Current Practices of Measuring and Reference Range Reporting of Free and Total Testosterone in the United States

被引:20
|
作者
Le, Margaret [1 ]
Flores, David [1 ]
May, Danica [1 ]
Gourley, Eric [1 ]
Nangia, Ajay K. [1 ]
机构
[1] Univ Kansas, Med Ctr, Dept Urol, 3901 Rainbow Blvd, Kansas City, KS 66160 USA
来源
JOURNAL OF UROLOGY | 2016年 / 195卷 / 05期
关键词
testis; testosterone; hypogonadism; reference values; laboratories; SERUM TESTOSTERONE; MEN; DIAGNOSIS; DEFICIENCY; ASSAYS;
D O I
10.1016/j.juro.2015.12.070
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: The evaluation and management of male hypogonadism should be based on symptoms and on serum testosterone levels. Diagnostically this relies on accurate testing and reference values. Our objective was to define the distribution of reference values and assays for free and total testosterone by clinical laboratories in the United States. Materials and Methods: Upper and lower reference values, assay methodology and source of published reference ranges were obtained from laboratories across the country. A standardized survey was reviewed with laboratory staff via telephone. Descriptive statistics were used to tabulate results. Results: We surveyed a total of 120 laboratories in 47 states. Total testosterone was measured in house at 73% of laboratories. At the remaining laboratories studies were sent to larger centralized reference facilities. The mean +/- SD lower reference value of total testosterone was 231 +/- 46 ng/dl (range 160 to 300) and the mean upper limit was 850 +/- 141 ng/dl (range 726 to 1,130). Only 9% of laboratories where in-house total testosterone testing was performed created a reference range unique to their region. Others validated the instrument recommended reference values in a small number of internal test samples. For free testosterone 82% of laboratories sent testing to larger centralized reference laboratories where equilibrium dialysis and/or liquid chromatography with mass spectrometry was done. The remaining laboratories used published algorithms to calculate serum free testosterone. Conclusions: Reference ranges for testosterone assays vary significantly among laboratories. The ranges are predominantly defined by limited population studies of men with unknown medical and reproductive histories. These poorly defined and variable reference values, especially the lower limit, affect how clinicians determine treatment.
引用
收藏
页码:1556 / 1561
页数:6
相关论文
共 50 条
  • [1] CURRENT PRACTICES OF MEASURING AND REFERENCE RANGE REPORTING OF FREE AND TOTAL TESTOSTERONE IN THE UNITED STATES
    Le, Margaret
    Flores, David
    Gourley, Eric
    May, Danica
    Nangia, Ajay
    [J]. JOURNAL OF UROLOGY, 2015, 193 (04): : E622 - E622
  • [2] Current Practices of Measuring and Reference Range Reporting of Free and Total Testosterone in the United States EDITORIAL COMMENT
    Koehler, Tobias S.
    [J]. JOURNAL OF UROLOGY, 2016, 195 (05): : 1561 - 1561
  • [3] Melanoma Reporting Practices of United States Dermatologists
    Svoboda, Ryan M.
    Glazer, Alex M.
    Farberg, Aaron S.
    Cowdrey, Molly C. E.
    Rigel, Darrell S.
    [J]. DERMATOLOGIC SURGERY, 2018, 44 (11) : 1391 - 1395
  • [4] Assessment Centers: Current Practices in the United States
    Tasha L. Eurich
    Diana E. Krause
    Konstantin Cigularov
    George C. Thornton
    [J]. Journal of Business and Psychology, 2009, 24 : 387 - 407
  • [5] Assessment Centers: Current Practices in the United States
    Eurich, Tasha L.
    Krause, Diana E.
    Cigularov, Konstantin
    Thornton, George C., III
    [J]. JOURNAL OF BUSINESS AND PSYCHOLOGY, 2009, 24 (04) : 387 - 407
  • [6] Nonpathogenic protozoa: Laboratory reporting practices in Canada and the United States
    Lee, MB
    Keystone, JS
    Kain, KC
    [J]. LABORATORY MEDICINE, 2001, 32 (08) : 455 - 456
  • [7] Accurate Measurement and Harmonized Reference Ranges for Total and Free Testosterone Levels
    Jasuja, Ravi
    Pencina, Karol M.
    Peng, Liming
    Bhasin, Shalender
    [J]. ENDOCRINOLOGY AND METABOLISM CLINICS OF NORTH AMERICA, 2022, 51 (01) : 63 - 75
  • [8] Reference ranges for total testosterone, SHBG, free testosterone and bioavailable testosterone in a young healthy women population.
    Fink, G. D.
    Zannoni, S.
    Desmarais, G.
    Baillargeon, J.
    [J]. CLINICAL CHEMISTRY, 2007, 53 (06) : A189 - A189
  • [9] CURRENT POLLUTION CONTROL PRACTICES IN THE UNITED STATES.
    Boyer, Michael J.
    [J]. 1600, (61):
  • [10] HCC Surveillance: An Inquiry Into Current Practices in the United States
    Joshi, Kartik
    Mendler, Michel
    Gish, Robert
    Loomba, Rohit
    Patton, Heather
    Kuo, Alexander
    Kono, Yuko
    [J]. GASTROENTEROLOGY, 2014, 146 (05) : S995 - S995