Anatomic three-dimensional echocardiographic correlation of bicuspid aortic valve

被引:25
|
作者
Espinola-Zavaleta, N [1 ]
Muñoz-Castellanos, L [1 ]
Attié, F [1 ]
Hernández-Morales, G [1 ]
Zamora-González, C [1 ]
Dueñas-Carbajal, R [1 ]
Granados, N [1 ]
Keirns, C [1 ]
Vargas-Barrón, J [1 ]
机构
[1] Inst Nacl Cardiol Ignacio Chavez, Dept Echocardiog, Mexico City 14080, DF, Mexico
关键词
D O I
10.1067/mje.2003.30
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study was undertaken to verify the echocardiographic characteristics of bicuspid aortic valve (AV) using 3-dimensional transesophageal echocardiography by comparing the findings with anatomic examination of autopsy specimens from carriers of this condition. Three-dimensional reconstructions of transesophageal echocardiograms were performed on 14 patients with bicuspid AV, and 20 autopsy specimens of bicuspid AVs were analyzed. Echocardiographic images and autopsy material were correlated. Two variants of bicuspid aorta were identified. in group I the AV had 2 leaflets. This group included 9 (9/14) 3-dimensional echocardiographic studies and 13 (13/20) necropsies. In group H 3 sigmoid leaflets had originally developed and 2 underwent dysplastic fusion, resulting in functionally bicuspid valves. Five (5/14) echocardiographic studies and 7 (7/20) anatomic specimens fell into this category. There was a clear correspondence between anatomic and echocardiographic firidings, which leads to the conclusion that 3-dimensional echocardiography is a technique that reliably defines the morphological details of bicuspid AV with the precision of anatomopathologic examination.
引用
收藏
页码:46 / 53
页数:8
相关论文
共 50 条
  • [1] Quantitative three-dimensional echocardiographic analysis of the bicuspid aortic valve and aortic root: A single modality approach
    Levack, Melissa M.
    Mecozzi, Gianclaudio
    Jainandunsing, Jayant S.
    Bouma, Wobbe
    Jassar, Arminder S.
    Pouch, Alison M.
    Yushkevich, Paul A.
    Mariani, Massimo A.
    Jackson, Benjamin M.
    Gorman, Joseph H., III
    Gorman, Robert C.
    [J]. JOURNAL OF CARDIAC SURGERY, 2020, 35 (02) : 375 - 382
  • [2] Live/Real Time Three-Dimensional Transthoracic Echocardiographic Assessment of Bicuspid Aortic Valve Morphology
    Singh, Preeti
    Dutta, Rajarshi
    Nanda, Navin C.
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2009, 26 (04): : 478 - 480
  • [3] Double Orifice Mitral Valve with Bicuspid Aortic Valve in Real Time Three-Dimensional Transesophageal Echocardiographic Examination
    Lee, Ga Yeon
    Chang, Sung-A
    Park, Seung Woo
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2012, 29 (09): : E253 - E254
  • [4] ACCURACY OF TWO-DIMENSIONAL ECHOCARDIOGRAPHIC DIAGNOSIS OF CONGENITALLY BICUSPID AORTIC-VALVE - ECHOCARDIOGRAPHIC-ANATOMIC CORRELATION IN 115 PATIENTS
    BRANDENBURG, RO
    TAJIK, AJ
    EDWARDS, WD
    REEDER, GS
    SHUB, C
    SEWARD, JB
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1983, 51 (09): : 1469 - 1473
  • [5] Assessment of valvular surfaces in children with a congenital bicuspid aortic valve: Preliminary three-dimensional echocardiographic study
    Cognet, Thomas
    Seguela, Pierre-Emmanuel
    Thomson, Emilie
    Bouisset, Frederic
    Lairez, Olivier
    Hascoet, Sebastien
    Carrie, Didier
    Acar, Philippe
    [J]. ARCHIVES OF CARDIOVASCULAR DISEASES, 2013, 106 (05) : 295 - 302
  • [6] Three-dimensional echocardiographic assessment of the aortic valve and the aorta
    Smer, Aiman
    Urja, Prakrity
    Anugula, Dixitha
    Dulal, Subash
    Elmarzouky, Zeyad M.
    Gill, Edward
    Nanda, Navin C.
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2022, 39 (07): : 1011 - 1027
  • [7] Three-Dimensional Echocardiographic Evaluation of a Patient with Double-Orifice Mitral Valve, Bicuspid Aortic Valve, and Coarctation of Aorta
    Kocabas, Abdullah
    Ekici, Filiz
    Cetin, Ilker
    Aktas, Dogukan
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2014, 31 (01): : E33 - E34
  • [8] Three-dimensional echocardiography diagnosis of double perforation of bicuspid aortic valve
    Longobardo, Luca
    Coluccia, Valentina
    Azzu, Alessia
    Scarfo, Iside S.
    Alfieri, Ottavio
    La Canna, Giovanni
    [J]. JOURNAL OF CARDIOVASCULAR MEDICINE, 2017, 18 (10) : 841 - 842
  • [9] Three-dimensional echocardiographic evaluation of aortic and mitral valve stenosis
    Mohr-Kahaly, S
    Menzel, T
    Kupferwasser, I
    Schlosser, A
    Von Bardeleben, S
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1999, 16 (07): : 723 - 730
  • [10] Double Orifice Mitral Valve With Bicuspid Aortic Valve Evaluation by Three-Dimensional Echocardiography
    Kharwar, Rajiv Bharat
    Sharma, Akhil
    Sethi, Rishi
    Narain, Varun Shankar
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (01) : e1