Objective Evaluation of Functionality of Filtering Bleb Based on Polarization-Sensitive Optical Coherence Tomography

被引:20
|
作者
Kasaragod, Deepa [1 ]
Fukuda, Shinichi [2 ]
Ueno, Yuta [2 ]
Hoshi, Sujin [2 ]
Oshika, Tetsuro [2 ]
Yasuno, Yoshiaki [1 ]
机构
[1] Univ Tsukuba, Computat Opt Grp, Tsukuba, Ibaraki 3050821, Japan
[2] Univ Tsukuba, Fac Med, Dept Ophthalmol, Tsukuba, Ibaraki 3050821, Japan
基金
日本学术振兴会;
关键词
polarization-sensitive optical coherence tomography; birefringence; fibrosis; trabeculectomy; bleb; anterior segment; glaucoma filtration surgery; ANTERIOR-SEGMENT; PHASE RETARDATION; EYE; SURGERY; FILTRATION;
D O I
10.1167/iovs.15-18178
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. The fibrosis score is a new diagnostic score that we have developed to evaluate the function of bleb structures after glaucoma filtration surgery using polarization-sensitive optical coherence tomography (PS-OCT). This study aims to assess the efficacy of the fibrosis score in discriminating nonfunctional from the functional blebs. METHODS. A total of 20 patients who had undergone glaucoma filtration surgery were imaged at different time periods after surgery using PS-OCT. Birefringence tomography of blebs was obtained from PS-OCT, and the fibrosis score was computed for each patient. The fibrosis score is defined as the area of occupation of high birefringence area in the conjunctiva. The blebs were classified as functional or nonfunctional according to the IOP and the application of medication. The power of the fibrosis score to discriminate nonfunctional blebs from functional blebs was evaluated. RESULTS. The difference in the mean fibrosis score between the functional and nonfunctional bleb group was statistically significant. The fibrosis score showed good ability to discriminate nonfunctional from functional blebs. The area under the receiver operating characteristic curve was 0.82. The best combination of the sensitivity and specificity was 67% and 100%, respectively, for classifying nonfunctional cases. CONCLUSIONS. The fibrosis score showed a high ability to discriminate nonfunctional from functional blebs. Polarization-sensitive OCT is a noninvasive technique that provides not only the fibrosis score but also standard structural tomography. It can be a comprehensive tool for longitudinal evaluation after filtration surgery for glaucoma.
引用
收藏
页码:2305 / 2310
页数:6
相关论文
共 50 条
  • [1] Longitudinal changes in the fibrosis score of filtering bleb using polarization-sensitive optical coherence tomography
    Ueno, Yuta
    Kasaragod, Deepa
    Hoshi, Sujin
    Fujita, Akari
    Okubo, Tomotaka
    Fukuda, Shinichi
    Yasuno, Yoshiaki
    Oshika, Tetsuro
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [2] Objective evaluation of choroidal melanin contents with polarization-sensitive optical coherence tomography
    Miura, Masahiro
    Makita, Shuichi
    Yasuno, Yoshiaki
    Ikuno, Yasushi
    Uematsu, Sato
    Iwasaki, Takuya
    Goto, Hiroshi
    [J]. OPHTHALMIC TECHNOLOGIES XXVIII, 2018, 10474
  • [3] Evaluation of photodamage with polarization-sensitive optical coherence tomography
    Nguyen Hoang Trung
    Lee, Cheng-Yu
    Tsai, Meng-Tsan
    [J]. BIOMEDICAL IMAGING AND SENSING CONFERENCE, 2018, 10711
  • [4] Optical polarization tractography based on polarization-sensitive optical coherence tomography
    Yao, Gang
    Wang, Yuanbo
    Ravanfar, Mohammadreza
    Azinfar, Leila
    Yao, Xuan
    Zhang, Keqing
    Duan, Dongsheng
    [J]. OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XX, 2016, 9697
  • [5] Quantitative Evaluation of Phase Retardation in Filtering Blebs Using Polarization-Sensitive Optical Coherence Tomography
    Fukuda, Shinichi
    Fujita, Akari
    Kasaragod, Deepa
    Ueno, Yuta
    Hoshi, Sujin
    Kishino, Genichiro
    Beheregaray, Simone
    Yasuno, Yoshiaki
    Oshika, Tetsuro
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (14) : 5919 - 5925
  • [6] Evaluation of Bleb Birefringence after Glaucoma Surgery using Anterior Segment Polarization-Sensitive Optical Coherence Tomography
    Fukuda, Shinichi
    Beheregaray, Simone
    Kasaragod, Deepa
    Ishii, Kotaro
    Yasuno, Yoshiaki
    Oshika, Tetsuro
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [7] Evaluation of fibrosis in filtering bleb before and after needling revision using polarization-sensitive optical coherence tomography: two case reports.
    Tasaki, Kuniharu
    Ueno, Yuta
    Kasaragod, Deepa
    Hoshi, Sujin
    Fujita, Akari
    Okubo, Tomotaka
    Fukuda, Shinichi
    Yasuno, Yoshiaki
    Oshika, Tetsuro
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [8] Endoscopic polarization-sensitive optical coherence tomography
    Pierce, Mark C.
    Shishkov, Milen
    Park, B. Hyle
    Nassif, Nader
    Bouma, Brett E.
    Tearney, Guillermo J.
    de Boer, Johannes F.
    [J]. COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE X, 2006, 6079
  • [9] Polarization-sensitive interleaved optical coherence tomography
    Duan, Lian
    Marvdashti, Tahereh
    Ellerbee, Audrey K.
    [J]. OPTICS EXPRESS, 2015, 23 (10): : 13693 - 13703
  • [10] Fiber-based polarization-sensitive optical coherence tomography
    Saxer, CE
    de Boer, JF
    Park, BH
    Zhao, YH
    Chen, YP
    Nelson, JS
    [J]. COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICAL SCIENCE AND CLINICAL APPLICATIONS IV, 2000, 3915 : 68 - 75