Computer-Aided Volumetry of Pulmonary Nodules Exhibiting Ground-Glass Opacity at MDCT

被引:81
|
作者
Oda, Seitaro [1 ]
Awai, Kazuo [1 ]
Murao, Kohei [2 ]
Ozawa, Akio [2 ]
Yanaga, Yumi [1 ]
Kawanaka, Koichi [1 ]
Yamashita, Yasuyuki [1 ]
机构
[1] Kumamoto Univ, Grad Sch Med Sci, Dept Diagnost Radiol, Kumamoto 8608556, Japan
[2] Fujitsu, Bio IT Business Dev Grp, Tokyo, Japan
关键词
computer-aided diagnosis; ground-glass opacity; high-resolution CT; pulmonary nodules; volumetry; THIN-SECTION CT; DOSE HELICAL CT; HISTOLOGIC CHARACTERISTICS; AUTOMATED VOLUMETRY; LUNG NODULES; GROWTH-RATE; ADENOCARCINOMA; SEGMENTATION; ACCURACY; REPRODUCIBILITY;
D O I
10.2214/AJR.09.2583
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to investigate the accuracy and reproducibility of results acquired with computer-aided volumetry software during MDCT of pulmonary nodules exhibiting ground-glass opacity. MATERIALS AND METHODS. To evaluate the accuracy of computer-aided volumetry software, we performed thin-section helical CT of a chest phantom that included simulated 3-, 5-, 8-, 10-, and 12-mm-diameter ground-glass opacity nodules with attenuation of -800, -630, and -450 HU. Three radiologists measured the volume of the nodules and calculated the relative volume measurement error, which was defined as follows: ( measured nodule volume minus assumed nodule volume divided by assumed nodule volume) x 100. Two radiologists performed two independent measurements of 59 nodules in humans. Intraobserver and inter-observer agreement was evaluated with Bland-Altman methods. RESULTS. The relative volume measurement error for simulated ground-glass opacity nodules measuring 3 mm ranged from 51.1% to 85.2% and for nodules measuring 5 mm or more in diameter ranged from -4.1% to 7.1%. In the clinical study, for intraobserver agreement, the 95% limits of agreement were -14.9% and -13.7% and -16.6% to 15.7% for observers A and B. For interobserver agreement, these values were -16.3% to 23.7% for nodules 8 mm in diameter or larger. CONCLUSION. With computer-aided volumetry of ground-glass opacity nodules, the relative volume measurement error was small for nodules 5 mm in diameter or larger. Intraobserver and interobserver agreement was relatively high for nodules 8 mm in diameter or larger.
引用
收藏
页码:398 / 406
页数:9
相关论文
共 50 条
  • [1] Computer-aided diagnosis of ground-glass opacity pulmonary nodules using radiomic features analysis
    Gong, Jing
    Liu, Jiyu
    Hao, Wen
    Nie, Shengdong
    Wang, Shengping
    Peng, Weijun
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (13):
  • [2] Computer-Aided Segmentation and Volumetry of Artificial Ground-Glass Nodules at Chest CT
    Scholten, Ernst Th.
    Jacobs, Colin
    van Ginneken, Bram
    Willemink, Martin J.
    Kuhnigk, Jan-Martin
    van Ooijen, Peter M. A.
    Oudkerk, Matthijs
    Mali, Willem P. Th. M.
    de Jong, Pim A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (02) : 295 - 300
  • [3] Efficient computer-aided detection of ground-glass opacity nodules in thoracic CT images
    Ye, Xujiong
    Lin, Xinyu
    Beddoe, Gareth
    Dehmeshki, Jamshid
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 4449 - 4452
  • [4] Impalpable pulmonary nodules with ground-glass opacity
    Ikeda, Koei
    Nomori, Hiroaki
    Mori, Takeshi
    Kobayashi, Hironori
    Iwatani, Kazunori
    Yoshimoto, Kentaro
    Kawanaka, Ko-ichi
    CHEST, 2007, 131 (02) : 502 - 506
  • [5] A new scheme for computer-aided detection of CT lung nodules designed in consideration of ground-glass opacity
    Matsumoto, Sumiaki
    Ohno, Yoshiharu
    Yamagata, Hitoshi
    Asahina, Hiroshi
    Sugimura, Kazuro
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2006, 1 : 352 - 354
  • [6] Optimal management of pulmonary ground-glass opacity nodules
    Kim, Yeon Wook
    Lee, Choon-Taek
    TRANSLATIONAL LUNG CANCER RESEARCH, 2019, 8 : S418 - S424
  • [7] Volume-Doubling Time of Pulmonary Nodules with Ground Glass Opacity at Multidetector CT: Assessment with Computer-Aided Three-Dimensional Volumetry
    Oda, Seitaro
    Awai, Kazuo
    Murao, Kohei
    Ozawa, Akio
    Utsunomiya, Daisuke
    Yanaga, Yumi
    Kawanaka, Koichi
    Yamashita, Yasuyuki
    ACADEMIC RADIOLOGY, 2011, 18 (01) : 63 - 69
  • [8] Computer-Aided Diagnosis of Ground-Glass Opacity Nodules Using Open-Source Software for Quantifying Tumor Heterogeneity
    Li, Ming
    Narayan, Vivek
    Gill, Ritu R.
    Jagannathan, Jyothi P.
    Barile, Maria F.
    Gao, Feng
    Bueno, Raphael
    Jayender, Jagadeesan
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 209 (06) : 1216 - 1227
  • [9] Computer-aided diagnosis of localized ground-glass opacity in the lung at CT: Initial experience
    Kim, KG
    Goo, JM
    Kim, JH
    Lee, HJ
    Min, BG
    Bae, KT
    Im, JG
    RADIOLOGY, 2005, 237 (02) : 657 - 661
  • [10] Lymphadenectomy is Unnecessary for Pure Ground-Glass Opacity Pulmonary Nodules
    Lin, Yi-Han
    Chen, Chun-Ku
    Hsieh, Chih-Cheng
    Hsu, Wen-Hu
    Wu, Yu-Chung
    Hung, Jung-Jyh
    Hsu, Po-Kuei
    Hsu, Han-Shui
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (03)