Convenient hyaluronidase biosensors based on the target-trigger enhancing of the permeability of a membrane using an electronic balance as a readout

被引:5
|
作者
Dong, Nuo [1 ,2 ,3 ,4 ,5 ]
Cai, Qing [1 ,2 ]
Li, Zhixin [6 ]
Xu, Liangzhen [1 ,2 ]
Wu, Huping [1 ,2 ,5 ]
Lin, Zhirong [1 ,2 ,5 ]
Qiu, Bin [6 ]
Li, Cheng [1 ,2 ]
Lin, Zhenyu [6 ]
机构
[1] Xiamen Univ, Sch Med, Eye Inst, Xiamen, Fujian, Peoples R China
[2] Xiamen Univ, Sch Med, Affiliated Xiamen Eye Ctr, Xiamen, Fujian, Peoples R China
[3] Jiangsu Univ, Affiliated Peoples Hosp, Dept Ophthalmol, Zhenjiang, Jiangsu, Peoples R China
[4] Jiangsu Univ, Zhenjiang Kangfu Eye Hosp, Zhenjiang, Jiangsu, Peoples R China
[5] Fujian Prov Key Lab Ocular Surface & Corneal Dis, Xiamen, Fujian, Peoples R China
[6] Fuzhou Univ, Fujian Prov Key Lab Anal & Detect Food Safety, Key Lab Analyt Sci Food Safety & Biol, Minist Educ,Coll Chem, Fuzhou, Fujian, Peoples R China
基金
中国国家自然科学基金;
关键词
Electronic balances - Filtration systems - Limit of detection - Linear relationships - Micro porous membranes - Optimized conditions - Polyethyleneimine - Reaction conditions;
D O I
10.1039/d1an00257k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The change in hyaluronidase (HAase) is related to specific changes in the structure of vitreous, and it is necessary to develop simple but sensitive methods for HAase detection. In this work, a thin film fabricated from a hyaluronic acid (HA)-polyethyleneimine (PEI) hydrogel has been covered on a mixed cellulose microporous membrane (MCEM) to form a HA-PEI-MCEM firstly and it was then applied in a filtration system. The permeability of the filter membrane greatly affects the amount of water passing through within a certain time and the water can be collected and quantitatively measured with a simple electronic balance easily. The low permeability of the HA-PEI-MCEM allows a small amount of water to be drained. But after the addition of HAase, which can hydrolyze HA in the hydrogel, the permeability of the membrane increased. Therefore, the amount of water passing through the HA-PEI-MCEM composite membrane increased accordingly. The composite of the membrane, and the reaction conditions after the addition of HAase were optimized. Under the optimized conditions, the amount of water collected within 5 min showed a linear relationship with the HAase concentration in a range of 1.0-36 U mL(-1) with a limit of detection of 0.35 U mL(-1).The proposed method has been applied to detect HAase in vitreous samples with satisfactory results.
引用
收藏
页码:3299 / 3304
页数:6
相关论文
共 4 条
  • [1] Sensitive Hyaluronidase Biosensor Based on Target-Responsive Hydrogel Using Electronic Balance as Readout
    Li, Zhixin
    Tang, Caixi
    Huang, Da
    Qin, Wenjuan
    Luo, Fang
    Wang, Jian
    Guo, Longhua
    Qiu, Bin
    Lin, Zhenyu
    ANALYTICAL CHEMISTRY, 2019, 91 (18) : 11821 - 11826
  • [2] A Simple and Convenient Aptasensor for Protein Using an Electronic Balance as a Readout
    Wang, Alian
    Ma, Xiaoming
    Ye, Yanzhu
    Luo, Fang
    Guo, Longhua
    Qiu, Bin
    Lin, Zhenyu
    Chen, Guonan
    ANALYTICAL CHEMISTRY, 2018, 90 (02) : 1087 - 1091
  • [3] Determination of copper ions in herbal medicine based on click chemistry using an electronic balance as a readout
    Wu, Shuihua
    Cheng, Weiqing
    Li, Zhixin
    Luo, Fang
    Guo, Longhua
    Qiu, Bin
    Lin, Zhenyu
    ANALYTICAL METHODS, 2020, 12 (36) : 4473 - 4478
  • [4] Highly sensitive and selective aflatoxin B1 biosensor based on Exonuclease I-catalyzed target recycling amplification and targeted response aptamer-crosslinked hydrogel using electronic balances as a readout
    Tang, Linyue
    Huang, Yaying
    Lin, Cuiying
    Qiu, Bin
    Guo, Longhua
    Luo, Fang
    Lin, Zhenyu
    TALANTA, 2020, 214