Silent hemoglobin variants and determination of HbA1c with the high-resolution program of the HPLC HA-8160 hemoglobin analyzer

被引:50
|
作者
Schnedl, WJ
Lahousen, T
Wallner, SJ
Krause, R
Lipp, RW
机构
[1] Med Univ Graz, Dept Internal Med, A-8036 Graz, Austria
[2] Med Univ Graz, Dept Psychiat, A-8036 Graz, Austria
关键词
diabetes mellitus; glycated hemoglobin; HbA(1c); hemoglobin variants; ion-exchange HPLC;
D O I
10.1016/j.clinbiochem.2004.09.016
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: Evaluation of HbA(1c) determination with an automated ion-exchange high-performance liquid chromatography (HPLC) method in patients with clinically silent hemoglobin (Hb) variants. Design and methods: HbA(1c) values were determined with the Arkray HA-8160 ion-exchange HPLC Using the high-resolution, 4.2-min beta-thalassemia screening mode in patients with silent hemoglobin (Hb) variants, namely, Hb Graz, Hb Sherwood Forest, Hb 0 Padova, and HbD. Results: All of these hemoglobin variants caused additional peaks in the chromatograms, without HbA(1c) results in patients with Hb Graz and Hb Sherwood Forest, and demonstrated extra peaks with HbA(1c) results that were clinically too tow for patients with Hb O Padova and in the patient with HbD. Conclusions: The development of this automated HPLC method modification with high-resolution beta-thalassemia screening mode aids identification of interference due to some clinically silent Fib variants in HbA(1c) determination. (C) 2004 The Canadian Society of Clinical Chemists. All rights reserved.
引用
收藏
页码:88 / 91
页数:4
相关论文
共 50 条
  • [1] Effect of hemoglobin Porto Alegre on glycated hemoglobin (HbA1c) measurement with the HA-8160 high performance liquid chromatography method
    Lorenzo-Medina, Mercedes
    De-La-Iglesia, Silvia
    Ropero, Paloma
    Martin-Aguila, Adys
    Ruiz-Garcia, Lidia
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2013, 51 (10) : E247 - E249
  • [2] Interference of hemoglobin (Hb) N-Baltimore on measurement of HbA1c using the HA-8160 HPLC method
    Lorenzo-Medina, Mercedes
    De-La-Iglesia, Silvia
    Ropero, Paloma
    Nogueira-Salgueiro, Patricia
    Martin-Aguila, Adys
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2013, 51 (02) : E13 - E15
  • [3] INFLUENCE OF HEMOGLOBIN F AND THE VARIANTS OF HEMOGLOBIN IN THE DETERMINATION OF HBA1C BY HPLC AND EIA
    Payan Pernia, S.
    Canyelles Vich, M.
    Serra Ferrer, M.
    Cerda Gordillo, N.
    Guerrero Lopez, L.
    Remacha Sevilla, A.
    HAEMATOLOGICA, 2017, 102 : 152 - 153
  • [4] Hemoglobin variants and determination of glycated hemoglobin (HbA1C)
    Schnedl, WJ
    Liebminger, A
    Roller, RE
    Lipp, RW
    Krejs, GJ
    DIABETES-METABOLISM RESEARCH AND REVIEWS, 2001, 17 (02) : 94 - 98
  • [5] The effects of hemoglobin variants on measurements of HbA1C by HPLC
    Seydel, G. S.
    Guzelgul, F.
    Yalin, E.
    Sonmez, E.
    Aksoy, K.
    FEBS JOURNAL, 2016, 283 : 366 - 366
  • [6] Hemoglobin variants detected by hemoglobin A1c (HbA1c) analysis and the effects on HbA1c measurements
    Nasir, Nadzimah Mohd
    Thevarajah, M.
    Yean, Chew Yee
    INTERNATIONAL JOURNAL OF DIABETES IN DEVELOPING COUNTRIES, 2010, 30 (02) : 86 - 90
  • [7] On the determination of glycated hemoglobin (HbA1c)
    Lahousen, T
    Roller, RE
    Lipp, RW
    Schnedl, NJ
    WIENER KLINISCHE WOCHENSCHRIFT, 2002, 114 (8-9) : 301 - 305
  • [8] Analytical performance evaluation of hemoglobin A1c on an ARKRAY HA-8160 analyzer with newly-developed mobile phase buffer
    Yu, Yuan
    Zhang, Xiaoyun
    Lin, Kai
    PRACTICAL LABORATORY MEDICINE, 2024, 40
  • [9] Interference of hemoglobin variants in HbA1c quantification
    Yadav, Neha
    Mandal, Amit Kumar
    CLINICA CHIMICA ACTA, 2023, 539 : 55 - 65
  • [10] Evaluation on the separated effect of 13 hemoglobin variants by a new automatic Hba1c analyzer
    Li, Rui
    Tang, Huamei
    Kan, Lijuan
    Xiong, Dan
    Cheng, Xuedi
    Xu, Yan
    Liu, Xiancheng
    Zhang, Xiuming
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2020, 34 (10)