Demonstration of structural performance of IP-2 packages by advanced analytical simulation and full-scale drop test

被引:8
|
作者
Kim, Kap-Sun [1 ]
Chung, Sung-Hwan [2 ]
Kim, Jong-Soo [1 ]
Choi, Kyu-Sup [1 ]
Yun, Hyun-Do [3 ]
机构
[1] Korea Nucl Engn & Serv Corp, Seoul 137130, South Korea
[2] Korea Hydro & Nucl Power Co Ltd, Taejon 305343, South Korea
[3] Chungnam Natl Univ, Dept Architectural Engn, Taejon 305764, South Korea
关键词
8;
D O I
10.1016/j.nucengdes.2009.11.035
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Two new types of IP-2 (Industrial Package Type 2) to transport low and intermediate level radioactive waste (LILW) steel drums from nuclear power plants to a disposal facility have been developed in accordance with the IAEA and Korean regulations for radioactive materials. According to the regulations, both packages must preserve their structural performance after they are subjected to 0.9 m free drop tests, which are prescribed as normal conditions. In this study, an advanced analytical simulation and an evaluation process using the finite element (FE) method have been developed for the design assessment of the newly developed IP-2s. Then, analytical simulations for the various drop orientations were performed to evaluate the structural performance of the packages and demonstrate their compliance with the regulatory requirements. Also, full-scale drop tests were carried out to verify the numerical tools and modeling methodology used in the analyses and to confirm the performance of the IP-2s. In addition, parametric studies are carried out to investigate the sensitivity of the analytical variables, such as the material model and modeling methodology. In addition, this paper intends to provide basic guidance on the analytical simulation and evaluation process specifically for Korean types of transport packages, because numerous transport packages must now be developed for the various kinds of LILW that have accumulated in temporary storage facilities in Korea. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:639 / 655
页数:17
相关论文
共 18 条
  • [1] Demonstration of structural performance of IP-2 package by simulation and full-scale horizontal free drop test
    Lo Frano, Rosa
    Sanfiorenzo, Antonio
    [J]. PROGRESS IN NUCLEAR ENERGY, 2016, 86 : 40 - 49
  • [2] Computer simulation of a full-scale structural fire test
    Bailey, C.G.
    Burgess, I.W.
    Plank, R.J.
    [J]. Structural engineer London, 1996, 74 (06): : 93 - 100
  • [3] Full-scale vertical drop test and numerical simulation of a crashworthy helicopter seat/occupant system
    Hu, D. Y.
    Yang, J. L.
    Hu, M. H.
    [J]. INTERNATIONAL JOURNAL OF CRASHWORTHINESS, 2009, 14 (06) : 565 - 583
  • [4] SIMULATION OF A FULL-SCALE CO2 FRACTURE PROPAGATION TEST
    Gruben, Gaute
    Dumoulin, Stephane
    Nordhagen, Hakon
    Hammer, Morten
    Munkejord, Svend T.
    [J]. PROCEEDINGS OF THE 12TH INTERNATIONAL PIPELINE CONFERENCE, 2018, VOL 3, 2018,
  • [5] FULL-SCALE TEST AND SIMULATION OF FITTINGS PERFORMANCE OF A CURRENT CRUDE OIL TANK CAR
    Gonzalez, Francisco, III
    Trent, Robert
    Gantoi, Florentina M.
    Prabhakaran, Anand
    [J]. PROCEEDINGS OF THE ASME JOINT RAIL CONFERENCE, 2018, 2018,
  • [6] Experimental study on structural performance of the new shaped weak-axis connection in full-scale test
    Eun-Taik Lee
    Min-Joung Kang
    Sung-Bae Kim
    Sang-Seup Kim
    [J]. International Journal of Steel Structures, 2016, 16 : 685 - 696
  • [7] Comparative Analysis of the Seismic Performance of a Full-Scale Historical Timber Structure by Numerical Simulation and Mechanical Test
    Chen, Jinyong
    Li, Tieying
    Yang, Qingshan
    Niu, Qingfang
    Shi, Xiwang
    Meng, Xianjie
    Wan, Jia
    Zhao, Yanxia
    [J]. INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE, 2024, 18 (05) : 740 - 749
  • [8] Experimental Study on Structural Performance of the New Shaped Weak-Axis Connection in Full-Scale Test
    Lee, Eun-Taik
    Kang, Min-Joung
    Kim, Sung-Bae
    Kim, Sang-Seup
    [J]. INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2016, 16 (03) : 685 - 696
  • [9] A SIMPLE ANALYTICAL METHOD FOR EVALUATION OF FLEXIBLE ROCKFALL BARRIER PART 2: APPLICATION AND FULL-SCALE TEST
    Yu, Z. X.
    Qiao, Y. K.
    Zhao, L.
    Xu, H.
    Zhao, S. C.
    Liu, Y. P.
    [J]. ADVANCED STEEL CONSTRUCTION, 2018, 14 (02): : 142 - 165
  • [10] Dynamic loading test and simulation analysis of full-scale semi-active hydraulic damper for structural control
    Niwa, Naoki
    Kobori, Takuji
    Takahashi, Motoichi
    Midorikawa, Hiroshi
    Kurata, Narito
    Mizuno, Takayuki
    [J]. 2000, John Wiley & Sons Ltd, Chichester (29)