Predictability of different calculators in the minimization of postoperative astigmatism after implantation of a toric intraocular lens

被引:22
|
作者
Ribeiro, Filomena J. [1 ,2 ]
Ferreira, Tiago B. [1 ,3 ]
Reha, Catarina [1 ]
Esteves, Carina [1 ]
Gaspar, Sylvia [1 ]
机构
[1] Luz Hosp, Ophthalmol Dept, Lisbon, Portugal
[2] Univ Lisbon, Fac Med, Lisbon, Portugal
[3] NOVA Med Sch, Lisbon, Portugal
来源
CLINICAL OPHTHALMOLOGY | 2019年 / 13卷
关键词
astigmatism; toric IOL; toric IOL calculation; TOTAL CORNEAL ASTIGMATISM; RESIDUAL REFRACTIVE ASTIGMATISM; CATARACT-SURGERY; INTRAOPERATIVE ABERROMETRY; CORRECTING ASTIGMATISM; PREDICTION; POWER; SCHEIMPFLUG; REPEATABILITY; TOPOGRAPHER;
D O I
10.2147/OPTH.S213132
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the efficacy of five calculators for toric intraocular lenses (IOL). Methods: Retrospective comparative case series in cataract patients undergoing implantation of trifocal toric IOLs (PhysIOL FineVision POD FT). Inclusion criteria were age-related cataract and a corneal astigmatism between 0.90D and 4.50D. Refractive astigmatism predictability of five different toric calculators or calculation methods were compared. Furthermore, two groups were differentiated according to the type of astigmatism. The mean absolute error and the centroid errors in the predicted residual astigmatism from each calculator were evaluated. Results: Fifty-one eyes of 43 patients were included in the study. For the standard toric calculator using anterior keratometry values only, the centroid prediction error was 0.39D +/- 0.41@166 degrees, which was reduced by the application of the PhysIOL toric calculator that includes the Abulafia-Koch regression formula and adjustment for the effective lens position (0.05D +/- 0.34@167 degrees), and also by the application of the Barrett toric calculator (0.07D +/- 0.28@160 degrees). Regarding the techniques that directly evaluate posterior corneal surface, the Holladay toric calculator, using total corneal power provided by a color-LED topographer, generated better results (0.10D +/- 0.44@156 degrees) than those using Scheimpflug camera data (0.23D +/- 0.56@158 degrees). Similar results were found for both types of astigmatism. Conclusion: The PhysIOL and the Barrett toric calculators taking into account the posterior corneal astigmatism by mathematical models, yielded lower astigmatic prediction errors compared to a standard toric calculator based on anterior keratometry data only. When total corneal power measurements were used, prediction errors were lower with color-LED than with Scheimpflug based topography.
引用
收藏
页码:1649 / 1656
页数:8
相关论文
共 50 条
  • [1] Predictability of Residual Postoperative Astigmatism After Implantation of a Toric Intraocular Lens Using Two Different Calculators
    Pantanelli, Seth M.
    Kansara, Neal
    Smits, Gerard
    [J]. CLINICAL OPHTHALMOLOGY, 2020, 14 : 3627 - 3634
  • [2] Residual astigmatism after toric intraocular lens implantation
    Berdahl, John P.
    Hardten, David R.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (04): : 730 - 731
  • [3] Postoperative astigmatism and rotational stability after Artisan toric phakic intraocular lens implantation
    Tehrani, M
    Dick, HB
    Schwenn, O
    Blom, E
    Schmidt, AH
    Koch, HR
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (09): : 1761 - 1766
  • [4] Prediction of postoperative refractive astigmatism before toric intraocular lens implantation
    Kawahara, Atsushi
    [J]. BMC OPHTHALMOLOGY, 2021, 21 (01)
  • [5] Prediction of postoperative refractive astigmatism before toric intraocular lens implantation
    Atsushi Kawahara
    [J]. BMC Ophthalmology, 21
  • [6] Residual astigmatism after toric intraocular lens implantation Reply
    Felipe, Adelina
    Artigas, Jose M.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (04): : 731 - 732
  • [7] Accuracy of Toric Intraocular Lens Calculators with Predicted and Measured Posterior Corneal Astigmatism Across Different Types of Astigmatism
    Yang, Soonwon
    Park, Jaehyun
    Whang, Woong Joo
    Byun, Yong-Soo
    Kim, Hyun Seung
    Chung, So-Hyang
    [J]. OPHTHALMOLOGY AND THERAPY, 2024, 13 (07) : 1877 - 1889
  • [8] Postoperative Results after Implantation of a Toric, Aspheric Intraocular Lens
    Khoramnia, R.
    Fitting, A.
    Rabsilber, T. M.
    Auffarth, G. U.
    Holzer, M. P.
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2015, 232 (07) : 867 - 873
  • [9] Evaluation of Factors Influencing the Remaining Astigmatism After Toric Intraocular Lens Implantation
    Hirnschall, Nino
    Hoffmann, Peter C.
    Draschl, Petra
    Maedel, Sophie
    Findl, Oliver
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (06) : 394 - +
  • [10] Vector analysis after toric intraocular lens implantation to correct astigmatism Reply
    Dexl, Alois K.
    Grabner, Guenther
    Krall, Eva M.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (06): : 1339 - 1340