Evaluation of the performance of titanium and zirconium salts as coagulants in industrial wastewater treatment: pollutant removal, sludge production, and sludge characteristics

被引:17
|
作者
Uysal, Ayla [1 ]
Boyacioglu, Eda [1 ]
机构
[1] Suleyman Demirel Univ, Dept Environm Engn, TR-32260 Isparta, Turkey
关键词
Coagulation; Industrial wastewater treatment; Residual sludge; Sludge volume index; Titanium salt; Zirconium salt; SULFATE FLOCCULATION; TETRACHLORIDE; PRETREATMENT;
D O I
10.1007/s13201-021-01409-1
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
In this study, titanium tetrachloride (TiCl4), zirconium tetrachloride (ZrCl4), and zirconium oxychloride (ZrOCl2 center dot 8H(2)O) were evaluated using jar test experiments as coagulants and compared with traditional aluminum sulfate (Al-2(SO4)(3)center dot 18H(2)O) and ferric chloride (FeCl3) for industrial wastewater treatment. The effects of the initial pH of 4-10 and initial coagulant doses of 10-100 mg/L on chemical oxygen demand (COD) and total suspended solids (TSS) removal were investigated. The performances of the five coagulants were also assessed in terms of the settled sludge volume, the sludge volume index (SVI), and removal efficiencies of metals, color, and total phosphorus (TP) under optimum conditions. In addition, the contents of the residual sludge produced for all five tested coagulants under optimum conditions were determined. The results showed that the maximum removal efficiency of COD (69.33%) was achieved using 100 mg/L TiCl4 at pH 8. The maximum removal efficiency of TSS (98.32%) was achieved using 50 mg/L Al-2(SO4)(3)center dot 18H(2)O at both pH 8 and 10. The settled sludge volume and SVI generated by TiCl4 were lower than that for the other four tested coagulants. ZrCl4, ZrOCl2 center dot 8H(2)O, FeCl3, and Al-2(SO4)(3)center dot 18H(2)O resulted in 128.13, 92.39, 72.26, and 69.66 mL/g SVI, while that using TiCl4 was 48.84 mL/g. Ti- and Zr-based coagulants achieved better removal efficiencies of TP, Zn, and Cu than FeCl3 and Al(SO4)(3)center dot 18H(2)O. The residual sludge from using Ti and Zr coagulants had a very high TP content. The results indicated that Ti- and Zr-based coagulants could be used as alternatives to traditional coagulants for industrial wastewater treatment.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Evaluation of the performance of titanium and zirconium salts as coagulants in industrial wastewater treatment: pollutant removal, sludge production, and sludge characteristics
    Ayla Uysal
    Eda Boyacioglu
    Applied Water Science, 2021, 11
  • [2] Removal of nitrates from industrial wastewater by sewage treatment sludge
    Erbanova, E.
    Palarcik, J.
    Slezak, M.
    Mikulasek, P.
    PROCEEDINGS OF THE 1ST INTERNATIONAL CONFERENCE ON CHEMICAL TECHNOLOGY, 2013, : 301 - 306
  • [3] Evaluation of chemical sludge production in wastewater treatment processes
    Guimaraes, Natalia Rodrigues
    Ferreira Filho, Sidney Seckler
    Hespanhol, Bruno Piotto
    Piveli, Roque Passos
    DESALINATION AND WATER TREATMENT, 2016, 57 (35) : 16346 - 16352
  • [4] Evaluation of municipal and industrial wastewater treatment sludge stabilization in Istanbul
    Pehlivanoglu-Mantas, Elif
    Tas, Didem Okutman
    Insel, Guclu
    Aydin, Egemen
    Ozturk, Duygu C.
    Mez, Tugba
    Gorgun, Erdem
    Cokgorl, Emine Ubay
    Orhon, Derin
    CLEAN-SOIL AIR WATER, 2007, 35 (06) : 558 - 564
  • [5] Production and Effective Utilization of Carbonized Sludge of Industrial Wastewater Treatment Plant
    Kim, Young-Ju
    Choi, Jung-Hoon
    Kim, Ji-Hoon
    Lee, Chang-Soo
    Qureshi, Tahir Imran
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 2010, 32 (01): : 7 - 12
  • [6] Regeneration of Ti Coagulants from Water Treatment Sludge Using acid Leaching: Efficiency in Turbidity and Pollutant Removal
    Bu, Shiyao
    Xu, Xia
    Guo, Jun
    Su, Xiaozan
    Zhang, Shenjie
    Jiang, Chao
    Yang, Yongqiang
    Ni, Tengya
    WATER AIR AND SOIL POLLUTION, 2024, 235 (11):
  • [7] Production and performance of tiles made from wastewater treatment sludge
    College of Civil Engineering, Hunan University, Changsha 410082, China
    Kuei Suan Jen Hsueh Pao, 2007, 2 (251-254): : 251 - 254
  • [8] Acidified and ultrafiltered recovered coagulants from water treatment works sludge for removal of phosphorus from wastewater
    Keeley, James
    Smith, Andrea D.
    Judd, Simon J.
    Jarvis, Peter
    WATER RESEARCH, 2016, 88 : 380 - 388
  • [9] Electrokinetic removal of aluminum and chromium from industrial wastewater electrocoagulation treatment sludge
    Cherifi, Mouna
    Hazourli, Sabir
    Pontvianne, Steeve
    Lapicque, Francois
    Leclerc, Jean-Pierre
    DESALINATION AND WATER TREATMENT, 2016, 57 (39) : 18500 - 18515
  • [10] Performance and evaluation of aerobic granular sludge in oily wastewater treatment
    Wang, S.
    Yang, Q. Q.
    Shi, W. X.
    Yu, S. L.
    Lv, J. Z.
    Li, J.