Liquid hydrogen cold neutron source in operation at the Budapest Research Reactor

被引:4
|
作者
Rosta, L
Grósz, T
Hargitai, T
机构
[1] Res Inst Solid State Phys & Opt, Budapest, Hungary
[2] KFKI Atom Energy Res Inst, Budapest, Hungary
[3] Budapest Neutron Ctr, Budapest, Hungary
来源
关键词
D O I
10.1007/s003390201930
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A cold-neutron source (CNS) was commissioned at the 10-MW Budapest Research Reactor and has been in routine operation since February 2001. A 'direct-cooling' moderator assembly with the proper helium cryogenic system has been installed, and at relatively small cooling power (thus modest costs) enhanced performance and improved safety characteristics have been obtained. The ensemble of the CNS and an upgraded guide system provides an intensity gain factor of 30-60 for five spectrometers at the Budapest Neutron Centre.
引用
收藏
页码:S240 / S242
页数:3
相关论文
共 50 条
  • [1] Liquid hydrogen cold neutron source in operation. at the Budapest Research Reactor
    L. Rosta
    T. Grósz
    T. Hargitai
    [J]. Applied Physics A, 2002, 74 : s240 - s242
  • [2] COLD NEUTRON SOURCE AT THE BUDAPEST REACTOR
    GROSZ, T
    CSER, L
    ROSTA, L
    SZALOK, M
    ZSIGMOND, G
    [J]. PHYSICA B, 1992, 180 : 932 - 934
  • [3] Liquid hydrogen cold moderator optimisation at the Budapest Research Reactor
    Grosz, T
    Mityukhlyaev, VA
    Rosta, L
    Serebrov, AP
    Zaharov, AA
    [J]. PHYSICA B, 1997, 234 : 1194 - 1195
  • [4] Experimental characterization of the Advanced Liquid Hydrogen Cold Neutron Source spectrum of the NBSR reactor at the NIST Center for Neutron Research
    Cook, J. C.
    Barker, J. G.
    Rowe, J. M.
    Williams, R. E.
    Gagnon, C.
    Lindstrom, R. M.
    Ibberson, R. M.
    Neumann, D. A.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 792 : 15 - 27
  • [5] Hydrogen safety in cold neutron source in a reactor
    China Academy of Engineering Physics, Mianyang 621900, China
    [J]. He Jishu, 2008, 2 (157-160):
  • [6] Physics study of liquid hydrogen moderator of CMRR reactor cold neutron source
    Mei, Longwei
    Liu, Cong
    Wang, Songlin
    Shen, Fei
    [J]. PROGRESS IN NUCLEAR ENERGY, 2019, 110 : 121 - 128
  • [7] The cold neutron PGAA-NIPS facility at the Budapest research reactor
    Belgya, T
    Révay, Z
    Ember, PP
    Weil, J
    Molnár, GL
    Qaim, SM
    [J]. CAPTURE GAMMA-RAY SPECTROSCOPY AND RELATED TOPICS, 2003, : 562 - 568
  • [8] The cold neutron source of the Munich Research Reactor (FRM)
    Gerstenberg, H
    Krahling, E
    Pathe, D
    Schreckenbach, K
    Glaser, W
    [J]. ADVANCES IN CRYOGENIC ENGINEERING, VOL 43 PTS A AND B, 1998, 43 : 613 - 620
  • [9] Cold neutron research facility at the Budapest Neutron Centre
    L. Rosta
    [J]. Applied Physics A, 2002, 74 : s52 - s54
  • [10] Cold neutron research facility at the Budapest Neutron Centre