Biomechanical, scanning electron microscopy, and microhardness analyses of the bone-pin interface in hydroxyapatite coated versus uncoated pins

被引:38
|
作者
Moroni, A [1 ]
Caja, VL [1 ]
Maltarello, MC [1 ]
Savarino, L [1 ]
Marinelli, F [1 ]
Stea, S [1 ]
Visentin, M [1 ]
Giannini, S [1 ]
机构
[1] Univ Bologna, Rizzoli Orthopaed Inst, Dept Orthopaed Surg 9, I-40136 Bologna, Italy
关键词
external fixation; hydroxyapatite; interface; pin;
D O I
10.1097/00005131-199704000-00003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To evaluate the bone-pin interface in hydroxyapatite coated versus uncoated pins. Design: Eighty-four bicylindrical stainless steel external fixation pins were implanted in a test group of 14 sheep. One-half of the pins were coated with hydroxyapatite and the rest remained uncoated. Intervention: Six coated pins were implanted in the left tibia of seven sheep, and six uncoated pins were implanted in the left tibia of the other seven sheep. In all sheep, the right tibia was left intact. During pin implantation, the final insertion torque was measured, and a linear external fixator was mounted on the pins. Then the medial tibial mid-diaphysis was exposed and a 5-mm resection osteotomy was performed. The sheep were killed six weeks after surgery. Main Outcome Measures: The extraction torque was measured on four pins removed from each sheep. Radiographic pin tract rarefaction was measured on all the pins. Two pins from each sheep were used for histologic, scanning electron microscopy (SEM), and microhardness analysis. Histomorphometric analysis was carried out on the SEM specimens at x 36 magnification. Results: Radiographic pin tract rarefaction was significantly lower in the hydroxyapatite coated pins than in the uncoated pins (p < 0.001). Group average insertion torque was 960 +/- 959 N/mm in the hydroxyapatite coated pins, and 709 +/- 585 N/mm in the uncoated pins (p = not significant). Group average extraction torque was 1485 +/- 1308 N/mm and 298 +/- 373 N/mm, respectively (p = 0.0001). Histomorphometric analysis showed that the group average bone-pin contact was 50.7 +/- 16.9% in the hydroxyapatite coated pins and 27.6 +/- 7.1% in the uncoated pins (p < 0.01). Microhardness analysis showed that bone tissue close to the pins was softer than bone tissue far from them. Conclusion: Hydroxyapatite coating is an effective method of refining the bone-pin interface and may improve the clinical results of the external fixation technique.
引用
收藏
页码:154 / 161
页数:8
相关论文
共 9 条
  • [1] BONE INGROWTH ANALYSIS AND INTERFACE EVALUATION OF HYDROXYAPATITE-COATED VERSUS UNCOATED TITANIUM POROUS BONE IMPLANTS
    MORONI, A
    CAJA, VL
    SABATO, C
    EGGER, EL
    GOTTSAUNERWOLF, F
    CHAO, EYS
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1994, 5 (6-7) : 411 - 416
  • [2] X-ray diffraction of bone at the interface with hydroxyapatite-coated versus uncoated metal implants
    Savarino, L
    Stea, S
    Granchi, D
    Donati, ME
    Cervellati, M
    Moroni, A
    Paganetto, G
    Pizzoferrato, A
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1998, 9 (02) : 109 - 115
  • [3] X-ray diffraction of bone at the interface with hydroxyapatite-coated versus uncoated metal implants
    L SAVARINO
    S STEA
    D GRANCHI
    M. E DONATI
    M CERVELLATI
    A MORONI
    G PAGANETTO
    A PIZZOFERRATO
    Journal of Materials Science: Materials in Medicine, 1998, 9 : 109 - 115
  • [4] SCANNING ELECTRON-MICROSCOPY OF THE BONE INTERFACE WITH TITANIUM, TITANIUM-ALLOY AND HYDROXYAPATITE
    ORR, RD
    DEBRUIJN, JD
    DAVIES, JE
    CELLS AND MATERIALS, 1992, 2 (03): : 241 - 251
  • [5] Improvement of the bone-pin interface strength in osteoporotic bone with use of hydroxypatite-coated tapered external-fixation pins - A prospective, randomized clinical study of wrist fractures
    Moroni, A
    Faldini, C
    Marchetti, S
    Manca, M
    Consoli, V
    Giannini, S
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (05): : 717 - 721
  • [6] Histological and scanning electron microscopy analyses of bone/implant interface using the novel bonelikee synthetic bone graft
    Gutierres, M
    Hussain, NS
    Lopes, MA
    Afonso, A
    Cabral, AT
    Almeida, L
    Santos, JD
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2006, 24 (05) : 953 - 958
  • [7] Potential of Titanium Pins Coated with Fibroblast Growth Factor-2-Calcium Phosphate Composite Layers to Reduce the Risk of Impaired Bone-Pin Interface Strength in the External Fixation of Distal Radius Fractures
    Mutsuzaki, Hirotaka
    Yanagisawa, Yohei
    Noguchi, Hiroshi
    Ito, Atsuo
    Yamazaki, Masashi
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (11)
  • [8] A LIGHT AND LASER-SCANNING MICROSCOPY STUDY OF BONE/HYDROXYAPATITE-COATED TITANIUM IMPLANTS INTERFACE - HISTOCHEMICAL EVIDENCE OF UNMINERALIZED MATERIAL IN HUMANS
    PIATTELLI, A
    TRISI, P
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1994, 28 (05): : 529 - 536
  • [9] SCANNING AND TRANSMISSION ELECTRON-MICROSCOPY, AND ELECTRON-PROBE ANALYSIS OF THE INTERFACE BETWEEN IMPLANTS AND HOST BONE - OSSEO-COALESCENCE VERSUS OSSEOINTEGRATION
    DACULSI, G
    LEGEROS, RZ
    DEUDON, C
    SCANNING MICROSCOPY, 1990, 4 (02) : 309 - 314