Spectral computed tomography for quantitative decomposition of vulnerable plaques using a dual-energy technique: a Monte Carlo simulation study

被引:3
|
作者
Jo, B. D. [1 ,2 ]
Park, S. -J. [1 ,2 ]
Kim, H. M. [1 ,2 ]
Kim, D. H. [3 ]
Kim, H. -J. [1 ,2 ,3 ]
机构
[1] Yonsei Univ, Dept Radiol Sci, 1 Yonseidae Gil, Wonju 220710, Gangwon, South Korea
[2] Yonsei Univ, Res Inst Hlth Sci, 1 Yonseidae Gil, Wonju 220710, Gangwon, South Korea
[3] Yonsei Univ, Coll Hlth Sci, Dept Radiat Convergence Engn, 1 Yonseidae Gil, Wonju 220710, Gangwon, South Korea
来源
基金
新加坡国家研究基金会;
关键词
X-ray detectors; Pattern recognition; cluster finding; calibration and fitting methods; Gamma camera; SPECT; PET PET/CT; coronary CT angiography (CTA); Computerized Tomography (CT) and Computed Radiography (CR); PHOTON-COUNTING DETECTORS; X-RAY-DETECTORS; NANOPARTICLE CONTRAST; GOLD NANOPARTICLES; CT; MAMMOGRAPHY; MACROPHAGES; DISEASE;
D O I
10.1088/1748-0221/11/02/P02011
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A spectral computed tomography (CT) system based on an energy-resolved photon-counting Cadmium Zinc Telluride (CZT) detector with a dual energy technique can provide spectral information and can possibly distinguish between two or more materials with a single X-ray exposure using energy thresholds. This work provides the potential for three-material decomposition of vulnerable plaques using two inverse fitting functions. Additionally, there exists the possibility of using gold nanoparticles as a contrast agent for the spectral CT system in conjunction with a CZT photon-counting detector. In this simulation study, we used fan beam CT geometry that consisted of a 90 kVp X-ray spectrum and performed calculations by using the SpekCal program (REAL Software, Inc.) with Monte Carlo simulations. A basic test phantom was imaged with the spectral CT system for the calibration and decomposition process. This phantom contained three different materials, including lipid, iodine and gold nanoparticles, with six holes 3 mm in diameter. In addition to reducing pile-up and charge sharing effect, the photon counting detector was considered an ideal detector. Then, the accuracy of material decomposition techniques with two inverse fitting functions were evaluated between decomposed images and reference images in terms of root mean square error (RMSE). The results showed that decomposed images had a good volumetric fraction for each material, and the RMSE between the measured and true volumes of lipid, iodine and gold nanoparticle fractions varied from 12.51% to 1.29% for inverse fitting functions. The study indicated that spectral CT in conjunction with a CZT photon-counting detector in conjunction with a dual energy technique can be used to identifying materials and may be a promising modality for quantifying material properties of vulnerable plaques.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Organ dose in cardiac dual-energy computed tomography: a Monte Carlo study
    Delaram Pakravan
    Farshid Babapour Mofrad
    Mohammad Reza Deevband
    Mahdi Ghorbani
    Hamidreza Pouraliakbar
    [J]. Physical and Engineering Sciences in Medicine, 2022, 45 : 157 - 166
  • [2] Organ dose in cardiac dual-energy computed tomography: a Monte Carlo study
    Pakravan, Delaram
    Mofrad, Farshid Babapour
    Deevband, Mohammad Reza
    Ghorbani, Mahdi
    Pouraliakbar, Hamidreza
    [J]. PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2022, 45 (01) : 157 - 166
  • [3] Presentation of Organ Dose and Effective Dose Conversion Factors in Dual-Energy Computed Tomography: A Monte Carlo Simulation Study
    Pakravan, Delaram
    [J]. Journal of Biomedical Physics and Engineering, 2023, 13 (04): : 333 - 344
  • [4] Evaluation of material decomposition for pulmonary function test in spectral computed tomography: A Monte Carlo simulation study
    Eom, Jisoo
    Kim, Burnyoung
    Kim, Wonhyung
    Lee, Seungwan
    [J]. OPTIK, 2018, 174 : 409 - 415
  • [5] Dual-Energy Computed Tomography Virtual Noncalcium Technique in Diagnosing Osteoporosis: Correlation With Quantitative Computed Tomography
    Liu, Zhenghua
    Zhang, Yuting
    Liu, Zhou
    Kong, Jiangtao
    Huang, Dageng
    Zhang, Xiaoyue
    Jiang, Yonghong
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2021, 45 (03) : 452 - 457
  • [6] A Novel Decomposition Method for Dual-energy Computed Tomography
    Li, Yuanji
    Zhang, Li
    Kang, Kejun
    Chen, Zhiqiang
    [J]. 2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [7] Opportunistic screening for osteoporosis using enhanced images based on dual-energy computed tomography material decomposition: a comparison with quantitative computed tomography
    Tong, Xiaoyu
    Fang, Xin
    Wang, Shigeng
    Fan, Yong
    Wei, Wei
    Xiao, Qingzhu
    Chen, Anliang
    Liu, Yijun
    Liu, Lei
    [J]. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (01) : 352 - 364
  • [8] THE COMPOSITION OF BONE-MARROW FOR A DUAL-ENERGY QUANTITATIVE COMPUTED-TOMOGRAPHY TECHNIQUE - A CADAVER AND COMPUTER-SIMULATION STUDY
    GOODSITT, MM
    HOOVER, P
    VELDEE, MS
    HSUEH, SL
    [J]. INVESTIGATIVE RADIOLOGY, 1994, 29 (07) : 695 - 704
  • [9] Spectral Signal Density of Carotid Plaque Using Dual-Energy Computed Tomography
    Reynoso, Exequiel
    Rodriguez-Granillo, Gaston A.
    Capunay, Carlos
    Deviggiano, Alejandro
    Meli, Francisco
    Carrascosa, Patricia
    [J]. JOURNAL OF NEUROIMAGING, 2017, 27 (05) : 511 - 516
  • [10] Diagnostic Accuracy of Dual-Energy CT Material Decomposition Technique for Assessing Bone Status Compared with Quantitative Computed Tomography
    Wang, Xu
    Li, Beibei
    Tong, Xiaoyu
    Fan, Yong
    Wang, Shigeng
    Liu, Yijun
    Fang, Xin
    Liu, Lei
    [J]. DIAGNOSTICS, 2023, 13 (10)