MR coronary angiography with SH L 643 A: Initial experience in patients with coronary artery disease

被引:23
|
作者
Herborn, CU
Schmidt, M
Bruder, O
Nagel, E
Shamsi, K
Barkhausen, J
机构
[1] Univ Hosp Essen, Dept Diagnost & Intervent Radiol, D-45122 Essen, Germany
[2] Siemens Med Solut, Erlangen, Germany
[3] Elisabeth Hosp, Dept Cardiol, Essen, Germany
[4] German Heart Inst, Dept Cardiol, Berlin, Germany
[5] Berlex, Montville, NJ USA
关键词
arteries; stenosis or obstruction; coronary vessels; MR; magnetic resonance (MR); contrast media; vascular studies;
D O I
10.1148/radiol.2332031545
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To prospectively assess the accuracy of breath-hold three-dimensional magnetic resonance (MR) coronary angiography with the gadolinium-based intra-vascular contrast agent SH L 643 A in patients with coronary artery disease. MATERIALS AND METHODS: Twelve patients (seven men, five women; age range, 46-78 years; mean age, 61.3 years) with angiographically proved coronary artery disease (luminal narrowing >50%) underwent breath-hold three-dimensional MR coronary angiography before and after injection of SH L 643 A (0.1 mmol gadolinium per kilogram body weight). For all MR examinations, signal-to-noise ratio and contrast-to-noise ratio were measured. Image quality was assessed with a four-point scale. Conventional angiograms and MR angiograms were evaluated for depiction of the left main, proximal and middle left anterior descending, proximal left circumflex, and proximal and middle right coronary artery segments in a blinded fashion by two experienced readers in consensus. Results of this evaluation were compared by using a paired Student t test. P <.05 was considered to indicate a statistically significant difference. RESULTS: For the 72 coronary artery segments, the contrast-to-noise ratio significantly improved after administration of SH L 643 A, compared with the prior ratio (9.8 +/- 5.1 [standard deviation] vs 23.0 +/- 8.7; P <.01), whereas the difference in signal-to-noise ratio did not reach statistical significance (25.2 +/- 11.4 vs 29.5 +/- 9.8; P >.3). Image quality significantly improved from a mean of 2.0 +/- 0.9 for nonenhanced images to 2.9 +/- 0.9 (P <.03) for contrast material-enhanced images. The proportion of segments for which images were nondiagnostic decreased from 38% to 10% with application of SH L 643 A. Overall sensitivity and specificity of contrast-enhanced MR coronary angiography for detection of coronary artery disease were 80% and 93%, respectively, and accuracy was 87%. CONCLUSION: Use of SH L 643 A improves detection of coronary artery disease at three-dimensional MR coronary angiography. (C) RSNA, 2004.
引用
收藏
页码:567 / 573
页数:7
相关论文
共 50 条
  • [1] Characterizing coronary motion and its effect on MR coronary angiography - Initial experience
    Al-Kwifi, Osama
    Stainsby, Jeffrey
    Foltz, Warren D.
    Sussman, Marshall S.
    Huang, Yuexi
    Wright, Graham A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (04) : 842 - 850
  • [2] Coronary arteries: Contrast-enhanced MR imaging with SH L 643A - Experience in 12 volunteers
    Herborn, CU
    Barkhausen, J
    Paetsch, I
    Hunold, P
    Mahler, M
    Shamsi, K
    Nagel, E
    RADIOLOGY, 2003, 229 (01) : 217 - 223
  • [3] Coronary MR angiography at 3.0 T versus that at 1.5 T:: Initial results in patients suspected of having coronary artery disease
    Sommer, T
    Hackenbroch, M
    Hofer, U
    Schmiedel, A
    Willinek, WA
    Flacke, S
    Gieseke, J
    Träber, F
    Fimmers, R
    Litt, H
    Schild, H
    RADIOLOGY, 2005, 234 (03) : 718 - 725
  • [4] Postcontrast Whole- Heart Coronary MR Angiography: Initial Experience in Patients
    Piccini, Davide
    Monney, Pierre
    Sierro, Christophe
    Coppo, Simone
    Bonanno, Gabriele
    van Heeswijk, Ruud B.
    Chaptinel, Jerome
    Vincenti, Gabriella
    de Blois, Jonathan
    Koestner, Simon C.
    Rutz, Tobias
    Littmann, Arne
    Zenge, Michael O.
    Schwitter, Juerg
    Stuber, Matthias
    RADIOLOGY, 2014, 270 (02) : 378 - 386
  • [5] Effectiveness of dual-source CT coronary angiography for the evaluation of coronary artery disease in patients with atrial fibrillation: Initial experience
    Oncel, Dilek
    Oncel, Guray
    Tastan, Ahmet
    RADIOLOGY, 2007, 245 (03) : 703 - 711
  • [6] Diagnostic Performance of Ultra-high-resolution CT Coronary Angiography in Patients With Severe Coronary Artery Disease: Initial Experience
    Latina, Jacqueline M.
    Shabani, Mahsima
    Kapoor, Karan
    Sesso, Jaclyn
    Trost, Jeffrey
    Demehri, Shadpour
    Mahesh, Mahadevappa
    Lima, Joao A. C.
    Zadeh, Armin
    CIRCULATION, 2020, 142
  • [7] Applying Nitroglycerin at Coronary MR Angiography at 1.5 T: Diagnostic Performance of Coronary Vasodilation in Patients with Coronary Artery Disease
    Zhao, Shi-hai
    Li, Chen-guang
    Chen, Yin-yin
    Yun, Hong
    Zeng, Meng-su
    Jin, Hang
    RADIOLOGY-CARDIOTHORACIC IMAGING, 2020, 2 (02):
  • [8] Prognostic Value of Whole-Heart Coronary MR Angiography in Patients with Suspected Coronary Artery Disease
    Yoon, Yeonyee E.
    Kitagawa, Kakuya
    Kato, Shingo
    Nagata, Motonori
    Ishida, Masaki
    Nakajima, Hiroshi
    Kurita, Tairo
    Ito, Masaaki
    Sakuma, Hajime
    CIRCULATION, 2011, 124 (21)
  • [9] Comparison of two-dimensional breath-hold coronary MR angiography, three-dimensional coronary MR angiography in navigator technique, and conventional coronary angiography in patients with coronary artery disease
    Lentschig, MG
    Hoeffgen, M
    Wichter, T
    Reimer, P
    Rummeny, EJ
    RADIOLOGY, 1998, 209P : 305 - 305
  • [10] Coronary CT angiography for patients with suspected coronary artery disease
    Rossi, A.
    Dharampal, A.
    de Feyter, P. J.
    HEART, 2014, 100 (12) : 976 - 984