Haemodynamics and blood flow measured using ultrasound imaging

被引:20
|
作者
Hoskins, P. R. [1 ]
机构
[1] Univ Edinburgh, Dept Med Phys, Edinburgh EH16 4SB, Midlothian, Scotland
关键词
two dimensional; three dimensional; four dimensional; arteries; blood flow; computational fluid dynamics; colour flow; Doppler ultrasound; echo particle image velocimetry; flow field; heart; turbulence; ultrasound; velocity; wall shear stress; COMMON CAROTID-ARTERY; WALL SHEAR-STRESS; 3-DIMENSIONAL DOPPLER-ECHOCARDIOGRAPHY; COMPUTATIONAL FLUID-DYNAMICS; COLOR DOPPLER; REAL-TIME; PULSATILE FLOW; MAXIMUM VELOCITY; IN-VIVO; STROKE VOLUME;
D O I
10.1243/09544119JEIM572
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Visualization of, and measurements related to, haemodynamic phenomena in arteries may be made using ultrasound systems. Most ultrasound technology relies on simple measurements of blood velocity taken from a single site, such as the peak systolic velocity for assessment of the degree of lumen reduction caused by an arterial stenosis. Real-time two-dimensional (2D) flow field visualization is possible using several methods, such as colour flow, blood flow imaging, and echo particle image velocimetry; these have applications in the examination of the flow field in diseased arteries and in heart chambers. Three-dimensional (3D) and four-dimensional ultrasound systems have been described. These have been used to provide 2D velocity profile data for the estimation of volumetric flow. However, they are limited for haemodynamic evaluation in that they provide only one component of the velocity. The provision of all seven components (three space, three velocity, and one time) is possible using image-guided inodelling, in which 3D ultrasound is combined with computational fluid dynamics. This method also allows estimation Of turbulence data and of relevant quantities Such as the wall shear stress.
引用
收藏
页码:255 / 271
页数:17
相关论文
共 50 条
  • [1] Cerebral blood flow can be accurately measured using contrast enhanced ultrasound imaging
    Rim, SJ
    Leong-Poi, H
    Bin, JP
    Lindner, JR
    Couture, D
    Ellegala, D
    Mason, H
    Durieux, M
    Kaul, S
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 406A - 406A
  • [2] Neural correlates of blood flow measured by ultrasound
    Nunez-Elizalde, Anwar O.
    Krumin, Michael
    Reddy, Charu Bai
    Montaldo, Gabriel
    Urban, Alan
    Harris, Kenneth D.
    Carandini, Matteo
    NEURON, 2022, 110 (10) : 1631 - +
  • [3] Investigation of blood under pulsatile flow using ultrasound imaging
    Paeng, DG
    Choi, MJ
    Shung, KK
    STATE OF THE ART: ULTRASONICS IN MEDICINE, 2004, 1274 : 99 - 108
  • [4] RECENT ADVANCES IN IMAGING AND EVALUATION OF BLOOD-FLOW USING ULTRASOUND
    PERSSON, AV
    POWIS, RL
    MEDICAL CLINICS OF NORTH AMERICA, 1986, 70 (06) : 1241 - 1252
  • [5] Ultrasound Imaging and Measurement of Choroidal Blood Flow
    Urs, Raksha
    Ketterling, Jeffrey A.
    Yu, Alfred C. H.
    Lloyd, Harriet O.
    Yiu, Billy Y. S.
    Silverman, Ronald H.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2018, 7 (05):
  • [6] In vivo imaging of ocular blood flow using high-speed ultrasound
    Ketterling, Jeffrey A.
    Urs, Raksha
    Silverman, Ronald H.
    2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [7] Blood flow imaging and volume flow quantitation with intravascular ultrasound
    Thoraxcentre, Erasmus University Rotterdam, Rotterdam, Netherlands
    不详
    不详
    不详
    Ultrasound Med. Biol., 2 (203-214):
  • [8] Blood flow imaging and volume flow quantitation with intravascular ultrasound
    Li, WG
    van der Steen, AFW
    Lancee, CT
    Cespedes, I
    Bom, N
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (02): : 203 - 214
  • [9] Pulsating renal blood flow distribution measured using power Doppler ultrasound: Correlation with hypertension
    Nagao, M
    Murase, K
    Saeki, H
    Mochizuki, T
    Sugata, S
    Ikezoe, J
    HYPERTENSION RESEARCH, 2002, 25 (05) : 697 - 702
  • [10] In vitro blood flow and cross-section indices measured using transcranial Doppler ultrasound
    Wallace, S.
    Faiz, K.
    Logallo, N.
    Lund, C.
    EUROPEAN JOURNAL OF NEUROLOGY, 2010, 17 : 409 - 409