Impact of Sterilization on a Conjugated Polymer-Based Bioelectronic Patch

被引:2
|
作者
Yan, Yihan [1 ,2 ]
Travaglini, Lorenzo [1 ,2 ]
Lau, Kieran [3 ]
Rnjak-Kovacina, Jelena [3 ]
Ta, Daniel [4 ]
Eslami, Minoo [1 ,2 ]
Yang, Shaohua [1 ]
Lauto, Antonio [4 ]
Officer, David [5 ,6 ]
Mawad, Damia [7 ,8 ]
机构
[1] UNSW Sydney, Sch Mat Sci & Engn, Sydney, NSW 2052, Australia
[2] UNSW Sydney, Ctr Adv Macromol Design, Sydney, NSW 2052, Australia
[3] Univ New South Wales, Grad Sch Biomed Engn, Sydney, NSW 2052, Australia
[4] Western Sydney Univ, Sch Sci, Penrith, NSW 2751, Australia
[5] Univ Wollongong, AIIM Fac, ARC Ctr Excellence Electromat Sci, Wollongong, NSW 2522, Australia
[6] Univ Wollongong, AIIM Fac, Intelligent Polymer Res Inst, Wollongong, NSW 2522, Australia
[7] UNSW Sydney, Ctr Adv Macromol Design, Sch Mat Sci & Engn, Sydney, NSW 2052, Australia
[8] UNSW Sydney, ARC Ctr Excellence Convergent Bionano Sci & Techn, Sydney, NSW 2052, Australia
基金
澳大利亚研究理事会;
关键词
polyaniline; bioelectronic; sterilization; gamma; ethylene oxide; SYNTHESIZED CONDUCTING POLYANILINE; ELECTRICAL-CONDUCTIVITY; CHEMICAL DEGRADATION; GAMMA-IRRADIATION; IN-VITRO; RADIATION; XPS; BIOMATERIALS; STABILITY; SURFACE;
D O I
10.1021/acsapm.1c00131
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Organic bioelectronics based on conjugated polymers as the active electronic material have been shown to operate efficiently at the biointerface. Their translation into a commercial medical device will hinge on their long-term operation in vivo. This will require the device to be subjected to clinically approved sterilization techniques without deterioration in its physical and electronic properties. To date, there remains a gap in the literature addressing the impact of this critical preoperative procedure on the properties of conjugated polymers. This study aims to address this gap by assessing the physical and electronic properties of a sterilized porous bioelectronic patch having polyaniline as the conjugated polymer. The patch was sterilized by autoclave, ethylene oxide, and gamma (gamma-) irradiation at 15, 25, and 50 kGy doses. Autoclaving resulted in cracking and macroscopic degradation of the patch, while patches sterilized by gamma-irradiation at 50 kGy exhibited reduced mechanical and electronic properties, attributed to chain scission and nonuniform cross-linking caused by high dose irradiation. Ethylene oxide and gamma-irradiation at 15 and 25 kGy sterilization appeared to be the most effective at maintaining the mechanical and electronic properties of the patch and inducing a minimal immune response as revealed by a receding fibrotic capsule after 4 week implantation. Our findings pave the way toward closing the gap for the translation of organic bioelectronic devices from acute to long-term in vivo models.
引用
收藏
页码:2541 / 2552
页数:12
相关论文
共 50 条
  • [1] Impact of Sterilization Method on Protein Aggregation and Particle Formation in Polymer-Based Syringes
    Kiminami, Hideaki
    Krueger, Aaron B.
    Abe, Yoshihiko
    Yoshino, Keisuke
    Carpenter, John F.
    [J]. JOURNAL OF PHARMACEUTICAL SCIENCES, 2017, 106 (04) : 1001 - 1007
  • [2] Conjugated polymer-based chemical sensors
    McQuade, DT
    Pullen, AE
    Swager, TM
    [J]. CHEMICAL REVIEWS, 2000, 100 (07) : 2537 - 2574
  • [3] Conjugated polymer-based photonic nanostructures
    O'Carroll, Deirdre M.
    Petoukhoff, Christopher E.
    Kohl, Jesse
    Yu, Binxing
    Carter, Catrice M.
    Goodman, Sarah
    [J]. POLYMER CHEMISTRY, 2013, 4 (20) : 5181 - 5196
  • [4] π-Conjugated polymer-based chemical sensors
    Minami, Tsuyoshi
    [J]. FRONTIERS IN BIOLOGICAL DETECTION:FROM NANOSENSORS TO SYSTEMS XVI, 2024, 12861
  • [5] Natural polymer-based bioabsorbable conducting wires for implantable bioelectronic devices
    Niu, Qianqian
    Huang, Xiangyu
    Lv, Shasha
    Yao, Xiang
    Fan, Suna
    Zhang, Yaopeng
    [J]. JOURNAL OF MATERIALS CHEMISTRY A, 2020, 8 (47) : 25323 - 25335
  • [6] Sterilization of implantable polymer-based medical devices: A review
    Tipnis, Namita P.
    Burgess, Diane J.
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2018, 544 (02) : 455 - 460
  • [7] Polymer-based 2.4 GHz Patch Antenna
    Song, Yuchan
    Le Goff, Denis
    Riondet, Ghislain
    Mouthaan, Koen
    [J]. 2020 INTERNATIONAL WORKSHOP ON ANTENNA TECHNOLOGY (IWAT), 2020,
  • [8] Flexible bioelectronic device fabricated by conductive polymer-based living material
    Wang, Zenghao
    Bai, Haotian
    Yu, Wen
    Gao, Zhiqiang
    Chen, Weijian
    Yang, Zhiwen
    Zhu, Chuanwei
    Huang, Yiming
    Lv, Fengting
    Wang, Shu
    [J]. SCIENCE ADVANCES, 2022, 8 (25)
  • [9] Conjugated polymer-based light emitting diodes
    Towns, C. R.
    Grizzi, I.
    Roberts, M.
    Wehrum, A.
    [J]. JOURNAL OF LUMINESCENCE, 2007, 122 : 976 - 979
  • [10] A review on conjugated polymer-based electronic tongues
    Vahdatiyekta, Parastoo
    Zniber, Mohammed
    Bobacka, Johan
    Huynh, Tan-Phat
    [J]. ANALYTICA CHIMICA ACTA, 2022, 1221