Analysis of alternative parameters of dynamic resistance measurement in high voltage circuit breakers

被引:11
|
作者
dos Santos Sousa, Herbet Filipe [1 ]
de Oliveira, Adriano Costa [1 ]
Rocha Xavier, George Victor [1 ]
de Santana, Henrique Nunes [1 ]
da Costa, Edson Guedes [1 ]
Ferreira, Tarso Vilela [2 ]
机构
[1] Univ Fed Campina Grande, Campina Grande, Brazil
[2] Univ Fed Sergipe, Aracaju, Brazil
来源
HIGH VOLTAGE | 2019年 / 4卷 / 03期
关键词
wear; electric resistance measurement; electrical contacts; circuit breakers; dynamic resistance measurement; high-voltage circuit breaker contacts; inevitable degradation processes; electric arcs; current interruption capacity; operational faults; efficient evaluating techniques; degradation level; HVCB contacts; static resistance measurement; main contacts; arcing contacts; mean resistance; DRM curve; AC degradation; nonstandardised technique; specified parameters; DRM technique; continuous evaluation; HVCB ACs; real wear conditions; CONTACT RESISTANCE;
D O I
10.1049/hve.2019.0046
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Throughout its lifetime, high-voltage circuit breaker (HVCB) contacts suffer from inevitable degradation processes, especially during the formation of electric arcs. Highly degraded contacts can reduce the current interruption capacity and increase the chances of operational faults, which might lead to considerable financial losses. Therefore, the use of efficient evaluating techniques is a key factor to achieve systems reliability. The dynamic resistance measurement (DRM) is a technique that can be used to evaluate the degradation level of HVCB' contacts. It stands out from the usual technique, static resistance measurement, by allowing the assessment of both the main contacts and the arcing contacts (ACs). Usually, the mean resistance or the area under the DRM curve is used to estimate the AC degradation. However, DRM is a non-standardised technique and there are no specified parameters to evaluate the real wear conditions. Therefore, an analysis of alternative parameters extractible from the DRM technique is presented in this study, such as amplitude and variance of the DRM curve. The results attest the possible use of more than one parameter for the continuous evaluation of HVCB ACs, characterising the DRM as a more complete and precise diagnosis tool.
引用
收藏
页码:197 / 202
页数:6
相关论文
共 50 条
  • [1] Analysis of Alternative Parameters of Dynamic Resistance Measurement in High Voltage Circuit Breakers
    Sousa, H. F. S.
    de Oliveira, A. C.
    de Santana, H. N.
    da Costa, E. G.
    Ferreira, T. V.
    [J]. 2018 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2018,
  • [2] Parameters for Condition Assessment of the High Voltage Circuit Breakers Arcing Contacts using Dynamic Resistance Measurement
    Obarcanin, Kerim
    Ostojic, Radenko
    Dzuzdanovic, Samir
    [J]. 2017 40TH INTERNATIONAL CONVENTION ON INFORMATION AND COMMUNICATION TECHNOLOGY, ELECTRONICS AND MICROELECTRONICS (MIPRO), 2017, : 1044 - 1048
  • [3] Design and Development of the Software Solution for Analysis and Acquisition of the High Voltage Circuit Breakers Dynamic Resistance Measurement results
    Obarcanin, Kerim
    Secic, Adnan
    Hadzimejlic, Nijaz
    [J]. 2015 8TH INTERNATIONAL CONVENTION ON INFORMATION AND COMMUNICATION TECHNOLOGY, ELECTRONICS AND MICROELECTRONICS (MIPRO), 2015, : 1032 - 1036
  • [4] Method to improve the repeatability of dynamic contact resistance measurement test results for high-voltage circuit breakers
    Cheng, Tingting
    Gao, Wensheng
    Zhao, Dongbo
    Huang, Yulong
    Liu, Weidong
    Zhao, Yuming
    [J]. IET SCIENCE MEASUREMENT & TECHNOLOGY, 2019, 13 (04) : 544 - 552
  • [5] An Overview of Dynamic Contact Resistance Measurement of HV Circuit Breakers
    Bhole A.A.
    Gandhare W.Z.
    [J]. Journal of The Institution of Engineers (India): Series B, 2016, 97 (2) : 219 - 226
  • [6] An Overview of Dynamic Contact Resistance Measurement of HV Circuit Breakers
    Kulkarni, Sanjay
    Doiphode, Balasaheb
    Kulkarni, Yash
    [J]. 2018 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION (T&D), 2018,
  • [7] Evaluation method of contact erosion for high voltage SF6 circuit breakers using dynamic contact resistance measurement
    Cheng, Tingting
    Gao, Wensheng
    Liu, Weidong
    Li, Ruipeng
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2018, 163 : 725 - 732
  • [8] A new measurement method of the dynamic contact resistance of HV circuit breakers
    Landry, M.
    Mercier, A.
    Ouellet, G.
    Rajotte, C.
    Caron, J.
    Roy, M.
    Brikci, Fouad
    [J]. 2006 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION: LATIN AMERICA, VOLS 1-3, 2006, : 1435 - 1442
  • [9] A new measurement method of the dynamic contact resistance of HV circuit breakers
    Landry, M.
    Mercier, A.
    Ouellet, G.
    Rajotte, C.
    Caron, J.
    Roy, M.
    Brikci, Fouad
    [J]. 2005/2006 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, 2006, : 1002 - 1009
  • [10] MEASUREMENT SYSTEM FOR LOW VOLTAGE CIRCUIT BREAKERS
    Kacor, Petr
    [J]. PROCEEDINGS OF THE 8TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2007, 2007, : 534 - 539