In Vivo 3-D Dose Verification Using PET/CT Images After Carbon-Ion Radiation Therapy

被引:3
|
作者
Sun, Lining [1 ,2 ]
Hu, Weigang [1 ,2 ]
Lai, Songtao [1 ,2 ]
Shi, Leijun [3 ]
Chen, Junchao [1 ,2 ]
机构
[1] Fudan Univ, Dept Radiat Oncol, Shanghai Canc Ctr, Shanghai, Peoples R China
[2] Fudan Univ, Shanghai Med Coll, Dept Oncol, Shanghai, Peoples R China
[3] Shanghai Proton & Heavy Ion Ctr, Dept Nucl Med, Shanghai, Peoples R China
来源
FRONTIERS IN ONCOLOGY | 2021年 / 11卷
关键词
carbon ion; radiation therapy; positron emission tomography; standard uptake value; dose verification; RANGE VERIFICATION; PROTON; BEAMS;
D O I
10.3389/fonc.2021.621394
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective To investigate the usefulness of positron emission tomography (PET) images obtained after carbon-ion irradiation for dose verification in carbon-ion radiotherapy. Methods and Materials An anthropomorphic head phantom was used in this study. Three cubes with volumes of 1, 4, and 10 ml were contoured as targets in the phantom CT through a treatment planning system. Treatment plans with six prescriptions from 2.5 to 10 Gy (2.5, 3, 5, 6, 8, and 10 Gy effective dose) were designed and delivered by 90 degrees fixed carbon-ion beams, respectively. After irradiation of the phantom, a PET/CT scan was performed to fuse the treatment-planning CT image with the PET/CT image. The relationship between target volume and the standard uptake value (SUV) in PET/CT was evaluated for corresponding plan prescription. The MIM Maestro software was used for the image fusion and data analysis. Results SUV in the target had an approximate linear relationship with the effective dose. The same effective dose could generate a roughly equal SUV for different target volumes (p < 0.05). Conclusions It is feasible to verify the actual 3-D dose distribution of carbon-ion radiotherapy by the approach in this study.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] A Research of PET-CT SUV Range for the Online Dose Verification in Carbon Ion Radiation Therapy
    Sun, L.
    Hu, W.
    Moyers, M.
    Zhao, J.
    Hsi, W.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3298 - 3298
  • [2] In vivo verification of dose delivery to prostate cancer by utilizing PET/CT images taken after proton therapy
    Lin, L.
    Hsi, W.
    Indelicato, D.
    Vargas, C.
    Flampouri, S.
    Slopesema, R.
    Keole, S. R.
    Li, Z.
    Yeung, D.
    Palta, J. R.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S144 - S144
  • [3] Development of a compact dose verification system using a fluorescent screen for carbon-ion therapy
    Yousuke Hara
    Takuji Furukawa
    Kota Mizushima
    Naoya Saotome
    Yuichi Saraya
    Ryohei Tansho
    Toshiyuki Shirai
    Koji Noda
    Eri Takeshita
    [J]. Journal of the Korean Physical Society, 2016, 69 : 1014 - 1018
  • [4] Development of a compact dose verification system using a fluorescent screen for carbon-ion therapy
    Hara, Yousuke
    Furukawa, Takuji
    Mizushima, Kota
    Saotome, Naoya
    Saraya, Yuichi
    Tansho, Ryohei
    Shirai, Toshiyuki
    Noda, Koji
    Takeshita, Eri
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2016, 69 (06) : 1014 - 1018
  • [5] PET-CT: Evolving role in 3-D radiation therapy
    Levy, RP
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2006, 5 (02) : 101 - 107
  • [6] FLT-PET/CT for Lung Cancer Patients Receiving Carbon-Ion Radiation Therapy: Prognostic Significance
    Saga, T.
    Koizumi, M.
    Inubushi, M.
    Yoshikawa, K.
    Fukumura, T.
    Baba, M.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S332 - S332
  • [7] Evaluation of Bone Marrow Activity after Carbon-Ion Radiotherapy by PET/CT Using a Proliferative Tracer, FLT
    Koizumi, M.
    Saga, T.
    Inubushi, M.
    Yoshikawa, K.
    Fukumura, T.
    Baba, M.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S351 - S351
  • [8] INTEGRATED 3-D DISPLAY OF MR, CT, AND PET IMAGES OF THE BRAIN
    LEVIN, DN
    HU, XP
    TAN, KK
    GALHOTRA, S
    HERRMANN, A
    CHEN, GTY
    PELIZZARI, CA
    BALTER, J
    BECK, RN
    CHEN, CT
    COOPER, MD
    [J]. NCGA 89 CONFERENCE PROCEEDINGS, VOLS 1-3, 1989, : A179 - A186
  • [9] Clinical target volume design and dose in carbon-ion radiation therapy for sinonasal mucosal melanoma
    Yang, Wan-Chin
    Koto, Masashi
    Ikawa, Hiroaki
    Imai, Reiko
    Shinoto, Makoto
    Takiyama, Hirotoshi
    Isozaki, Tetsuro
    Yamada, Shigeru
    [J]. RADIOTHERAPY AND ONCOLOGY, 2024, 200
  • [10] Dose reconstruction from PET images in carbon ion therapy: a deconvolution approach
    Hofmann, T.
    Pinto, M.
    Mohammadi, A.
    Nitta, M.
    Nishikido, F.
    Iwao, Y.
    Tashima, H.
    Yoshida, E.
    Chacon, A.
    Safavi-Naeini, M.
    Rosenfeld, A.
    Yamaya, T.
    Parodi, K.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (02):