Quantitative Analysis and Simple Monitoring for Partial Discharge from Transformer

被引:0
|
作者
Kwak, Seung Soo [1 ]
Kim, Yong Sin [1 ]
机构
[1] Korea Univ, Dept Elect Engn, Seoul, South Korea
关键词
Transformer; partial discharge; monitoring; POWER TRANSFORMERS; DIAGNOSIS;
D O I
10.1109/ICEIC51217.2021.9369769
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
The various signals are output such as partial discharge, vibration, ultrasonic waves, and acoustic emission when the transformers have deformation or abnormality. These signals need to be monitored since they are important signals to notice the transformer failure. To prevent this, the monitoring system of transformer uses a high-speed data acquisition system to extract various physical quantities from the raw abnormal signal. Among the types of abnormal signals, partial discharge (PD) is caused by failure of the insulator, which has a great influence on the life and maintenance of the transformer. In this paper, a PD signal is mimicked by using a PD generator to analyze the partial discharge of a transformer. PD signal is simply analyzed by fast Fourier transform. Also, by proposing a simple monitoring system, it is introduced that a communication method of root-mean-square (RMS) value, maximum value, and maximum RMS value.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Quantitative analysis and evaluation of the optimization method of transformer partial discharge ultrasonic sensor monitoring
    Jiang, Youhua
    Shang, Xingsen
    Jiang, Xiangwei
    Chen, Bo
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2023, 34 (11)
  • [3] Online Partial Discharge Monitoring and Failure Analysis of a 132 kV Current Transformer
    Ward, Brody
    Whyte, Thomas
    [J]. 2021 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2021, : 373 - 376
  • [4] Experiment analysis of influence of external coupling network on partial discharge monitoring of transformer
    Wang, J
    Li, FQ
    Wang, ZD
    [J]. PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 & 2, 2000, : 672 - 675
  • [5] The analysis of ultrasonic signals by partial discharge and noise from the transformer
    Kweon, DJ
    Chin, SB
    Kwak, HR
    Kim, JC
    Song, KB
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (03) : 1976 - 1983
  • [6] On-line Monitoring System for Transformer Partial Discharge
    Liu, Guangya
    Kang, Lu
    Peng, Weina
    [J]. SENSORS, MEASUREMENT AND INTELLIGENT MATERIALS, PTS 1-4, 2013, 303-306 : 464 - 467
  • [7] An On-line Monitoring System for Partial Discharge from High Voltage Transformer
    王哲
    陈学允
    蔡惟铮
    [J]. Journal of Harbin Institute of Technology(New series), 1998, (02) : 52 - 56
  • [8] Transformer partial discharge monitoring based on optical fiber sensing
    Wang K.
    Tong X.
    Zhu X.
    [J]. Photonic Sensors, 2014, 4 (02) : 137 - 141
  • [9] Analysis of Partial Discharge Test of Transformer Caused by Excitation Transformer Fault
    Bing, Yu
    Lin, Zhao
    Zhi, Yang
    Yong, Yang
    [J]. 2019 IEEE 4TH INTERNATIONAL CONFERENCE ON INTEGRATED CIRCUITS AND MICROSYSTEMS (ICICM 2019), 2019, : 114 - 117
  • [10] Partial Discharge Monitoring of Dry Distribution Transformer Based on Grid Search Scheme and Characteristic Analysis
    Chen, Yang