Interaction of helically wound fibre-optic cables with plane seismic waves

被引:114
|
作者
Kuvshinov, B. N. [1 ]
机构
[1] Shell Global Solut Int BV, POB 60, NL-2280 AB Rijswijk, Netherlands
关键词
Acquisition; Mathematical formulation; Seismics; PRESSURE SENSITIVITY; REFLECTIVITY METHOD; ACOUSTIC SENSORS;
D O I
10.1111/1365-2478.12303
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Distributed acoustic sensing is a novel technology for seismic acquisition. In this technology, strain changes induced by seismic waves impinging on an optical fibre are monitored. Due to the fact that glass is relatively rigid, straight glass fibres are not sensitive to broadside waves. We suggest using distributed acoustic sensing systems with fibres helically wound around cables. One increases the fibre sensitivity to broadside waves by decreasing the fibre wrapping angle (the angle between the fibre axis and the plane normal to the cable axis). The optimal wrapping angle is chosen to minimize the impact of Rayleigh waves on the signal measured. This angle depends on the cable Poisson ratio, and it is approximately equal to 30 degrees for cables composed of plastic. For reliable detection of seismic waves, one needs a good mechanical contact between the cable and the surrounding medium. On the other hand, the sensitivity of distributed acoustic sensing systems to primary waves can be significantly reduced if the cable is placed in a cemented borehole.
引用
收藏
页码:671 / 688
页数:18
相关论文
共 36 条