Comparison of CFRP and GFRP Wraps on Reducing Seismic Damage of Deficient Reinforced Concrete Structures

被引:19
|
作者
Vui Van Cao [1 ]
Son Quang Pham [1 ]
机构
[1] Vietnam Natl Univ, Ho Chi Minh City Univ Technol HCMUT, Fac Civil Engn, Mech Mat & Struct Lab,Dept Mech Mat & Struct, 268 Ly Thuong Kiet St,Dist 10, Ho Chi Minh City, Vietnam
关键词
Retrofitting; CFRP; GFRP; Seismic damage; RC frame; Confinement; STRESS-STRAIN MODEL; RECTANGULAR RC COLUMNS; CONFINED CONCRETE; COMPRESSIVE BEHAVIOR; FRP CONFINEMENT; DESIGN; STEEL; PERFORMANCE; BUILDINGS; POLYMER;
D O I
10.1007/s40999-019-00429-y
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The effectiveness of glass/carbon fibre reinforced polymer (GFRP/CFRP) wraps at plastic hinges has been confirmed; however, their respective effectiveness on reducing seismic damage of deficient reinforced concrete structures has hardly been compared. The current study aims at this comparison, providing some useful information to realise the better FRP for confinement retrofitting of reinforced concrete structures poorly confined due to deficient transverse reinforcement. Four- and eight-storey poorly confined reinforced concrete frames were selected to represent low- and mid-rise building structures, respectively. These deficient frames were then strengthened by CFRP/GFRP wraps via external confinement. Inelastic time history and cumulative damage analyses of the original, CFRP- and GFRP-retrofitted frames were performed. The damages of CFRP- and GFRP-retrofitted frames were compared with each other and with the damage of the original frame. The comparison results show that CFRP and GFRP wraps at plastic hinges substantially reduce damage. More importantly, GFRP wraps are more effective than CFRP wraps by reducing a higher amount of the cumulative damage index. The conclusions can help in deciding on the type of FRP to be used for confinement retrofitting of RC structures poorly confined due to deficient transverse reinforcement.
引用
收藏
页码:1667 / 1681
页数:15
相关论文
共 50 条
  • [1] Comparison of CFRP and GFRP Wraps on Reducing Seismic Damage of Deficient Reinforced Concrete Structures
    Vui Van Cao
    Son Quang Pham
    [J]. International Journal of Civil Engineering, 2019, 17 : 1667 - 1681
  • [2] Effects of CFRP/GFRP flexural retrofitting on reducing seismic damage of reinforced concrete frames: a comparative study
    Van Cao V.
    Quoc Nguyen T.
    [J]. Asian Journal of Civil Engineering, 2019, 20 (8) : 1071 - 1087
  • [3] SEISMIC DAMAGE ASSESSMENT OF DEFICIENT REINFORCED CONCRETE FRAME STRUCTURES
    Rizwan, Muhammad
    Shah, Syed Azmat Ali
    [J]. CIVIL AND ENVIRONMENTAL ENGINEERING, 2021, 17 (01) : 31 - 44
  • [4] Effects of CFRP U-Wraps on the Behavior of NSM GFRP Retrofitted Reinforced Concrete Beams
    Cao, Vui Van
    [J]. Journal of Composites for Construction, 2025, 29 (01)
  • [5] Analytical and Experimental Study on Upgrading the Seismic Performance of Reinforced Masonry Columns Using GFRP and CFRP Wraps
    Ashour, Ahmed
    Galal, Khaled
    Farnia, Nima
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2018, 22 (04)
  • [6] Simulation of Reinforced Concrete Columns Strengthened with CFRP Wraps
    Khan, Asad-ur-Rehman
    Nasir, Rida
    Fareed, Shamsoon
    [J]. INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2023, 21 (02) : 299 - 313
  • [7] Simulation of Reinforced Concrete Columns Strengthened with CFRP Wraps
    Asad-ur-Rehman Khan
    Rida Nasir
    Shamsoon Fareed
    [J]. International Journal of Civil Engineering, 2023, 21 : 299 - 313
  • [8] Damage-Based Seismic Retrofitting Approach for Nonductile Reinforced Concrete Structures Using FRP Composite Wraps
    Cao, Vui Van
    Pham, Son Quang
    [J]. ADVANCES IN CIVIL ENGINEERING, 2020, 2020
  • [9] Seismic Response Analysis of CFRP Retrofitted Reinforced Concrete Structures
    Jin Bo
    Zu Defeng
    Wu Hansheng
    Gao Yongwu
    [J]. CONSTRUCTION AND URBAN PLANNING, PTS 1-4, 2013, 671-674 : 1445 - 1457
  • [10] Shear Strengthening of Reinforced Concrete Beams Using GFRP Wraps
    Saafan, M. A. A.