5] Shear resistance behaviour of geogrid-confined RC elements under static and cyclic loading
    Chidambaram, R. Siva
    Agarwal, Pankaj
    [J]. CURRENT SCIENCE, 2019, 117 (02): : 260 - 271
  • [6] Numerical behaviour of buried flexible pipes in geogrid-reinforced soil under cyclic loading
    Elshesheny, Ahmed
    Mohamed, Mostafa
    Nagy, Nabil M.
    Sheehan, Therese
    [J]. COMPUTERS AND GEOTECHNICS, 2020, 122
  • [7] Behaviour of geogrid-reinforced aggregate layer overlaying poorly graded sand under cyclic loading
    Soe, A. A.
    Kuwano, J.
    Akram, I
    Kogure, T.
    Kanai, H.
    [J]. PHYSICAL MODELLING IN GEOTECHNICS, VOL 2, 2018, : 1253 - 1258
  • [8] Influence of concrete compressive strength on fatigue behaviour under cyclic compressive loading
    Markert, M.
    Deutscher, M.
    [J]. CURRENT PERSPECTIVES AND NEW DIRECTIONS IN MECHANICS, MODELLING AND DESIGN OF STRUCTURAL SYSTEMS, 2022, : 1339 - 1344
  • [9] Fatigue behaviour of piezoelectric ceramic stack under large cyclic dynamic loading
    Ding, Guangya
    Xing, Zijun
    Chen, Naiyu
    Wang, Jun
    Shi, Li
    [J]. JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2023, 34 (15) : 1809 - 1824
  • [10] Fatigue Fracture Behaviour of Asymmetric Spur Gear Tooth Under Cyclic Loading
    Demet, Seyit Mehmet
    Ersoyoglu, Ali Serhat
    [J]. ECF22 - LOADING AND ENVIRONMENTAL EFFECTS ON STRUCTURAL INTEGRITY, 2018, 13 : 2030 - 2035