Combustion characteristics of a 16 step grate-firing wood pellet boiler

被引:13
|
作者
Ahn, Joon [1 ]
Jang, Jun Hwan [2 ]
机构
[1] Kookmin Univ, Sch Mech Syst Engn, Seoul 136702, South Korea
[2] Korea Inst Energy Res, Daejeon 305343, South Korea
关键词
Wood pellet; Boiler; Combustion; Heat transfer; RENEWABLE ENERGY-SOURCES; BIOMASS COMBUSTION; HEAT; FUEL;
D O I
10.1016/j.renene.2017.06.015
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A prototype of a 230 kW-class wood pellet boiler employing a four-step grate, was manufactured and tested. The flame extended from the grate to the exit of the combustion chamber, and the combustion efficiency was found to be unsatisfactory. In order to resolve this problem, the number of fire grates was increased to 16, and the combustion chamber was remodeled for performance evaluation. The flame was held on the grate, and as expected, the combustion efficiency improved. However, the last four fire grates were not used even under an operation load condition of 120% of the design capacity, and the size of the combustion chamber increased. To find improvements to this, computational fluid dynamics analysis using a homogeneous model was performed. The simulation results showed that the increase in the aspect ratio of the combustion chamber contributed to complete combustion. However, a recirculation region, not contributing to combustion, was observed at the lower end of the grate. Based on the results of experiments and numerical analysis, a novel furnace design with a lower slope and a smaller number of grates was proposed to reduce the volume of the combustion chamber while still achieving complete combustion. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:678 / 685
页数:8
相关论文
共 49 条