Utility of loop-mediated isothermal amplification as a point-of-care test in diagnosis of amoebic liver abscess

被引:1
|
作者
Handa, Dipti [1 ]
Gupta, Monica [1 ]
Lehl, Sarabmeet Singh [1 ]
Gupta, Amit [2 ]
Singh, Ram [1 ]
机构
[1] Govt Med Coll & Hosp, Dept Gen Med, Level 4,D Block, Chandigarh, India
[2] Deep Hosp, Dept Orthopaed, Ludhiana, Punjab, India
关键词
Entamoeba histolytica; amoebic liver abscess; loop-mediated isothermal amplification; reverse transcriptase polymerase chain reaction; enzyme linked immunosorbent assay; ENTAMOEBA-HISTOLYTICA; LAMP; ANTIGEN;
D O I
10.1177/00494755211018050
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Definitive diagnosis of amoebic liver abscess is challenging owing to the unavailability of sensitive commercial point-of-care molecular tests. The primary aim of our prospective diagnostic study was to compare available laboratory methods for the diagnosis of Entamoeba histolytica in clinical samples with loop-mediated isothermal amplification. We compared deoxyribonucleic acid (DNA) analysis methods, namely, loop-mediated isothermal amplification and reverse transcriptase polymerase chain reaction and enzyme-linked immunosorbent assay (ELISA) using pus, stool and blood samples from 200 patients with clinical and radiological diagnosis of amoebic liver abscess. Loop-mediated isothermal amplification had significantly higher sensitivity (88%) as compared to reverse transcriptase polymerase chain reaction (64%) and excellent specificity (100%).
引用
收藏
页码:488 / 491
页数:4
相关论文
共 50 条
  • [1] Evaluation of loop mediated isothermal amplification for the diagnosis of amoebic liver abscess
    Sehgal, R.
    Khunger, S.
    Duseja, A.
    Handa, D.
    Singh, R.
    [J]. INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2016, 45 : 378 - 378
  • [2] Loop-Mediated Isothermal Amplification as Point-of-Care Diagnosis for Neglected Parasitic Infections
    Avendano, Catalina
    Alfonso Patarroyo, Manuel
    [J]. INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2020, 21 (21) : 1 - 32
  • [3] Point-of-Care Diagnostic Platforms for Loop-Mediated Isothermal Amplification
    Atceken, Nazente
    Alseed, Muhammad Munzer
    Dabbagh, Sajjad Rahmani
    Yetisen, Ali K.
    Tasoglu, Savas
    [J]. ADVANCED ENGINEERING MATERIALS, 2023, 25 (08)
  • [4] Principles and Applications of Loop-Mediated Isothermal Amplification to Point-of-Care Tests
    Park, Jee-Woong
    [J]. BIOSENSORS-BASEL, 2022, 12 (10):
  • [5] Loop-mediated isothermal amplification for point-of-care diagnosis of viral respiratory tract infection in childhood
    Peters, R.
    Pfeil, J.
    Tabatabai, J.
    Grulich-Henn, J.
    Schnitzler, P.
    [J]. JOURNAL OF CLINICAL VIROLOGY, 2016, 82 : S51 - S51
  • [6] Loop-mediated isothermal amplification (LAMP) assay for rapid detection of Entamoeba histolytica in amoebic liver abscess
    Preeti Singh
    Bijay Ranjan Mirdha
    Vineet Ahuja
    Sundeep Singh
    [J]. World Journal of Microbiology and Biotechnology, 2013, 29 : 27 - 32
  • [7] Loop-mediated isothermal amplification (LAMP) assay for rapid detection of Entamoeba histolytica in amoebic liver abscess
    Singh, Preeti
    Mirdha, Bijay Ranjan
    Ahuja, Vineet
    Singh, Sundeep
    [J]. WORLD JOURNAL OF MICROBIOLOGY & BIOTECHNOLOGY, 2013, 29 (01): : 27 - 32
  • [8] POINT-OF-CARE DIAGNOSIS OF MALARIA BY FLUORESCENCE LOOP MEDIATED ISOTHERMAL AMPLIFICATION
    Lucchi, Naomi W.
    Demas, Allison
    Narayanan, Jothikumar
    Kabanywanyi, Abdunoor M.
    Sumari, Deborah
    Kachur, Patrick S.
    Barnwell, John W.
    Udhayakumar, Venkatachalam
    [J]. AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2010, 83 (05): : 285 - 286
  • [9] Rapid diagnosis of Plasmodium falciparum malaria using a point-of-care loop-mediated isothermal amplification device
    Puri, Madhu
    Kaur Brar, Harsimran
    Madan, Evanka
    Srinivasan, Rajesh
    Rawat, Kapil
    Gorthi, Sai Siva
    Kumari, Geeta
    Sah, Raj
    Ojha, Sashi Bhusan
    Panigrahi, Subhendu
    Dhangadamajhi, Gunanidhi
    Muthuswami, Rohini
    Singh, Shailja
    Madhubala, Rentala
    [J]. FRONTIERS IN CELLULAR AND INFECTION MICROBIOLOGY, 2022, 12
  • [10] RealAmp Loop-Mediated Isothermal Amplification as a Point-of-Care Test for Diagnosis of Malaria: Neither Too Close nor Too Far
    Goyal, Kapil
    Kaur, Hargobinder
    Sehgal, Alka
    Sehgal, Rakesh
    [J]. JOURNAL OF INFECTIOUS DISEASES, 2015, 211 (10): : 1686 - 1686