Repeatability of retinal nerve fiber layer and ganglion cell complex measurements with spectral-domain optical coherence tomography in normal and glaucomatous eyes

被引:0
|
作者
Abd Elfatah, Hatem F. [1 ]
Ziko, Othman A. [1 ]
Elghropy, Osama M. [1 ]
Ashour, Doaa M. [1 ]
机构
[1] Ain Shams Univ, Dept Ophthalmol, Cairo, Egypt
关键词
cup-to-disk ratio; ganglion cell complex; glaucoma; optical coherence tomography; repeatability; retinal nerve fiber layer; CIRRUS HD-OCT; THICKNESS MEASUREMENTS; REPRODUCIBILITY; TESTS;
D O I
10.4103/ejos.ejos_2_22
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose The current study was set out to investigate the repeatability of retinal nerve fiber layer (RNFL) and ganglion cell complex (GCC) measurements in normal and glaucomatous patients using spectral-domain optical coherence tomography (OCT). Patients and methods This prospective cross-sectional study included 30 healthy and 30 glaucomatous eyes. Three OCT scans with the Nidek RS-3000 advance were performed three times for each scan protocol: optic disk map, optic disk circle, and macular map to determine the RNFL, cup-to-disk ratio, and GCC. Repeatability was assessed by calculating the intraclass correlation coefficient (ICC) and within-subject coefficient of variation. Results The ICC values for RNFL thickness measurements taken from the optic disk map were 0.44-0.86 in normal eyes and 0.33-0.93 in glaucomatous eyes, whereas those obtained from the optic disk circle were 0.76-0.96 and 0.92-0.99 in normal and glaucomatous eyes, respectively. The ICC values for the vertical and horizontal cup-to-disk ratio were 0.81 and 0.86 in normal eyes and 0.83 and 0.90 in glaucomatous eyes, respectively. The ICC values for the upper and lower hemifields were 0.79 and 0.83 in normal eyes and 0.84 and 0.96 in glaucomatous eyes, respectively. Conclusion RNFL thickness measurements obtained using Nidek RS-3000 advance spectral-domain-OCT demonstrated variable repeatability in healthy and glaucomatous eyes. Measurements obtained from the optic disk circle scan showed better repeatability than those obtained from the disk map. The GCC measurements exhibited good repeatability.
引用
收藏
页码:23 / 28
页数:6
相关论文
共 50 条
  • [1] The Repeatability of Retinal Layer Thickness Measurements with Spectral-Domain Optical Coherence Tomography in Normal Eyes
    Kang, Min Seok
    Yu, Seung-Young
    Kwak, Hyung Woo
    [J]. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (05): : 786 - 793
  • [2] Diagnostic accuracy of retinal nerve fiber layer, macular ganglion cell complex and optic nerve head measurements using spectral-domain optical coherence tomography
    Pollet-Villard, Frederic
    Chiquet, Christophe
    Romanet, Jean-Paul
    Aptel, Florent
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [3] Peripapillary Retinal Nerve Fiber Layer Thickness Determined by Spectral-Domain Optical Coherence Tomography in Ophthalmologically Normal Eyes
    Hirasawa, Hiroyo
    Tomidokoro, Atsuo
    Araie, Makoto
    Konno, Shinsuke
    Saito, Hitomi
    Iwase, Aiko
    Shirakashi, Motohiro
    Abe, Haruki
    Ohkubo, Shinji
    Sugiyama, Kazuhisa
    Ootani, Tomohiro
    Kishi, Shoji
    Matsushita, Kenji
    Maeda, Naoyuki
    Hangai, Masanori
    Yoshimura, Nagahisa
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2010, 128 (11) : 1420 - 1426
  • [4] Reproducibility of peripapillary retinal nerve fibre layer thickness measurements with spectral domain optical coherence tomography in normal and glaucomatous eyes
    Mansoori, Tarannum
    Viswanath, Kalluri
    Balakrishna, Nagalla
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (05) : 685 - 688
  • [5] Spectral Domain Optical Coherence Tomography of Ganglion Cell Complex and Retinal Nerve Fiber Layer in Multiple Sclerosis
    Calafiore, Silvia
    Scuderi, Gianluca
    Martino, Francesco
    Ducoli, Giorgio
    Delle Fave, Martina Maria
    Perdicchi, Andrea
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [6] Repeatability of Perimacular Ganglion Cell Complex Analysis with Spectral-Domain Optical Coherence Tomography
    Ng, Dorothy S. K.
    Gupta, Preeti
    Tham, Yih Chung
    Peck, Chye Fong
    Wong, Tien Yin
    Ikram, Mohammad Kamran
    Cheung, Carol Y.
    [J]. JOURNAL OF OPHTHALMOLOGY, 2015, 2015
  • [7] Comparison of Retinal Nerve Fiber Layer Thickness in Normal Eyes Using Time-Domain and Spectral-Domain Optical Coherence Tomography
    Seibold, Leonard K.
    Mandava, Naresh
    Kahook, Malik Y.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 150 (06) : 807 - 814
  • [8] Retinal nerve fiber layer and ganglion cell complex thicknesses measured with spectral-domain optical coherence tomography in eyes with no light perception due to nonglaucomatous optic neuropathy
    Atsuya Miki
    Takao Endo
    Takeshi Morimoto
    Kenji Matsushita
    Takashi Fujikado
    Kohji Nishida
    [J]. Japanese Journal of Ophthalmology, 2015, 59 : 230 - 235
  • [9] Estimating retinal nerve fiber layer thickness in normal schoolchildren with spectral-domain optical coherence tomography
    Tsai, Der-Chong
    Huang, Nicole
    Hwu, Jinn-Jong
    Jueng, Ruo-Nan
    Chou, Pesus
    [J]. JAPANESE JOURNAL OF OPHTHALMOLOGY, 2012, 56 (04) : 362 - 370
  • [10] Retinal nerve fiber layer and ganglion cell complex thicknesses measured with spectral-domain optical coherence tomography in eyes with no light perception due to nonglaucomatous optic neuropathy
    Miki, Atsuya
    Endo, Takao
    Morimoto, Takeshi
    Matsushita, Kenji
    Fujikado, Takashi
    Nishida, Kohji
    [J]. JAPANESE JOURNAL OF OPHTHALMOLOGY, 2015, 59 (04) : 230 - 235