Computational method for bearing surface wear prediction in total hip replacements

被引:13
|
作者
Toh, Shawn Ming Song [1 ]
Ashkanfar, Ariyan [1 ]
English, Russell [1 ]
Rothwell, Glynn [1 ]
机构
[1] Liverpool John Moores Univ, Sch Engn, Byrom St, Liverpool L3 3AF, Merseyside, England
关键词
Wear modelling; Total hip replacement; Hip joint prosthesis; Finite element modelling; Polyethylene wear; TAPER JUNCTION; FRETTING WEAR; JOINT SIMULATOR; YOUNG-PATIENTS; FOLLOW-UP; ARTHROPLASTY; POLYETHYLENE; MODEL; RATES; THICKNESS;
D O I
10.1016/j.jmbbm.2021.104507
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Total hip replacement (THR) is a revolutionary treatment when a hip joint becomes severely damaged. Wear is known as one of the main reasons for THR failure. Current experimental techniques to investigate the wear at the bearing surfaces of THRs are time-consuming, complicated and expensive. In this study, an in-house fretting wear algorithm has been further developed to investigate the wear damage that occurs on bearing surfaces of THRs and its consequence on the longevity of the implants. A 3D finite element model has been created with a 36 mm diameter Cobalt-Chromium femoral head and a 4 mm thick cross-linked polyethylene bearing liner. A gait loading cycle was used to simulate walking for up to 5 million cycles (Mc). The wear algorithm extracts relative displacements and contact shear stresses from the finite element package to predict the linear and volumetric wear rates. This method is shown to have modelled the evolution of wear effectively and found it to be similar to those from experimental analyses. The linear and volumetric wear per million cycles predicted in this study were 0.0375mm/Mc and 33.6mm3/Mc which are comparable to those measured in-vivo THRs. The wear patterns obtained from this study are also comparable to the wear patterns shown on available conventional polyethylene liners. This method can be used to further aid in the design and clinical technique to reduce wear rate in THRs.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Quantifying the bearing surface wear of retrieved hip replacements
    Bergiers, Sean
    Hothi, Harry
    Richards, Robin
    Henckel, Johann
    Hart, Alister
    [J]. Biosurface and Biotribology, 2019, 5 (01): : 28 - 33
  • [2] Dynamic computational wear model of PEEK-on-XLPE bearing couple in total hip replacements
    Alpkaya, Alican Tuncay
    Mihcin, Senay
    [J]. MEDICAL ENGINEERING & PHYSICS, 2023, 117
  • [3] Computational modelling of polyethylene wear and creep in total hip joint replacements: Effect of the bearing clearance and diameter
    Liu, Feng
    Fisher, John
    Jin, Zhongmin
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART J-JOURNAL OF ENGINEERING TRIBOLOGY, 2012, 226 (J6) : 552 - 563
  • [4] Computational model of asperity contact for the prediction of UHMWPE mechanical and wear behaviour in total hip joint replacements
    Suhendra, N.
    Stachowiak, G. W.
    [J]. TRIBOLOGY LETTERS, 2007, 25 (01) : 8 - 22
  • [5] Computational model of asperity contact for the prediction of UHMWPE mechanical and wear behaviour in total hip joint replacements
    N. Suhendra
    G.W. Stachowiak
    [J]. Tribology Letters, 2007, 25 : 9 - 22
  • [6] A computational approach to fretting wear prediction at the head-stem taper junction of total hip replacements
    English, Russell
    Ashkanfar, Ariyan
    Rothwell, Glynn
    [J]. WEAR, 2015, 338 : 210 - 220
  • [7] Wear in total hip and knee replacements
    Paling, IH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (12): : 1806 - 1806
  • [8] Wear in total hip and knee replacements
    Schmalzried, TP
    Callaghan, JJ
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (01): : 115 - 136
  • [9] Computational wear prediction of UHMWPE in knee replacements
    Zhao, Dong
    Sawyer, W. Gregory
    Fregly, Benjamin J.
    [J]. WEAR OF ARTICULATING SURFACES: UNDERSTANDING JOINT SIMULATION, 2006, 1472 : 45 - +
  • [10] WEAR AND CORROSION OF MODULAR INTERFACES IN TOTAL HIP REPLACEMENTS
    COOK, SD
    BARRACK, RL
    BAFFES, GC
    CLEMOW, AJT
    SEREKIAN, P
    DONG, N
    KESTER, MA
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1994, (298) : 80 - 88