Heat transfer performance of the underground CO2 pipe in the direct expansion ground source heat pump

被引:9
|
作者
Gao, Yuefen [1 ]
Cheng, Yongzhao [1 ]
Nan, Shanshan [1 ]
机构
[1] North China Elect Power Univ, 619 Yonghua North St, Baoding 071003, Peoples R China
关键词
CO2 direct expansion ground source heat pump; underground heat exchanger; gas cooler; heat transfer performance;
D O I
10.1016/j.egypro.2017.03.989
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Under the refrigerating condition, the pipe circulating CO2 is directly buried underground. It acts as the gas cooler releasing heat from the refrigerant to the soil directly. The heat transfer performance of the CO2 gas cooler is very important to the performance of the direct expansion ground source heat pump. The heat transfer process at the gas cooler is analyzed. Based on that, the mathematic model of the buried pipe is established using energy balance method. Then the influence factors including shank spacing, thermal conductivity of soil and backfill material, inlet temperature and mass flow rate of refrigerant are studied. The results show that the heat transfer performance of the underground CO2 pipe has a tendency to increase with the factors. The results also show that thermal short circuiting exists between the shanks of CO2 gas cooler. (C) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:4955 / 4962
页数:8
相关论文
共 50 条
  • [1] Influence of an internal heat exchanger on the operation of a CO2 direct expansion ground source heat pump
    Nguyen, A.
    Eslami-Nejad, P.
    Badache, M.
    Bastani, A.
    [J]. ENERGY AND BUILDINGS, 2019, 202
  • [2] Study on the heat transfer performance of boiling in vertical buried tube of direct expansion ground source heat pump
    Gao, Yuefen
    Gao, Tingling
    Liu, Zhao
    [J]. INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 5494 - 5503
  • [3] Experimental characterization of a transcritical CO2 direct expansion ground source heat pump for heating applications
    Bastani, Arash
    Eslami-Nejad, Parham
    Badache, Messaoud
    Alain Tuan Anh Nguyen
    [J]. ENERGY AND BUILDINGS, 2020, 212 (212)
  • [4] Performance study of heat pipe heat exchanger for ground source heat pump
    Hsieh, Jui Ching
    Lin, David T.W.
    Shin, Long Der
    [J]. 1600, Chinese Mechanical Engineering Society (35): : 165 - 170
  • [5] Detailed Theoretical Characterization of a Transcritical CO2 Direct Expansion Ground Source Heat Pump Water Heater
    Eslami-Nejad, Parham
    Badache, Messaoud
    Bastani, Arash
    Aidoun, Zine
    [J]. ENERGIES, 2018, 11 (02)
  • [6] Performance of a direct expansion ground-source heat pump for air conditioning
    Moriya, Dai
    Takeda, Tetsuaki
    [J]. Proceedings of the International Conference on Power Engineering 2021, ICOPE 2021, 2021,
  • [7] INFLUENCE FACTORS ANALYSIS ON HEAT TRANSFER PERFORMANCE OF UNDERGROUND HEAT EXCHANGER IN GROUND-SOURCE HEAT PUMP SYSTEM
    Wu, X. Y.
    Dai, X. L.
    Yang, J. C.
    [J]. 7TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, PROCEEDINGS OF ISHVAC 2011, VOLS I-IV, 2011, : 811 - 817
  • [8] The application of thermoelectric and ejector in a CO2 direct-expansion ground source heat pump; energy and exergy analysis
    Ghazizade-Ahsaee, Hossein
    Askari, Ighball Baniasad
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2020, 226
  • [9] STUDIES ON THE PERFORMANCE AND HEAT TRANSFER OF CO2 HEAT PUMP SYSTEM
    Lee, Jae Seung
    Kim, Min Soo
    [J]. ACRA 2009: PROCEEDINGS OF THE 4TH ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, 2009, : 1 - 6
  • [10] Heat transfer performance test and numerical simulation of pile-pipe ground source heat pump system
    Institute of HVAC and GAS Engineering, Tongji University, Shanghai 200092, China
    [J]. Taiyangneng Xuebao, 2009, 6 (727-731):